Microfluidic acoustophoretic force based low-concentration oil separation and detection from the environment.

Detecting and quantifying extremely low concentrations of oil from the environment have broad applications in oil spill monitoring in ocean and coastal areas as well as in oil leakage monitoring on land. Currently available methods for low-concentration oil detection are bulky or costly with limited sensitivities. Thus they are difficult to be used as portable and field-deployable detectors in the case of oil spills or for monitoring the long-term effects of dispersed oil on marine and coastal ecosystems. Here, we present a low-concentration oil droplet trapping and detection microfluidic system based on the acoustophoresis phenomenon where oil droplets in water having a negative acoustic contrast factor move towards acoustic pressure anti-nodes. By trapping oil droplets from water samples flowing through a microfluidic channel, even very low concentrations of oil droplets can be concentrated to a detectable level for further analyses, which is a significant improvement over currently available oil detection systems. Oil droplets in water were successfully trapped and accumulated in a circular acoustophoretic trapping chamber of the microfluidic device and detected using a custom-built compact fluorescent detector based on the natural fluorescence of the trapped crude oil droplets. After the on-line detection, crude oil droplets released from the trapping chamber were successfully separated into a collection outlet by acoustophoretic force for further off-chip analyses. The developed microfluidic system provides a new way of trapping, detecting, and separating low-concentration crude oil from environmental water samples and holds promise as a low-cost field-deployable oil detector with extremely high sensitivity. The microfluidic system and operation principle are expected to be utilized in a wide range of applications where separating, concentrating, and detecting small particles having a negative acoustic contrast factor are required.

[1]  T. Laurell,et al.  Continuous separation of lipid particles from erythrocytes by means of laminar flow and acoustic standing wave forces. , 2005, Lab on a chip.

[2]  G. Orellana,et al.  Hydrocarbon in water sensing with PTFE membranes doped with a luminescent Ru(II) poly(pyridyl) complex , 2005 .

[3]  W. Burger,et al.  A Novel Ultrasonic Resonance Field Device for the Retention of Animal Cells , 1994, Biotechnology progress.

[4]  Louis Vessot King,et al.  On the Acoustic Radiation Pressure on Spheres , 1934 .

[5]  Thomas Laurell,et al.  Trapping of microparticles in the near field of an ultrasonic transducer. , 2005, Ultrasonics.

[6]  Thomas Laurell,et al.  Non-contact acoustic cell trapping in disposable glass capillaries. , 2010, Lab on a chip.

[7]  K Yasuda,et al.  Using acoustic radiation force as a concentration method for erythrocytes. , 1997, The Journal of the Acoustical Society of America.

[8]  B. Onfelt,et al.  Flow-free transport of cells in microchannels by frequency-modulated ultrasound. , 2009, Lab on a chip.

[9]  Yong‐Joe Kim,et al.  Numerical modeling for analyzing microfluidic acoustophoretic motion of cells and particles with application to identification of vibro-acoustic properties , 2013 .

[10]  A. Abate,et al.  Surface acoustic wave (SAW) directed droplet flow in microfluidics for PDMS devices. , 2009, Lab on a chip.

[11]  H. Hertz,et al.  Wedge transducer design for two-dimensional ultrasonic manipulation in a microfluidic chip , 2008 .

[12]  Thomas Laurell,et al.  Noninvasive acoustic cell trapping in a microfluidic perfusion system for online bioassays. , 2007, Analytical chemistry.

[13]  Peng Li,et al.  Surface acoustic wave microfluidics. , 2013, Lab on a chip.

[14]  C. Peterson,et al.  Long-Term Ecosystem Response to the Exxon Valdez Oil Spill , 2003, Science.

[15]  Hyun-Woo Choi,et al.  Hebei Spirit oil spill monitored on site by fluorometric detection of residual oil in coastal waters off Taean, Korea. , 2010, Marine pollution bulletin.

[16]  J. Picou,et al.  The Exxon Valdez and BP Oil Spills , 2012 .

[17]  Thomas Laurell,et al.  Chip integrated strategies for acoustic separation and manipulation of cells and particles. , 2007, Chemical Society reviews.

[18]  R. Zika,et al.  Application of fluorescence and PARAFAC to assess vertical distribution of subsurface hydrocarbons and dispersant during the Deepwater Horizon oil spill. , 2013, Environmental science. Processes & impacts.

[19]  R. Heintz,et al.  Delayed effects on growth and marine survival of pink salmon Oncorhynchus gorbuscha after exposure to crude oil during embryonic development , 2000 .

[20]  T. Laurell,et al.  Free flow acoustophoresis: microfluidic-based mode of particle and cell separation. , 2007, Analytical chemistry.

[21]  D. Yoerger,et al.  Tracking Hydrocarbon Plume Transport and Biodegradation at Deepwater Horizon , 2010, Science.

[22]  M. Fingas,et al.  Developments in the analysis of petroleum hydrocarbons in oils, petroleum products and oil-spill-related environmental samples by gas chromatography , 1997 .

[23]  Jason Levy,et al.  Advances in Remote Sensing for Oil Spill Disaster Management: State-of-the-Art Sensors Technology for Oil Spill Surveillance , 2008, Sensors.

[24]  R. Heintz,et al.  Ascites, premature emergence, increased gonadal cell apoptosis, and cytochrome P4501A induction in pink salmon larvae continuously exposed to oil-contaminated gravel during development , 1997 .

[25]  H M Hertz,et al.  Ultrasonic-trap-enhanced selectivity in capillary electrophoresis. , 2003, Ultrasonics.

[26]  P Lambert,et al.  A literature review of portable fluorescence-based oil-in-water monitors. , 2003, Journal of hazardous materials.

[27]  Stephen E. Reichenbach,et al.  Tracking the Weathering of an Oil Spill with Comprehensive Two-Dimensional Gas Chromatography , 2006 .

[28]  R. R. Lessard,et al.  The Significance of Oil Spill Dispersants , 2000 .

[29]  R. Highsmith,et al.  Characterization of subsurface polycyclic aromatic hydrocarbons at the Deepwater Horizon site , 2010 .

[30]  D. C. Gordon,et al.  Detection of Trace Amounts of Oil in Sea Water by Fluorescence Spectroscopy , 1973 .

[31]  Thomas Laurell,et al.  Acoustic control of suspended particles in micro fluidic chips. , 2004, Lab on a chip.

[32]  K. Yosioka,et al.  Acoustic radiation pressure on a compressible sphere , 1955 .

[33]  Tony Jun Huang,et al.  An on-chip, multichannel droplet sorter using standing surface acoustic waves. , 2013, Analytical chemistry.

[34]  M Wiklund,et al.  Selective bioparticle retention and characterization in a chip‐integrated confocal ultrasonic cavity , 2009, Biotechnology and bioengineering.