An Ergonomic Evaluation of the Extravehicular Mobility Unit (EMU) Spacesuit Hard Upper Torso (HUT) Size Effect on Mobility, Strength, and Metabolic Performance

Introduction: The objective of this project was to develop a comprehensive methodology to assess the suit fit and performance differences between a nominally sized extravehicular mobility unit (EMU) spacesuit and a nominal +1 (plus) sized EMU. Method: This study considered a multitude of evaluation metrics including 3D clearances and pressure point mapping to quantify potential issues associated with using off-nominal suit sizes. Results: There were minimal differences with using a plus suit size. Discussion: Analysis of the results indicates that future suit size evaluations should consider this ergonomic approach to understand and mitigate potential suit fit and performance issues.