Evaluation of stereoscopic medical video content on an autostereoscopic display for undergraduate medical education

Introduction: An increasing number of surgical procedures are performed in a microsurgical and minimally-invasive fashion. However, the performance of surgery, its possibilities and limitations become difficult to teach. Stereoscopic video has evolved from a complex production process and expensive hardware towards rapid editing of video streams with standard and HDTV resolution which can be displayed on portable equipment. This study evaluates the usefulness of stereoscopic video in teaching undergraduate medical students. Material and methods: From an earlier study we chose two clips each of three different microsurgical operations (tympanoplasty type III of the ear, endonasal operation of the paranasal sinuses and laser chordectomy for carcinoma of the larynx). This material was added by 23 clips of a cochlear implantation, which was specifically edited for a portable computer with an autostereoscopic display (PC-RD1-3D, SHARP Corp., Japan). The recording and synchronization of left and right image was performed at the University Hospital Aachen. The footage was edited stereoscopically at the Waseda University by means of our original software for non-linear editing of stereoscopic 3-D movies. Then the material was converted into the streaming 3-D video format. The purpose of the conversion was to present the video clips by a file type that does not depend on a television signal such as PAL or NTSC. 25 4th year medical students who participated in the general ENT course at Aachen University Hospital were asked to estimate depth clues within the six video clips plus cochlear implantation clips. Another 25 4th year students who were shown the material monoscopically on a conventional laptop served as control. Results: All participants noted that the additional depth information helped with understanding the relation of anatomical structures, even though none had hands-on experience with Ear, Nose and Throat operations before or during the course. The monoscopic group generally estimated resection depth to much lesser values than in reality. Although this was the case with some participants in the stereoscopic group, too, the estimation of depth features reflected the enhanced depth impression provided by stereoscopy. Conclusion: Following first implementation of stereoscopic video teaching, medical students who are inexperienced with ENT surgical procedures are able to reproduce depth information and therefore anatomically complex structures to a greater extent following stereoscopic video teaching. Besides extending video teaching to junior doctors, the next evaluation step will address its effect on the learning curve during the surgical training program.

[1]  T Langø,et al.  Stereoscopic navigation-controlled display of preoperative MRI and intraoperative 3D ultrasound in planning and guidance of neurosurgery: new technology for minimally invasive image-guided surgery approaches. , 2003, Minimally invasive neurosurgery : MIN.

[2]  H P Zenner,et al.  [Audiovisual telecommunication by multimedia technology in HNO medicine. ISDN--internet--ATM]. , 2000, HNO.

[3]  P K Plinkert,et al.  [Telemedicine: interaction between clinic and general practice]. , 2002, HNO.

[4]  B. Plinkert,et al.  Audiovisuelle Telekommunikation durch Multimediatechnologien in der HNO-Heilkunde ISDN – Internet – ATM , 2000, HNO.

[5]  Takashi Shibata,et al.  Development of software for editing of stereoscopic 3D movies , 2002, IS&T/SPIE Electronic Imaging.

[6]  K Radermacher,et al.  The influence of LCD shutter glasses on spatial perception in stereoscopic visualization. , 1996, Studies in health technology and informatics.

[7]  P. Plinkert,et al.  Telemedizin: Interaktionen zwischen Klinik und Praxis , 2002, HNO.

[8]  C Kaufmann,et al.  Telepresence surgery system enhances medical student surgery training. , 1999, Studies in health technology and informatics.

[9]  K Radermacher,et al.  Using human factor analysis and VR simulation techniques for the optimization of the surgical worksystem. , 1996, Studies in health technology and informatics.

[10]  K Radermacher,et al.  An automatic camera-holding system for gynecologic laparoscopy. , 2001, The Journal of the American Association of Gynecologic Laparoscopists.

[11]  K Radermacher,et al.  Three-dimensional versus two-dimensional video endoscopy. A clinical field study in laparoscopic application. , 1996, Studies in health technology and informatics.

[12]  Takashi Shibata,et al.  Production and evaluation of stereoscopic video presentation in surgical training , 2004, IS&T/SPIE Electronic Imaging.

[13]  Lothar Mühlbach,et al.  Telepresence in Videocommunications: A Study on Stereoscopy and Individual Eye Contact , 1995, Hum. Factors.