Analysis and Diagnostics of Adjacent and Nonadjacent Broken-Rotor-Bar Faults in Squirrel-Cage Induction Machines

In this paper, faults associated with the rotor of an induction machine are considered. More specifically, effects of adjacent and nonadjacent bar breakages on rotor fault diagnostics in squirrel-cage induction machines are studied. It is shown that some nonadjacent bar breakages may result in the masking of the commonly used fault indices and, hence, may lead to a possible misdiagnosis of the machine. A discussion of the possible scenarios of these breakages as well as some conclusions regarding the types of squirrel-cage induction machines (number of poles, number of squirrel-cage bars, etc.) that may be more prone to these nonadjacent types of failures are presented. This discussion is supported through both simulation and experimental results. It is also shown that secondary fault effects can be used to diagnose such nonadjacent bar breakages.

[1]  Shahin Hedayati Kia,et al.  A High-Resolution Frequency Estimation Method for Three-Phase Induction Machine Fault Detection , 2007, IEEE Transactions on Industrial Electronics.

[2]  Alberto Bellini,et al.  Quantitative Evaluation of Induction Motor Broken Bars By Means of Electric Signals Signatures , 2001 .

[3]  Nesimi Ertugrul,et al.  Induction machine on-line condition monitoring and fault diagnosis - a survey , 2003 .

[4]  R. Carlson,et al.  Inter-bar currents in the rotor of large three-phase cage induction motors: analysis and detection , 2003, 4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003..

[5]  Vlado Ostović,et al.  Dynamics of Saturated Electric Machines , 1989 .

[6]  B. Mirafzal,et al.  Effects of load magnitude on diagnosing broken bar faults in induction motors using the pendulous oscillation of the rotor magnetic field orientation , 2005, IEEE Transactions on Industry Applications.

[7]  I. D. Lomax Assessment of induction motor cage fatigue life , 1991 .

[8]  W. T. Thomson,et al.  Online current monitoring for fault diagnosis in inverter fed induction motors , 1988 .

[9]  G. B. Kliman,et al.  Noninvasive detection of broken rotor bars in operating induction motors , 1988 .

[10]  Behrooz Mirafzal,et al.  Induction machine broken-bar fault diagnosis using the rotor magnetic field space-vector orientation , 2004 .

[11]  V. Ostović A Method for Evaluation of Transient and Steady State Performance in Saturated Squirrel Cage Induction Machines , 1986, IEEE Transactions on Energy Conversion.

[12]  Bong-Hwan Kwon,et al.  Online Diagnosis of Induction Motors Using MCSA , 2006, IEEE Transactions on Industrial Electronics.

[13]  B. Mirafzal,et al.  On innovative methods of induction motor interturn and broken-bar fault diagnostics , 2006, IEEE Transactions on Industry Applications.

[14]  B. Mirafzal,et al.  Induction machine broken-bar fault diagnosis using the rotor magnetic field space-vector orientation , 2004, IEEE Transactions on Industry Applications.

[15]  Hamid A. Toliyat,et al.  Fault diagnosis of electrical machines-a review , 1999, IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272).

[16]  Christian Kral,et al.  Sequences of field-oriented control for the detection of faulty rotor bars in induction machines-the Vienna Monitoring Method , 1998, IEEE Trans. Ind. Electron..

[17]  Gennadi Y. Sizov Analysis, Modeling, and Diagnostics of Adjacent and Nonadjacent Broken Rotor Bars in Squirrel-Cage Induction Machines , 2007 .

[18]  Jafar Milimonfared,et al.  Interbar currents and axial fluxes in healthy and faulty induction motors , 2002 .

[19]  M. E. H. Benbouzid,et al.  What Stator Current Processing Based Technique to Use for Induction Motor Rotor Faults Diagnosis , 2002, IEEE Power Engineering Review.

[20]  A.H. Bonnett,et al.  Squirrel cage rotor options for AC induction motors , 2000, Conference Record of 2000 Annual Pulp and Paper Industry Technical Conference (Cat. No.00CH37111).

[21]  A. H. Bonnett,et al.  Analysis of rotor failures in squirrel-cage induction motors , 1988 .

[22]  V. Ostovic,et al.  A Simplified Approach to Magnetic Equivalent Circuit Modelling of Induction Machines , 1986, 1986 Annual Meeting Industry Applications Society.

[23]  F. Filippetti,et al.  Quantitative evaluation of induction motor broken bars by means of electrical signature analysis , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[24]  J. S. Hsu,et al.  Monitoring of defects in induction motors through air-gap torque observation , 1995 .

[25]  Nabeel A. O. Demerdash,et al.  Effects of broken bars/end-ring connectors and airgap eccentricities on ohmic and core losses of induction motors in ASDs using a coupled finite element-state space method , 2000 .

[26]  Behrooz Mirafzal Incipient fault diagnosis in squirrel-cage induction motors , 2005 .

[27]  W. T. Thomson,et al.  Current signature analysis to detect induction motor faults , 2001 .

[28]  E.L. Owen,et al.  Assessment of the Reliability of Motors in Utility Applications - Updated , 1986, IEEE Transactions on Energy Conversion.