SQUID Systems Adapted to Record Nuclear Magnetism in Low Magnetic Fields

We modified two SQUID measurement systems, originally developed and optimized for biomagnetic applications, with the aim to employ them for observing the precession of nuclear magnetism in low fields of a microtesla or less. To this end, coil systems for the polarization and for the observation of the nuclear magnetization were added to the set-up. In addition, SQUID readout electronics had to be fast enough to allow for short dead times after switching off the polarizing field. One system was a single channel gradiometer that is routinely used for measuring the relaxing magnetism of magnetic nanoparticles. The second system was a 304 SQUID system that was designed for multichannel vector-magnetocardiography and vector-magneto-encephalography. Both systems had in common that they operated in a magnetically shielded environment provided by multi-layer mu-metal walk-in rooms. With the single channel system we determined the natural proton NMR line width of benzene in the fast motional limit to be (112 plusmn 3) mHz. The accuracy of this value was improved by excluding experimentally the presence of line broadening by the inhomogeneity of the residual environmental field in the magnetically shielded room. To this end, the transversal relaxation of hyperpolarized 129Xe gas was measured demonstrating that the spectrometer has a spectral resolution of about 6 mHz for 1H. By using a 304 SQUID vector magnetometer system the precession of 1H in multiple distilled water samples was recorded. From the spatially resolved data of the multi-SQUID system, positions and moments of the multiple samples were estimated.

[1]  Martin Burghoff,et al.  J-coupling nuclear magnetic resonance spectroscopy of liquids in nT fields. , 2006, Journal of the American Chemical Society.

[2]  Martin Burghoff,et al.  Nuclear magnetic resonance in the nanoTesla range , 2005 .

[3]  John Clarke,et al.  SQUID‐detected MRI at 132 μT with T1‐weighted contrast established at 10 μT–300 mT , 2005 .

[4]  M Burghoff,et al.  A sensor configuration for a 304 SQUID vector magnetometer. , 2004, Neurology & clinical neurophysiology : NCN.

[5]  John S George,et al.  Simultaneous magnetoencephalography and SQUID detected nuclear MR in microtesla magnetic fields , 2004, Magnetic resonance in medicine.

[6]  A. Pines,et al.  SQUID-Detected MRI at 132 Microtesla with T1 Contrast Weighted at10 Microtelsa-300 mT , 2004 .

[7]  Robert McDermott,et al.  Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields , 2002, Science.

[8]  W. Kilian Erzeugung von hyperpolarisiertem 129-Xe-Gas und Nachweis mittles in vivo NMR-Bildgebung, NMR-Spektroskopie sowie SQUID-Messtechnik , 2001 .

[9]  Robert McDermott,et al.  Low-field magnetic resonance imaging with a high-Tc dc superconducting quantum interference device , 1999 .

[10]  Dietmar Drung,et al.  A SQUID measurement system for immunoassays , 1999 .

[11]  T. Walker,et al.  Spin-exchange optical pumping of noble-gas nuclei , 1997 .

[12]  J. Hutchison,et al.  A 4.2 K receiver coil and SQUID amplifier used to improve the SNR of low-field magnetic resonance images of the human arm , 1997 .

[13]  S. N. Erné,et al.  The Berlin Magnetically Shielded Room (BMSR) Section C - Periphery , 1981 .

[14]  F. Noack,et al.  Proton spin T1 relaxation dispersion in liquid H2O by slow proton‐exchange , 1980 .

[15]  H. Carr,et al.  The Principles of Nuclear Magnetism , 1961 .