Spiral CT of the pancreas

Purpose: to compare the value of a retrospective targeted high-resolution spiral CT to the standard reconstruction technique in the assessment of pancreatic diseases Material and Methods: Spiral CT pancreatic images of a standard-size reconstruction protocol were compared prospectively with those of a retrospective targeted high-spatial-resolution reconstruction protocol in 30 patients. Prior to clinical evaluation, a phantom study was performed to evaluate the spatial resolution and signal-to-noise ratio of both protocols Results: the high-resolution protocol achieved a good signal-to-noise ratio with acceptable spatial resolution. Phantom studies revealed increased image noise (+17%) with an increase in spatial resolution (+100%). in patients studied with the high-resolution protocol, the increase in noise was not significant but there was a marked improvement in the definition of small details Conclusion: Images obtained with a targeted high-spatial-resolution reconstruction protocol showed superior lesion definition and vascular opacification compared with those obtained with a standard-size reconstruction protocol. This technique may have potential in the evaluation of small pancreatic abnormalities

[1]  C. Charnsangavej,et al.  Helical CT angiography with multiplanar reformation: techniques and clinical applications. , 1995, Radiographics : a review publication of the Radiological Society of North America, Inc.

[2]  R. Spillane,et al.  High-resolution CT of the lungs. , 1993, American family physician.

[3]  D E Dupuy,et al.  Spiral CT of the pancreas. , 1992, Radiology.

[4]  T. Ishigaki,et al.  Mucin-producing pancreatic tumor: CT findings and histopathologic correlation. , 1992, Radiology.

[5]  J. Remy,et al.  Assessment of diffuse infiltrative lung disease: comparison of conventional CT and high-resolution CT. , 1991, Radiology.

[6]  D Blume,et al.  Pulmonary nodule: evaluation with spiral volumetric CT. , 1991, Radiology.

[7]  W. Kalender,et al.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. , 1990, Radiology.

[8]  D L Robinson,et al.  Acute pancreatitis: value of CT in establishing prognosis. , 1990, Radiology.

[9]  P. Freeny Radiology of the pancreas. , 1990, Current opinion in radiology.

[10]  C A Rohrmann,et al.  CT of the extrahepatic bile ducts: wall thickness and contrast enhancement in normal and abnormal ducts. , 1990, AJR. American journal of roentgenology.

[11]  N L Müller,et al.  High-spatial-frequency (bone) algorithm improves quality of standard CT of the thorax. , 1989, AJR. American journal of roentgenology.

[12]  P. Freeny Radiology of the pancreas: two decades of progress in imaging and intervention. , 1988, AJR. American journal of roentgenology.

[13]  E. Zerhouni,et al.  The pulmonary nodule. , 1988, Seminars in ultrasound, CT, and MR.

[14]  L. Traverso,et al.  Pancreatic ductal adenocarcinoma: diagnosis and staging with dynamic CT. , 1988, Radiology.

[15]  G Gamsu,et al.  High-resolution CT of the lungs: an optimal approach. , 1987, Radiology.

[16]  R. Jeffrey,et al.  Pancreatic abscess: predictive value of early abdominal CT. , 1987, Radiology.