Short-Circuit Fault Tolerant Control of a Wind Turbine Driven Induction Generator Based on Sliding Mode Observers

The installed energy production capacity of wind turbines is growing intensely on a global scale, making the reliability of wind turbine subsystems of greater significance. However, many faults like Inter-Turn Short-Circuit (ITSC) may affect the turbine generator and quickly lead to a decline in supplied power quality. In this framework, this paper proposes a Sliding Mode Observer (SMO)-based Fault Tolerant Control (FTC) scheme for Induction Generator (IG)-based variable-speed grid-connected wind turbines. First, the dynamic models of the wind turbine subsystems were developed. The control schemes were elaborated based on the Maximum Power Point Tracking (MPPT) method and Indirect Rotor Flux Oriented Control (IRFOC) method. The grid control was also established by regulating the active and reactive powers. The performance of the wind turbine system and the stability of injected power to the grid were hence analyzed under both healthy and faulty conditions. The robust developed SMO-based Fault Detection and Isolation (FDI) scheme was proved to be fast and efficient for ITSC detection and localization.Afterwards, SMO were involved in scheming the FTC technique. Accordingly, simulation results assert the efficacy of the proposed ITSC FTC method for variable-speed wind turbines with faulty IG in protecting the subsystems from damage and ensuring continuous connection of the wind turbine to the grid during ITSC faults, hence maintaining power quality.

[1]  Andrew Kusiak,et al.  The prediction and diagnosis of wind turbine faults , 2011 .

[2]  Lin Chen,et al.  Sliding Mode Variable Structure Control of a Bearingless Induction Motor Based on a Novel Reaching Law , 2016 .

[3]  Halim Alwi,et al.  Design and Analysis of an Integral Sliding Mode Fault-Tolerant Control Scheme , 2012, IEEE Transactions on Automatic Control.

[4]  Takwa Sellami,et al.  Modal and harmonic analysis of three-dimensional wind turbine models , 2016 .

[5]  Marcin Wolkiewicz,et al.  Stator and Rotor Faults Monitoring of the Inverter-Fed Induction Motor Drive using State Estimators , 2013 .

[6]  Marcin Wolkiewicz,et al.  Online Stator Interturn Short Circuits Monitoring in the DFOC Induction-Motor Drive , 2016, IEEE Transactions on Industrial Electronics.

[7]  T. Habetler,et al.  An Impedance Identification Approach to Sensitive Detection and Location of Stator Turn-to-Turn Faults in a Closed-Loop Multiple-Motor Drive , 2011, IEEE Transactions on Industrial Electronics.

[8]  Sang Woo Kim,et al.  An Early Stage Interturn Fault Diagnosis of PMSMs by Using Negative-Sequence Components , 2017, IEEE Transactions on Industrial Electronics.

[9]  Halim Alwi,et al.  Fault Tolerant Control Schemes Using Integral Sliding Modes , 2016 .

[10]  Lie Xu,et al.  Direct active and reactive power control of DFIG for wind energy generation , 2006, IEEE Transactions on Energy Conversion.

[11]  Abdul Qayyum Khan,et al.  Observer-based FDI Schemes for Wind Turbine Benchmark , 2011 .

[12]  M. F. Cabanas,et al.  Detection of stator winding insulation failures: On-line and off-line tests , 2013, 2013 IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD).

[13]  Christopher Edwards,et al.  Adaptive Sliding-Mode-Observer-Based Fault Reconstruction for Nonlinear Systems With Parametric Uncertainties , 2008, IEEE Transactions on Industrial Electronics.

[14]  Sung-Hoon Ahn,et al.  Condition monitoring and fault detection of wind turbines and related algorithms: A review , 2009 .

[15]  Nicola Bianchi,et al.  Comparative study between the rotor flux oriented control and non-linear backstepping control of a five-phase induction motor drive – an experimental validation , 2016 .

[16]  Anis Sakly,et al.  PSO-based MPPT control of wind-driven Self-Excited Induction Generator for pumping system , 2016 .

[17]  Ming Cheng,et al.  Fault-Tolerant Sensorless Control of a Five-Phase FTFSCW-IPM Motor Based on a Wide-Speed Strong-Robustness Sliding Mode Observer , 2018, IEEE Transactions on Energy Conversion.

[18]  Osama A. Mohammed,et al.  Impact of Inter-Turn Short-Circuit Location on Induction Machines Parameters Through FE Computations , 2017 .

[19]  Yaoyu Li,et al.  A review of recent advances in wind turbine condition monitoring and fault diagnosis , 2009, 2009 IEEE Power Electronics and Machines in Wind Applications.

[20]  Mohamed Zribi,et al.  Sliding Mode Control of a Variable- Speed Wind Energy Conversion System Using a Squirrel Cage Induction Generator , 2017 .

[21]  T. Sellami,et al.  Sliding mode observer-based fault-detection of inter-turn short-circuit in induction motor , 2013, 14th International Conference on Sciences and Techniques of Automatic Control & Computer Engineering - STA'2013.

[22]  Christopher Edwards,et al.  Sliding Mode Observer-Based Fault Detection and Isolation , 2017 .

[23]  Steven X. Ding,et al.  A Survey of Fault Diagnosis and Fault-Tolerant Techniques—Part I: Fault Diagnosis With Model-Based and Signal-Based Approaches , 2015, IEEE Transactions on Industrial Electronics.

[24]  Elhoussin Elbouchikhi,et al.  Modeling and Simulation of a PMSG-based Marine Current Turbine System under Faulty Rectifier Conditions , 2017 .

[25]  Halim Alwi,et al.  Fault tolerant control using sliding modes with on-line control allocation , 2008, Autom..

[26]  Sanjeevikumar Padmanaban,et al.  An improved sensorless sliding mode control/adaptive observer of a five-phase permanent magnet synchronous motor drive , 2017 .