Comparison of different procedures to predict the volt-time curves of 15 kV insulators
暂无分享,去创建一个
[1] P. Chowdhuri,et al. Volt-time characteristics of short air gaps under nonstandard lightning voltage waves , 1997, IEEE Power Engineering Review.
[2] M. Darveniza,et al. The generalized integration method for predicting impulse volt-time characteristics for non-standard wave shapes-a theoretical basis , 1988 .
[3] C. Mazzetti,et al. Breakdown characteristics of air spark-gaps stressed by standard and short-tail lightning impulses: Experimental results and comparison with time to sparkover models , 2007 .
[4] C. Mazzetti,et al. Optimal selection of disruptive effect models parameters for the reproduction of MV insulators volt-time characteristics under standard and non standard lightning impulses , 2007, 2007 IEEE Lausanne Power Tech.
[5] C. Mazzetti,et al. Behavior of MV Insulators Under Lightning-Induced Overvoltages: Experimental Results and Reproduction of Volt–Time Characteristics by Disruptive Effect Models , 2010, IEEE Transactions on Power Delivery.
[6] A. Piantini,et al. A Scale Model for the Study of the LEMP Response of Complex Power Distribution Networks , 2007, IEEE Transactions on Power Delivery.
[7] M. Ianoz,et al. Lightning-induced voltages on overhead lines , 1993 .
[8] A. Carrus. An inductance on the Marx generator tail branch-new technique for high efficiency laboratory reproduction of short time to half value lightning impulses , 1989 .
[9] C. Mazzetti,et al. Evaluation of the performance of different methods for estimating the parameters of the disruptive effect model — Application to 15 kV insulators , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.
[10] C. Mazzetti,et al. A proposal for the prediction of the volt-time curves of MV insulators based on the Disruptive Effect Model , 2015, 2015 International Symposium on Lightning Protection (XIII SIPDA).
[11] Alexandre Piantini,et al. Analysis of different procedures for the application of the Disruptive Effect Model to distribution insulators subject to short tail lightning impulses , 2014 .
[12] A. Piantini,et al. Lightning-Induced Voltages on Overhead Lines—Application of the Extended Rusck Model , 2009, IEEE Transactions on Electromagnetic Compatibility.
[13] R. L. Witzke,et al. Co-ordination of Lightning Arrester Location with Transformer Insulation Level , 1950, Transactions of the American Institute of Electrical Engineers.
[14] A. Carrus,et al. Very Short Tailed Lightning Double Exponential Wave Generation Techniques Based on Marx Circuit Standard Configurations , 1984, IEEE Transactions on Power Apparatus and Systems.
[15] M. Ianoz,et al. Influence of a lossy ground on lightning-induced voltages on overhead lines , 1996 .
[16] R. L. Witzke,et al. Surge Protection of Cable-Connected Equipment , 1950, Transactions of the American Institute of Electrical Engineers.
[17] Kunihiko Miyake,et al. Advanced Observations of Lightning Induced Voltage on Power Distribution Lines (II) , 1986, IEEE Power Engineering Review.
[18] V. Cooray,et al. Shapes and amplitudes of the initial peaks of lightning-induced voltage in power lines over finitely conducting earth: Theory and comparison with experiment , 1986 .