Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: Phantom studies.

PURPOSE Recent advances in compressed sensing (CS) enable accurate CT image reconstruction from highly undersampled and noisy projection measurements, due to the sparsifiable feature of most CT images using total variation (TV). These novel reconstruction methods have demonstrated advantages in clinical applications where radiation dose reduction is critical, such as onboard cone-beam CT (CBCT) imaging in radiation therapy. The image reconstruction using CS is formulated as either a constrained problem to minimize the TV objective within a small and fixed data fidelity error, or an unconstrained problem to minimize the data fidelity error with TV regularization. However, the conventional solutions to the above two formulations are either computationally inefficient or involved with inconsistent regularization parameter tuning, which significantly limit the clinical use of CS-based iterative reconstruction. In this paper, we propose an optimization algorithm for CS reconstruction which overcomes the above two drawbacks. METHODS The data fidelity tolerance of CS reconstruction can be well estimated based on the measured data, as most of the projection errors are from Poisson noise after effective data correction for scatter and beam-hardening effects. We therefore adopt the TV optimization framework with a data fidelity constraint. To accelerate the convergence, we first convert such a constrained optimization using a logarithmic barrier method into a form similar to that of the conventional TV regularization based reconstruction but with an automatically adjusted penalty weight. The problem is then solved efficiently by gradient projection with an adaptive Barzilai-Borwein step-size selection scheme. The proposed algorithm is referred to as accelerated barrier optimization for CS (ABOCS), and evaluated using both digital and physical phantom studies. RESULTS ABOCS directly estimates the data fidelity tolerance from the raw projection data. Therefore, as demonstrated in both digital Shepp-Logan and physical head phantom studies, consistent reconstruction performances are achieved using the same algorithm parameters on scans with different noise levels and/or on different objects. On the contrary, the penalty weight in a TV regularization based method needs to be fine-tuned in a large range (up to seven times) to maintain the reconstructed image quality. The improvement of ABOCS on computational efficiency is demonstrated in the comparisons with adaptive-steepest-descent-projection-onto-convex-sets (ASD-POCS), an existing CS reconstruction algorithm also using constrained optimization. ASD-POCS alternatively minimizes the TV objective using adaptive steepest descent (ASD) and the data fidelity error using projection onto convex sets (POCS). For similar image qualities of the Shepp-Logan phantom, ABOCS requires less computation time than ASD-POCS inMATLAB by more than one order of magnitude. CONCLUSIONS We propose ABOCS for CBCT reconstruction. As compared to other published CS-based algorithms, our method has attractive features of fast convergence and consistent parameter settings for different datasets. These advantages have been demonstrated on phantom studies.

[1]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[2]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[3]  J. Borwein,et al.  Two-Point Step Size Gradient Methods , 1988 .

[4]  J. Hsieh,et al.  An iterative approach to the beam hardening correction in cone beam CT. , 2000, Medical physics.

[5]  Chye Hwang Yan,et al.  Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction , 2000, IEEE Transactions on Medical Imaging.

[6]  D. Kopans,et al.  Tomographic mammography using a limited number of low-dose cone-beam projection images. , 2003, Medical physics.

[7]  Stephen J. Wright,et al.  Primal-Dual Interior-Point Methods , 1997 .

[8]  TU-D-I-611-06: A Direct, Empirical Method for X-Ray Scatter Correction in Digital Radiography and Cone-Beam CT , 2005 .

[9]  Jeffrey H. Siewerdsen,et al.  TU‐D‐I‐611‐04: Intensity‐Modulated Cone‐Beam CT for Patient‐Specific Distribution of SNR , 2005 .

[10]  Bin Zhou,et al.  Gradient Methods with Adaptive Step-Sizes , 2006, Comput. Optim. Appl..

[11]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.

[12]  Lei Zhu,et al.  Scatter Correction Method for X-Ray CT Using Primary Modulation: Theory and Preliminary Results , 2006, IEEE Transactions on Medical Imaging.

[13]  E. Sidky,et al.  Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT , 2009, 0904.4495.

[14]  Steve B. Jiang,et al.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. , 2007, Medical physics.

[15]  Mário A. T. Figueiredo,et al.  Gradient Projection for Sparse Reconstruction: Application to Compressed Sensing and Other Inverse Problems , 2007, IEEE Journal of Selected Topics in Signal Processing.

[16]  Rebecca Fahrig,et al.  A short-scan reconstruction for cone-beam CT using shift-invariant FBP and equal weighting. , 2007, Medical physics.

[17]  D. Brenner,et al.  Computed tomography--an increasing source of radiation exposure. , 2007, The New England journal of medicine.

[18]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[19]  Wotao Yin,et al.  Bregman Iterative Algorithms for (cid:2) 1 -Minimization with Applications to Compressed Sensing ∗ , 2008 .

[20]  Nelson Lam,et al.  Radiation dose from cone beam computed tomography for image-guided radiation therapy. , 2008, International Journal of Radiation Oncology, Biology, Physics.

[21]  Lei Xing,et al.  Using total-variation regularization for intensity modulated radiation therapy inverse planning with field-specific numbers of segments , 2008, Physics in medicine and biology.

[22]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[23]  Lei Zhu,et al.  Noise suppression in scatter correction for cone-beam CT. , 2009, Medical physics.

[24]  Lei Zhu,et al.  Search for IMRT inverse plans with piecewise constant fluence maps using compressed sensing techniques. , 2009, Medical physics.

[25]  Jie Tang,et al.  Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms , 2009, Physics in medicine and biology.

[26]  Lei Zhu,et al.  Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images. , 2010, Medical physics.

[27]  N. R. Bennett,et al.  Scatter correction method for x-ray CT using primary modulation: phantom studies. , 2010, Medical physics.

[28]  Steve B. Jiang,et al.  GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation , 2010 .

[29]  Lei Zhu,et al.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order methoda). , 2010, Medical physics.

[30]  Kai Yang,et al.  Noise variance analysis using a flat panel x-ray detector: a method for additive noise assessment with application to breast CT applications. , 2010, Medical physics.

[31]  Steve B. Jiang,et al.  GPU-based Fast Low Dose Cone Beam CT Reconstruction via Total Variation , 2010, 1001.0599.

[32]  Lei Zhu,et al.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan. , 2011, Medical physics.

[33]  Xiaochuan Pan,et al.  A constrained, total-variation minimization algorithm for low-intensity x-ray CT. , 2010, Medical physics.

[34]  Steve B. Jiang,et al.  GPU-based iterative cone-beam CT reconstruction using tight frame regularization , 2010, Physics in medicine and biology.

[35]  Jing Wang,et al.  Inverse determination of the penalty parameter in penalized weighted least-squares algorithm for noise reduction of low-dose CBCT. , 2011, Medical physics.

[36]  Jin Sung Kim,et al.  Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT. , 2012, Medical physics.

[37]  Lei Zhu,et al.  Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: first patient studies. , 2012, Medical physics.

[38]  Jie Tang,et al.  Prior image constrained compressed sensing: implementation and performance evaluation. , 2011, Medical physics.

[39]  Lei Zhu,et al.  Faster STORM using compressed sensing , 2012, Nature Methods.