Investigation of various voltage sag analyses in wind farm through SVC

In this study, the systems connect wind farm various voltage sag wind Farm DC link voltage, system buses voltage examined. For study of various transient stability 7.2 MVAr Static Var Compensator (SVC) is used. In the wind farm examined, 6 MW Double Feed Induction Generator (DFIG) is used. Also it examined 3 phase fault, induction motor, both 3 phase fault and induction motor together in wind farm. The results achieved have proved that SVC yield good results when used in terms of transient stability of the system., SVC was found to be effective and successful for eliminating instability in a very short period of time.

[1]  Suttichai Premrudeepreechacharn,et al.  Power system with multi-type FACTS devices states estimation based on predictor-corrector interior point algorithm , 2009 .

[2]  Hong Shen,et al.  The coordination control of voltage and reactive power between wind turbines and SVC in large scale wind farm , 2010, 2010 International Conference on Power System Technology.

[3]  D. Aouzellag,et al.  Contribution to the improvement of voltage profile in electrical network with wind generator using SVC device , 2010 .

[4]  B. Fox,et al.  Grid Integration of Wind Farms Using SVC and STATCOM , 2006, Proceedings of the 41st International Universities Power Engineering Conference.

[5]  N. Magaji,et al.  Design of power oscillation damping controller for SVC device , 2008, 2008 IEEE 2nd International Power and Energy Conference.

[6]  Jon Are Suul,et al.  Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC , 2008, IEEE Transactions on Power Electronics.

[7]  Niels Kjølstad Poulsen,et al.  Modelling and transient stability of large wind farms , 2003 .

[8]  Ali Daneshi,et al.  Impact of SVC and STATCOM on power system including a wind farm , 2010, 2010 9th International Conference on Environment and Electrical Engineering.

[9]  N. Senthil Kumar,et al.  Impact of FACTS controllers on the stability of power systems connected with doubly fed induction generators , 2011 .

[10]  A. Mullane,et al.  Modeling of the wind turbine with a doubly fed induction generator for grid integration studies , 2006, IEEE Transactions on Energy Conversion.

[11]  Xiangning Xiao,et al.  Enhancement voltage stability of wind farm access to power grid by novel SVC , 2009, 2009 4th IEEE Conference on Industrial Electronics and Applications.

[12]  A. Ozturk,et al.  Investigation of the control voltage and reactive power in wind farm load bus by statcom and SVC , 2009, 2009 International Conference on Electrical and Electronics Engineering - ELECO 2009.

[13]  Surya Santoso,et al.  Increasing wind farm transient stability by dynamic reactive compensation: Synchronous-machine-based ESS versus SVC , 2010, IEEE PES General Meeting.

[14]  S. Afsharnia,et al.  Improvement of Voltage Stability in Wind Farm Connection to distribution Network Using FACTS Devices , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[15]  Morteza Alizadeh,et al.  Effect of Static VAR Compensator to improve an induction motor's performance , 2010, 2010 Conference Proceedings IPEC.