A novel technique for the measurement of disruption in high‐pressure homogenization: Studies on E. coli containing recombinant inclusion bodies

The high‐pressure homogenization of Escherichia coli, strain JM101, containing inclusion bodies of recombinant porcine somatotropin was investigated. A novel technique employing an analytical disc centrifuge was used to monitor the disruption. This a direct technique which measures cell disintegration rather than soluble protein release. The technique is particularly suited to measurements where the disruption approaches 100%. The disk centrifuge provides a size distribution of the homogenate, and furnishes evidence for the preferential disruption of larger cells. For E. coli containing inclusion bodies, and increase in the cell feed concentration from 145 g/L (wet weight) to 330 g/L resulted is poorer homogenization. Poorer disruption was also obtained by lowering the feed temperature from 20°C to 5°C. Only slight variations in performance were obtained by increasing the feed pH from 7.5 to 9.0 or by storing the feed at 4°C for 24 h prior to disruption. Comparison with uninduced E. coli strain JM101, showed that the disruption obtained is higher for bacteria containing a recombinant inclusion body.

[1]  J. Kane,et al.  Formation of recombinant protein inclusion bodies in Escherichia coli , 1988 .

[2]  M. M. Bradford A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. , 1976, Analytical biochemistry.

[3]  P. D. Vize,et al.  Spacer alterations which increase the expression of porcine growth hormone in E. coli , 1987, FEBS letters.

[4]  C. Rha,et al.  Disintegration of dried yeast cells and its effect on protein extractability, sedimentation property, and viscosity of the cell suspension , 1979 .

[5]  E. Margoliash,et al.  Preparation of cytochrome c2 from Rhodospirillum rubrum. , 1976, Analytical biochemistry.

[6]  M. Kula,et al.  Purification of Proteins and the Disruption of Microbial Cells , 1987 .

[7]  T. Hammond,et al.  A hydrodynamic mechanism for the disintegration of Saccharomyces cerevisiae in an industrial homogenizer , 1975 .

[8]  O. H. Lowry,et al.  Protein measurement with the Folin phenol reagent. , 1951, The Journal of biological chemistry.

[9]  L. Oppenheimer Interpretation of disk centrifuge data , 1983 .

[10]  C. B. Orsborn,et al.  Reactor properties of a high‐speed bead mill for microbial cell rupture , 1979 .

[11]  J. Brookman,et al.  Mechanism of cell disintegration in a high pressure homogenizer , 1974 .

[12]  C. W. Robinson,et al.  Disruption of native and recombinant Escherichia coli in a high‐pressure homogenizer , 1989, Biotechnology and bioengineering.

[13]  M. Hoare,et al.  Size and Density of Protein Inclusion Bodies , 1986, Bio/Technology.

[14]  C. Robinson,et al.  Disruption of Candida utilis cells in high pressure flow devices * , 1981 .

[15]  D. Fairhurst,et al.  HIGH RESOLUTION PARTICLE SIZE ANALYSIS OF COATING MATERIALS , 1991 .

[16]  I. Bogle,et al.  Sizing Biological Samples by Photosedimentation Techniques , 1990, Biotechnology progress.

[17]  Peter Dunnill,et al.  Investigation of the unit operations involved in the continuous flow isolation of β‐galactosidase from Escherichia coli , 1978 .