An Ankle-Foot Prosthesis Emulator Capable of Modulating Center of Pressure

Objective: Several powered ankle-foot prostheses have demonstrated moderate reductions in energy expenditure by restoring pushoff work in late stance or by assisting with balance. However, it is possible that center of pressure trajectory modulation could provide even further improvements in user performance. Here, we describe the design of a prosthesis emulator with two torque-controlled forefoot digits and a torque-controlled heel digit. Independent actuation of these three digits can modulate the origin and magnitude of the total ground reaction force vector. Methods: The emulator was designed to be compact and lightweight while exceeding the range of motion and torque requirements of the biological ankle during walking. We ran a series of tests to determine torque-measurement accuracy, closed-loop torque control bandwidth, torque-tracking error, and center of pressure control accuracy. Results: Each of the three digits demonstrated less than 2 Nm of RMS torque measurement error, a 90% rise time of 19 ms, and a bandwidth of 33 Hz. The untethered end-effector has a mass of 1.2 kg. During walking trials, the emulator demonstrated less than 2 Nm of RMS torque-tracking error and was able to maintain full digit ground contact for 56% of stance. In fixed, standing, and walking conditions, the emulator was able to control center of pressure along a prescribed pattern with RMS errors of about 10% the length of the pattern. Conclusion: The proposed emulator system meets all design criteria and can effectively modulate center of pressure and ground reaction force magnitude. Significance: This emulator system will enable rapid development of controllers designed to enhance user balance and reduce user energy expenditure. Experiments conducted using this emulator could identify beneficial control behaviors that can be implemented on autonomous devices, thus improving mobility and quality of life of individuals with amputation.

[1]  Myunghee Kim,et al.  Step-to-Step Ankle Inversion/Eversion Torque Modulation Can Reduce Effort Associated with Balance , 2017, Front. Neurorobot..

[2]  Neville Hogan,et al.  An Emulator System for Developing Improved Elbow-Prosthesis Designs , 1987, IEEE Transactions on Biomedical Engineering.

[3]  Shuguang Huang,et al.  Design and Evaluation of a Passive Ankle Prosthesis With Powered Push-Off , 2016 .

[4]  Juanjuan Zhang,et al.  Design of two lightweight, high-bandwidth torque-controlled ankle exoskeletons , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[5]  Steven H. Collins,et al.  An experimental robotic testbed for accelerated development of ankle prostheses , 2013, 2013 IEEE International Conference on Robotics and Automation.

[6]  T.G. Sugar,et al.  SPARKy 3: Design of an active robotic ankle prosthesis with two actuated degrees of freedom using regenerative kinetics , 2008, 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics.

[7]  Shawn J. Scott,et al.  Gait characteristics of individuals with transtibial amputations walking on a destabilizing rock surface. , 2012, Gait & posture.

[8]  M. R. Hawes,et al.  Quantitative morphology of the human foot in a North American population. , 1994, Ergonomics.

[9]  K. Newell,et al.  Aging and the complexity of center of pressure in static and dynamic postural tasks , 2016, Neuroscience Letters.

[10]  Jonathan B Dingwell,et al.  Dynamic stability of superior vs. inferior body segments in individuals with transtibial amputation walking in destabilizing environments. , 2014, Journal of biomechanics.

[11]  R. Brent Gillespie,et al.  A Fundamental Linear Systems Conflict Between Performance and Passivity in Haptic Rendering , 2011, IEEE Transactions on Robotics.

[12]  J. Donelan,et al.  Mechanical work for step-to-step transitions is a major determinant of the metabolic cost of human walking. , 2002, The Journal of experimental biology.

[13]  Michael Goldfarb,et al.  Preliminary evaluation of a walking controller for a powered ankle prosthesis , 2014, 2013 IEEE International Conference on Robotics and Automation.

[14]  Elliott J. Rouse,et al.  Correction to “The VSPA Foot: A Quasi-Passive Ankle-Foot Prosthesis With Continuously Variable Stiffness” , 2018 .

[15]  Joshua M. Caputo,et al.  Increasing ankle push-off work with a powered prosthesis does not necessarily reduce metabolic rate for transtibial amputees. , 2016, Journal of biomechanics.

[16]  S. Collins,et al.  Recycling Energy to Restore Impaired Ankle Function during Human Walking , 2010, PloS one.

[17]  Mohammad Rastgaar,et al.  Design and Preliminary Evaluation of a Two DOFs Cable-Driven Ankle–Foot Prosthesis with Active Dorsiflexion–Plantarflexion and Inversion–Eversion , 2016, Front. Bioeng. Biotechnol..

[18]  L. V. D. van der Woude,et al.  Can external lateral stabilization reduce the energy cost of walking in persons with a lower limb amputation? , 2014, Gait & posture.

[19]  Kathryn Ziegler-Graham,et al.  Estimating the prevalence of limb loss in the United States: 2005 to 2050. , 2008, Archives of physical medicine and rehabilitation.

[20]  Marco Cempini,et al.  Design, development, and bench-top testing of a powered polycentric ankle prosthesis , 2017, 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[21]  Rachel W Jackson,et al.  Human-in-the-loop optimization of exoskeleton assistance during walking , 2017, Science.

[22]  Shawn J. Scott,et al.  Frontal plane dynamic margins of stability in individuals with and without transtibial amputation walking on a loose rock surface. , 2013, Gait & posture.

[23]  J. Veneman Design and evaluation of the gait rehabilitation robot LOPES , 2007 .

[24]  W. Polomski,et al.  The energy cost for the step-to-step transition in amputee walking. , 2009, Gait & posture.

[25]  David A. Winter,et al.  Human balance and posture control during standing and walking , 1995 .

[26]  Ilse Jonkers,et al.  Successful Preliminary Walking Experiments on a Transtibial Amputee Fitted with a Powered Prosthesis , 2009, Prosthetics and orthotics international.

[27]  Steven H Collins,et al.  Once-per-step control of ankle-foot prosthesis push-off work reduces effort associated with balance during walking , 2015, Journal of NeuroEngineering and Rehabilitation.

[28]  Rachel W Jackson,et al.  An experimental comparison of the relative benefits of work and torque assistance in ankle exoskeletons. , 2015, Journal of applied physiology.

[29]  Joshua M. Caputo,et al.  The influence of push-off timing in a robotic ankle-foot prosthesis on the energetics and mechanics of walking , 2015, Journal of NeuroEngineering and Rehabilitation.

[30]  Hugh M. Herr,et al.  Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits , 2008, Neural Networks.

[31]  Daniel P Ferris,et al.  An improved powered ankle-foot orthosis using proportional myoelectric control. , 2006, Gait & posture.

[32]  Hugh M. Herr,et al.  An ankle-foot emulation system for the study of human walking biomechanics , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[33]  Daniel Vélez Día,et al.  Biomechanics and Motor Control of Human Movement , 2013 .

[34]  Steven H Collins,et al.  A universal ankle-foot prosthesis emulator for human locomotion experiments. , 2014, Journal of biomechanical engineering.

[35]  Chien Chern Cheah,et al.  Torque Control in Legged Locomotion , 2017 .

[36]  W. Miller,et al.  The influence of falling, fear of falling, and balance confidence on prosthetic mobility and social activity among individuals with a lower extremity amputation. , 2001, Archives of physical medicine and rehabilitation.

[37]  A. Hof,et al.  Control of lateral balance in walking. Experimental findings in normal subjects and above-knee amputees. , 2007, Gait & posture.

[38]  Bram Vanderborght,et al.  Passive Ankle-Foot Prosthesis Prototype with Extended Push-Off , 2013 .

[39]  Hartmut Geyer,et al.  Control of a Powered Ankle–Foot Prosthesis Based on a Neuromuscular Model , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[40]  Jaap H van Dieën,et al.  Stepping Asymmetry Among Individuals With Unilateral Transtibial Limb Loss Might Be Functional in Terms of Gait Stability , 2014, Physical Therapy.

[41]  R W Mann,et al.  An electrohydraulic knee-torque controller for a prosthesis simulator. , 1977, Journal of biomechanical engineering.

[42]  J. Paysant,et al.  Influence of terrain on metabolic and temporal gait characteristics of unilateral transtibial amputees. , 2006, Journal of rehabilitation research and development.

[43]  Daniel P. Ferris,et al.  An Experimental Powered Lower Limb Prosthesis Using Proportional Myoelectric Control , 2014 .

[44]  Tianjian Chen,et al.  An ankle-foot prosthesis emulator with control of plantarflexion and inversion-eversion torque , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[45]  Alena M. Grabowski,et al.  Bionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation , 2012, Proceedings of the Royal Society B: Biological Sciences.

[46]  Steven H Collins,et al.  A simple method for calibrating force plates and force treadmills using an instrumented pole. , 2009, Gait & posture.

[47]  Andrew K. LaPre,et al.  Preliminary study of a robotic foot-ankle prosthesis with active alignment , 2017, 2017 International Conference on Rehabilitation Robotics (ICORR).