Relative en- and exophthalmometry in zygomatic fractures comparing optical non-contact, non-ionizing 3D imaging to the Hertel instrument and computed tomography.
暂无分享,去创建一个
Emeka Nkenke | Gerd Häusler | Michaela Benz | Friedrich Wilhelm Neukam | Tobias Maier | Manuel Kramer | G. Häusler | E. Nkenke | F. Neukam | J. Wiltfang | L. Holbach | M. Kramer | Jörg Wiltfang | M. Benz | T. Maier | Leonard M Holbach
[1] Y. Kawano. Three dimensional analysis of the face in respect of zygomatic fractures and evaluation of the surgery with the aid of Moiré topography. , 1987, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.
[2] P. Manson,et al. Studies on Enophthalmos: II. The Measurement of Orbital Injuries and Their Treatment by Quantitative Computed Tomography , 1986, Plastic and reconstructive surgery.
[3] P. Manson,et al. Orbital volumetric analysis: clinical application in orbitozygomatic complex injuries. , 1997, The Journal of cranio-maxillofacial trauma.
[4] J. Schmitz,et al. The use of the Naugle orbitometer in maxillofacial trauma. , 1999, The Journal of cranio-maxillofacial trauma.
[5] G. Häusler,et al. Simple, robust and accurate phase-measuring triangulation , 1992 .
[6] R. Yeatts,et al. Measurement of Globe Position in Complex Orbital Fractures. I. A Modification of Hertel's Exophthalmometer, Using the External Auditory Canal as a Reference Point , 1992, Ophthalmic plastic and reconstructive surgery.
[7] M Davanger,et al. Principles and sources of error in exophthalmometry. A new exophthalmometer. , 1970, Acta ophthalmologica.
[8] Ezatollah Hazrati. Distance from symmetry: A three-dimensional evaluation of facial asymmetry. , 1996 .
[9] P. Manson,et al. Mechanisms of Global Support and Posttraumatic Enophthalmos: I. The Anatomy of the Ligament Sling and Its Relation to Intramuscular Cone Orbital Fat , 1986, Plastic and reconstructive surgery.
[10] R. Goldberg,et al. Relationship of the eye to the bony orbit, with clinical correlations. , 1999, Australian and New Zealand journal of ophthalmology.
[11] I. Kim,et al. Normal Range of Exophthalmos Values on Orbit Computerized Tomography in Koreans , 2001, Ophthalmologica.
[12] Yeatts Rp. Measurement of globe position in complex orbital fractures. II. Patient evaluation utilizing a modified exophthalmometer. , 1992 .
[13] B. Haik,et al. Exophthalmometry: A Comparative Study of the Naugle and Hertel Instruments , 1997, Ophthalmic plastic and reconstructive surgery.
[14] Taylor Cl,et al. Measurement of Globe Position in Complex Orbital Fractures. I. A Modification of Hertel's Exophthalmometer, Using the External Auditory Canal as a Reference Point , 1992 .
[15] Emeka Nkenke,et al. The Symmetry of Faces , 2002, VMV.
[16] J R Landis,et al. The reliability of Hertel exophthalmometry. Observer variation between physician and lay readers. , 1985, Ophthalmology.
[17] Emeka Nkenke,et al. Validation of In Vivo Assessment of Facial Soft‐Tissue Volume Changes and Clinical Application in Midfacial Distraction: A Technical Report , 2003, Plastic and reconstructive surgery.
[18] L. Frisén. CRITICAL ANALYSIS OF EXOPHTHALMOMETRY. AN EXPERIMENTAL EVALUATION OF CONVENTIONAL AND EXTENDED METHODS , 1967, Acta ophthalmologica.