Real-Time Digital Timing in Positron Emission Tomography

Positron emission tomography (PET) requires accurate timing of scintillation events to properly discriminate between coincident and noncoincident pairs. The traditional solution to timing is based on custom application specific integrated circuits (ASIC) designs, whose cost may not be justified in the design of experimental small animal PET scanners. The new generation of PET scanners introduces the idea of continuous sampling of the detected scintillation pulse, replacing event-triggered acquisition front-ends. This approach enables new options to the timing procedure based on digital processing of the sampled pulse signal. This work proposes a time stamping algorithm based on the optically matched filter and compares the potential performance benefits of this approach versus other FIR-based timing algorithms, some of which have been already implemented by different authors. Results show that the coincidence timing resolution may be as low as 1.5 ns without the need of expensive high-speed converters when the proper signal processing is applied.

[1]  J. Kostamovaara,et al.  An integrated time-to-digital converter with 30-ps single-shot precision , 2000, IEEE Journal of Solid-State Circuits.

[2]  Application of a Digital Technique for Timing of Events From Scintillation Detectors , 2006, IEEE Transactions on Nuclear Science.

[3]  Tian-Bo Deng Noniterative WLS design of allpass variable fractional-delay digital filters , 2006, IEEE Transactions on Circuits and Systems I: Regular Papers.

[4]  J. M. Rochelle,et al.  A 100-ps time-resolution CMOS time-to-digital converter for positron emission tomography imaging applications , 2004, IEEE Journal of Solid-State Circuits.

[5]  T. Bukki,et al.  Ethernet Based Distributed Data Acquisition System for a Small Animal PET , 2005, IEEE Transactions on Nuclear Science.

[6]  Soo-Chang Pei,et al.  Closed-form design of allpass fractional delay filters , 2004, 2002 IEEE International Conference on Acoustics, Speech, and Signal Processing.

[7]  Horst Halling,et al.  Coincidence detection by digital processing of free-running sampled pulses , 2002 .

[8]  G. Muehllehner,et al.  Positron emission tomography , 2006, Physics in medicine and biology.

[9]  H. Vincent Poor,et al.  Robust Matched Filters for Optical Receivers , 1987, IEEE Trans. Commun..

[10]  P. Relvas,et al.  Performance Simulation Studies of the Clear-PEM DAQ/Trigger System , 2005, IEEE Transactions on Nuclear Science.

[11]  Soo-Chang Pei,et al.  Closed-form design of all-pass fractional delay filters , 2004, IEEE Signal Processing Letters.

[12]  G. Brandenburg,et al.  Timemark correction for the ClearPET/spl trade/ scanners , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[13]  Jurgen Seidel,et al.  Resolution uniformity and sensitivity of the NIH ATLAS small animal PET scanner: comparison to simulated LSO scanners without depth-of-interaction capability , 2001 .

[14]  R. Fontaine,et al.  Time Discrimination Techniques Using Artificial Neural Networks for Positron Emission Tomography , 2004, IEEE Transactions on Nuclear Science.

[15]  M. Komodromos,et al.  Design of FIR Hilbert transformers and differentiators in the complex domain , 1998 .

[16]  Matti Karjalainen,et al.  Implementation of fractional delay waveguide models using allpass filters , 1995, 1995 International Conference on Acoustics, Speech, and Signal Processing.

[17]  R. Fontaine,et al.  Real time digital signal processing implementation for an APD-based PET scanner with phoswich detectors , 2005, IEEE Transactions on Nuclear Science.

[18]  Jurgen Seidel,et al.  Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  Alfred O. Hero Timing estimation for a filtered Poisson process in Gaussian noise , 1991, IEEE Trans. Inf. Theory.

[20]  Christian Bohm,et al.  Sampling Pulses for Optimal Timing , 2007, IEEE Transactions on Nuclear Science.

[21]  P. Dudek,et al.  A high-resolution CMOS time-to-digital converter utilizing a Vernier delay line , 2000, IEEE Journal of Solid-State Circuits.

[22]  Christopher J. Thompson,et al.  A method for determination of the timing stability of PET scanners , 2005, IEEE Transactions on Medical Imaging.