Effect of electrode dimensions on motor unit potentials.

Different effects of longitudinal and transversal electrode dimensions on nerve or muscle single fibre action potentials detected monopolarly, were reported in the literature. The results were contradictory. We studied motor unit potentials (MUPs) detected at a large distance (typical of surface recording) on the basis of a mathematical model without source simplification. The MUPs were calculated as a single convolution of the first temporal derivative of a realistic intracellular action potential and MU impulse response. The spatial averaging of the MUPs by rectangular plate electrodes was performed through analytical integration of the MU impulse response over the electrode area. The effects of longitudinal dimension of the electrode were stronger than those of a transversal one. The effects were distance dependent. The longitudinal dimension of the electrode influenced the main phases (that reflected the excitation origin and propagation) more than the terminal phases (that reflected the excitation extinction at the muscle fibers' ends). This was due to differences in the character of the potential fields (quadrupole or dipole) during generation of individual MUP phases. It was shown that the relative weight of the individual MUP phases could be stressed or suppressed by a proper choice of electrode dimensions, position and orientation.

[1]  W. van der Kamp,et al.  CMAP variability as a function of electrode site and size , 1995, Muscle & nerve.

[2]  Wee As,et al.  Relationship between the size of the recording electrodes and morphology of the compound muscle action potentials , 1990 .

[3]  J Ekstedt,et al.  How the size of the needle electrode leading-off surface influences the shape of the single muscle fibre action potential in electromyography. , 1973, Computer programs in biomedicine.

[4]  N. Dimitrova,et al.  Model of the extracellular potential field of a single striated muscle fibre. , 1974, Electromyography and clinical neurophysiology.

[5]  Z C Lateva,et al.  Anatomical and electrophysiological determinants of the human thenar compound muscle action potential , 1996, Muscle & nerve.

[6]  G. C. Barker Noise connected with electrode processes , 1969 .

[7]  J. Cram,et al.  Introduction to Surface Electromyography , 1998 .

[8]  Robert Plonsey,et al.  Dependence of Scalar Potential Measurements on Electrode Geometry , 1965 .

[9]  F BUCHTHAL,et al.  Action potential parameters in normal human muscle and their dependence on physical variables. , 1954, Acta physiologica Scandinavica.

[10]  Z C Lateva,et al.  The physiological origin of the slow afterwave in muscle action potentials. , 1997, Electroencephalography and clinical neurophysiology.

[11]  J. van Dijk,et al.  Large electrodes improve nerve conduction repeatability in controls as well as in patients with diabetic neuropathy , 1996, Muscle & nerve.

[12]  G V Dimitrov,et al.  Bipolar recording of potentials generated by excitable fibres in a volume conductor. , 1977, Agressologie: revue internationale de physio-biologie et de pharmacologie appliquees aux effets de l'agression.

[13]  Z C Lateva,et al.  Influence of the fiber length on the power spectra of single muscle fiber extracellular potentials. , 1991, Electromyography and clinical neurophysiology.

[14]  S D Nandedkar,et al.  Recording characteristics of the surface EMG electrodes , 1994, Muscle & nerve.

[15]  D Kosarov,et al.  Volume conduction of the potentials from separate motor units in human muscle. , 1972, Electromyography and clinical neurophysiology.

[16]  P. Rosenfalck Intra- and extracellular potential fields of active nerve and muscle fibres. A physico-mathematical analysis of different models. , 1969, Acta physiologica Scandinavica. Supplementum.

[17]  G V Dimitrov,et al.  Fundamentals of power spectra of extracellular potentials produced by a skeletal muscle fibre of finite length. Part I: Effect of fibre anatomy. , 1998, Medical engineering & physics.

[18]  N. Dimitrova,et al.  Precise and fast calculation of the motor unit potentials detected by a point and rectangular plate electrode. , 1998, Medical engineering & physics.

[19]  G. Loeb,et al.  Electromyography for Experimentalists , 1986 .

[20]  A. Nightingale,et al.  Background noise in electromyography. , 1959, Physics in medicine and biology.

[21]  G V Dimitrov,et al.  Influence of the afterpotentials on the shape and magnitude of the extracellular potentials generated under activation of excitable fibres. , 1979, Electromyography and clinical neurophysiology.

[22]  R Schoonhoven,et al.  On the optimal choice of a recording electrode in electroneurography. , 1984, Electroencephalography and clinical neurophysiology.