Characterization of the Fat Channel for Intra-Body Communication at R-Band Frequencies

In this paper, we investigate the use of fat tissue as a communication channel between in-body, implanted devices at R-band frequencies (1.7–2.6 GHz). The proposed fat channel is based on an anatomical model of the human body. We propose a novel probe that is optimized to efficiently radiate the R-band frequencies into the fat tissue. We use our probe to evaluate the path loss of the fat channel by studying the channel transmission coefficient over the R-band frequencies. We conduct extensive simulation studies and validate our results by experimentation on phantom and ex-vivo porcine tissue, with good agreement between simulations and experiments. We demonstrate a performance comparison between the fat channel and similar waveguide structures. Our characterization of the fat channel reveals propagation path loss of ∼0.7 dB and ∼1.9 dB per cm for phantom and ex-vivo porcine tissue, respectively. These results demonstrate that fat tissue can be used as a communication channel for high data rate intra-body networks.

[1]  O. SIAMJ.,et al.  A CLASS OF GLOBALLY CONVERGENT OPTIMIZATION METHODS BASED ON CONSERVATIVE CONVEX SEPARABLE APPROXIMATIONS∗ , 2002 .

[2]  Allen Taflove,et al.  Computational Electrodynamics the Finite-Difference Time-Domain Method , 1995 .

[3]  Thiemo Voigt,et al.  Human fat tissue: A microwave communication channel , 2017, 2017 First IEEE MTT-S International Microwave Bio Conference (IMBIOC).

[4]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[5]  Yeun-Ho Joung,et al.  Development of Implantable Medical Devices: From an Engineering Perspective , 2013, International neurourology journal.

[6]  Javier Reina-Tosina,et al.  Galvanic Coupling Transmission in Intrabody Communication: A Finite Element Approach , 2014, IEEE Transactions on Biomedical Engineering.

[7]  George M. Savage,et al.  An Ingestible Sensor for Measuring Medication Adherence , 2015, IEEE Transactions on Biomedical Engineering.

[8]  Thiemo Voigt,et al.  Reliability of the fat tissue channel for intra-body microwave communication , 2017, 2017 IEEE Conference on Antenna Measurements & Applications (CAMA).

[9]  M. Bendsøe,et al.  Topology Optimization: "Theory, Methods, And Applications" , 2011 .

[10]  D. Werber,et al.  Investigation of RF transmission properties of human tissues , 2006 .

[11]  Eddie Wadbro,et al.  Topology Optimisation of Wideband Coaxial-to-Waveguide Transitions , 2017, Scientific Reports.

[12]  Eddie Wadbro,et al.  Topology Optimization of Metallic Antennas , 2014, IEEE Transactions on Antennas and Propagation.

[13]  Michael Faulkner,et al.  Investigation of Galvanic-Coupled Intrabody Communication Using the Human Body Circuit Model , 2014, IEEE Journal of Biomedical and Health Informatics.

[14]  Bo Zhao,et al.  An Investigation on Ground Electrodes of Capacitive Coupling Human Body Communication , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[15]  Matthew Loy,et al.  ISM-Band and Short Range Device Regulatory Compliance Overview , 2005 .

[16]  Karoliina Koski,et al.  Antenna applications corner: Miniature implantable and wearable on-body antennas: Towards the new era of wireless body-centric systems , 2014 .

[17]  Gunar Schirner,et al.  Multi-Path Model and Sensitivity Analysis for Galvanic Coupled Intra-Body Communication Through Layered Tissue , 2015, IEEE Transactions on Biomedical Circuits and Systems.

[18]  K. Jenpanich,et al.  [Drug administration]. , 1976, Thai journal of nursing.

[19]  Chee Wee Kim,et al.  RF transmission power loss variation with abdominal tissues thicknesses for ingestible source , 2011, 2011 IEEE 13th International Conference on e-Health Networking, Applications and Services.

[20]  C Gabriel,et al.  Dielectric measurement: error analysis and assessment of uncertainty , 2006, Physics in medicine and biology.

[21]  Sudhakar K. Rao,et al.  Miniature implantable and wearable on-body antennas: towards the new era of wireless body-centric systems [antenna applications corner] , 2014, IEEE Antennas and Propagation Magazine.

[22]  Ilangko Balasingham,et al.  Experimental Path Loss Models for In-Body Communications Within 2.36-2.5 GHz , 2015, IEEE Journal of Biomedical and Health Informatics.

[23]  Niels Aage,et al.  Topology optimization of microwave waveguide filters , 2016 .

[24]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[25]  Ilangko Balasingham,et al.  Ultra-wideband statistical propagation channel model for implant sensors in the human chest , 2011 .

[26]  Lei Wang,et al.  Characterization of In-Body Radio Channels for Wireless Implants , 2017, IEEE Sensors Journal.

[27]  Jian Wang,et al.  Antenna Radiation Characteristics Optimization by a Hybrid Topological Method , 2017, IEEE Transactions on Antennas and Propagation.

[28]  Martin P. Bendsøe Topology Optimization , 2009, Encyclopedia of Optimization.

[29]  Harinath Garudadri,et al.  Channel Modeling of Miniaturized Battery-Powered Capacitive Human Body Communication Systems , 2017, IEEE Transactions on Biomedical Engineering.

[30]  German A. Alvarez-Botero,et al.  Characterization and Modeling of the Capacitive HBC Channel , 2015, IEEE Transactions on Instrumentation and Measurement.

[31]  Eddie Wadbro,et al.  Topology optimization of compact wideband coaxial-to-waveguide transitions with minimum-size control , 2018 .

[32]  F. Shimabukuro,et al.  The Essence of Dielectric Waveguides , 2008 .

[33]  Thiemo Voigt,et al.  Intra-body microwave communication through adipose tissue , 2017, Healthcare technology letters.

[34]  Thiemo Voigt,et al.  Data Packet Transmission Through Fat Tissue for Wireless IntraBody Networks , 2017, IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology.

[35]  Oktay Akkus,et al.  Evaluation of Skin and Subcutaneous Adipose Tissue Thickness for Optimal Insulin Injection , 2012 .

[36]  ダーリー、イアン,et al.  Implantable medical devices , 2006 .