Two‐dimensional single‐shot diffusion‐weighted stimulated EPI with reduced FOV for ultrahigh‐b radial diffusion‐weighted imaging of spinal cord

High‐resolution diffusion‐weighted imaging (DWI) of the spinal cord (SC) is problematic because of the small cross‐section of the SC and the large field inhomogeneity. Obtaining the ultrahigh‐b DWI poses a further challenge. The purpose of the study was to design and validate two‐dimensional (2D) single‐shot diffusion‐weighted stimulated echo planar imaging with reduced field of view (2D ss‐DWSTEPI‐rFOV) for ultrahigh‐b radial DWI (UHB‐rDWI) of the SC.

[1]  Gareth J. Barker,et al.  Investigating Cervical Spinal Cord Structure Using Axial Diffusion Tensor Imaging , 2002, NeuroImage.

[2]  Stephen J Blackband,et al.  Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue , 2009, Magnetic resonance in medicine.

[3]  Felix W. Wehrli,et al.  Quantifying axon diameter and intra-cellular volume fraction in excised mouse spinal cord with q-space imaging , 2010, NeuroImage.

[4]  Christian Enzinger,et al.  Method for quantitative imaging of the macromolecular 1H fraction in tissues , 2003, Magnetic resonance in medicine.

[5]  R. Mills,et al.  Self-diffusion in normal and heavy water in the range 1-45.deg. , 1973 .

[6]  E. Jeong,et al.  Using diffusion tensor imaging and immunofluorescent assay to evaluate the pathology of multiple sclerosis , 2011, Journal of magnetic resonance imaging : JMRI.

[7]  Jens Frahm,et al.  Diffusion imaging using stimulated echoes , 1991, Magnetic resonance in medicine.

[8]  M. Holz,et al.  Temperature-dependent self-diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurements , 2000 .

[9]  A. Szafer,et al.  An analytical model of restricted diffusion in bovine optic nerve , 1997, Magnetic resonance in medicine.

[10]  David C. Alsop,et al.  Diffusion restriction in the human spinal cord characterized in vivo with high b-value STEAM diffusion imaging , 2013, NeuroImage.

[11]  V. Wedeen,et al.  Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo , 2003, Magnetic resonance in medicine.

[12]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[13]  E. Kholmovski,et al.  High‐resolution DTI with 2D interleaved multislice reduced FOV single‐shot diffusion‐weighted EPI (2D ss‐rFOV‐DWEPI) , 2005, Magnetic resonance in medicine.

[14]  P. Boesiger,et al.  Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imaging , 2007, Magnetic resonance in medicine.

[15]  Derek K Jones,et al.  Applications of diffusion‐weighted and diffusion tensor MRI to white matter diseases – a review , 2002, NMR in biomedicine.

[16]  L. Hall,et al.  Optimization of diffusion measurements using Cramer‐Rao lower bound theory and its application to articular cartilage , 2003, Magnetic resonance in medicine.

[17]  K. Hasan,et al.  In vivo serial diffusion tensor imaging of experimental spinal cord injury , 2006, Journal of neuroscience research.

[18]  K Kuppusamy,et al.  High-b-value diffusion-weighted MR imaging of adult brain: image contrast and apparent diffusion coefficient map features. , 2000, AJNR. American journal of neuroradiology.

[19]  A. Uluğ,et al.  The utility of high b-value DWI in evaluation of ischemic stroke at 3T. , 2011, European journal of radiology.

[20]  G. Johnson,et al.  Diffusion tensor imaging in multiple sclerosis: assessment of regional differences in the axial plane within normal-appearing cervical spinal cord. , 2006, AJNR. American journal of neuroradiology.

[21]  F Schick,et al.  Echoplanar diffusion tensor imaging of the lower leg musculature using eddy current nulled stimulated echo preparation , 2006, Magnetic resonance in medicine.

[22]  F. Ståhlberg,et al.  On the effects of a varied diffusion time in vivo: is the diffusion in white matter restricted? , 2009, Magnetic resonance imaging.

[23]  Sharon Peled,et al.  New Perspectives on the Sources of White Matter DTI Signal , 2007, IEEE Transactions on Medical Imaging.

[24]  P. Basser,et al.  Axcaliber: A method for measuring axon diameter distribution from diffusion MRI , 2008, Magnetic resonance in medicine.

[25]  S. Ropele,et al.  Fast Bound Pool Fraction Mapping Using Stimulated Echoes , 2011, Magnetic resonance in medicine.

[26]  Thorsten Feiweier,et al.  Comparison of twice refocused spin echo versus stimulated echo diffusion tensor imaging for tracking muscle fibers , 2015, Journal of magnetic resonance imaging : JMRI.

[27]  Jin Hyung Lee,et al.  DWI of the spinal cord with reduced FOV single‐shot EPI , 2008, Magnetic resonance in medicine.

[28]  M. Holz,et al.  Biological applications of scanning tunnelling microscopy , 1993 .

[29]  KLAUS-DIETMARMERFSOLDT Jensfrahm Localized Proton Spectroscopy Using Stimulated Echoes , 2004 .

[30]  E. Jeong,et al.  Diffusion Tensor Imaging of Ex Vivo Cervical Spinal Cord Specimens: The Immediate and Long‐Term Effects of Fixation on Diffusivity , 2009, Anatomical record.

[31]  Peter C M van Zijl,et al.  High b‐value q‐space diffusion‐weighted MRI of the human cervical spinal cord in vivo: Feasibility and application to multiple sclerosis , 2008, Magnetic resonance in medicine.

[32]  J. Pekar,et al.  Echo-planar imaging of intravoxel incoherent motion. , 1990, Radiology.

[33]  Jerry L Prince,et al.  Multiparametric MRI correlates of sensorimotor function in the spinal cord in multiple sclerosis , 2013, Multiple sclerosis.

[34]  P. Fillard,et al.  MR diffusion tensor imaging and fiber tracking in spinal cord compression. , 2005, AJNR. American journal of neuroradiology.

[35]  D. Cory,et al.  Measurement of translational displacement probabilities by NMR: An indicator of compartmentation , 1990, Magnetic resonance in medicine.