A Methodology for Validating Artifact Removal Techniques for Physiological Signals

Artifact removal from physiological signals is an essential component of the biosignal processing pipeline. The need for powerful and robust methods for this process has become particularly acute as healthcare technology deployment undergoes transition from the current hospital-centric setting toward a wearable and ubiquitous monitoring environment. Currently, determining the relative efficacy and performance of the multiple artifact removal techniques available on real world data can be problematic, due to incomplete information on the uncorrupted desired signal. The majority of techniques are presently evaluated using simulated data, and therefore, the quality of the conclusions is contingent on the fidelity of the model used. Consequently, in the biomedical signal processing community, there is considerable focus on the generation and validation of appropriate signal models for use in artifact suppression. Most approaches rely on mathematical models which capture suitable approximations to the signal dynamics or underlying physiology and, therefore, introduce some uncertainty to subsequent predictions of algorithm performance. This paper describes a more empirical approach to the modeling of the desired signal that we demonstrate for functional brain monitoring tasks which allows for the procurement of a “ground truth” signal which is highly correlated to a true desired signal that has been contaminated with artifacts. The availability of this “ground truth,” together with the corrupted signal, can then aid in determining the efficacy of selected artifact removal techniques. A number of commonly implemented artifact removal techniques were evaluated using the described methodology to validate the proposed novel test platform.

[1]  Tomás Ward,et al.  Artifact Removal in Physiological Signals—Practices and Possibilities , 2012, IEEE Transactions on Information Technology in Biomedicine.

[2]  Daniel P. Ferris,et al.  Removal of movement artifact from high-density EEG recorded during walking and running. , 2010, Journal of neurophysiology.

[3]  Soo-Young Lee Blind Source Separation and Independent Component Analysis: A Review , 2005 .

[4]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[5]  Dimitris G. Manolakis,et al.  Statistical and Adaptive Signal Processing , 2000 .

[6]  H. K. Verma,et al.  RETRACTED: Artifacts and noise removal in electrocardiograms using independent component analysis , 2008 .

[7]  H. K. Verma,et al.  Artifacts and noise removal in electrocardiograms using independent component analysis. , 2008, International journal of cardiology.

[8]  Hasan Ayaz,et al.  A methodology for validating artifact removal techniques for fNIRS , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[9]  N. Huang,et al.  The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis , 1998, Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[10]  S. Bunce,et al.  Functional near-infrared spectroscopy , 2006, IEEE Engineering in Medicine and Biology Magazine.

[11]  Christian Jutten,et al.  A Nonlinear Bayesian Filtering Framework for ECG Denoising , 2007, IEEE Transactions on Biomedical Engineering.

[12]  Sabine Van Huffel,et al.  Source Separation From Single-Channel Recordings by Combining Empirical-Mode Decomposition and Independent Component Analysis , 2010, IEEE Transactions on Biomedical Engineering.

[13]  A. J. Bell,et al.  INDEPENDENT COMPONENT ANALYSIS OF BIOMEDICAL SIGNALS , 2000 .

[14]  Robert Oostenveld,et al.  The five percent electrode system for high-resolution EEG and ERP measurements , 2001, Clinical Neurophysiology.

[15]  Hung T. Nguyen,et al.  Real-time microcontroller based brain computer interface for mental task classifications using wireless EEG signals from two channels , 2012, BioMed 2012.

[16]  Kevin T Sweeney,et al.  Intelligent artifact classification for ambulatory physiological signals , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[17]  Joydeep Bhattacharya,et al.  Correction of blink artifacts using independent component analysis and empirical mode decomposition. , 2010, Psychophysiology.

[18]  Meltem Izzetoglu,et al.  Motion artifact cancellation in NIR spectroscopy using discrete Kalman filtering , 2010, Biomedical engineering online.

[19]  J. L. Roux An Introduction to the Kalman Filter , 2003 .

[20]  Norden E. Huang,et al.  Ensemble Empirical Mode Decomposition: a Noise-Assisted Data Analysis Method , 2009, Adv. Data Sci. Adapt. Anal..

[21]  S. Haykin,et al.  Adaptive Filter Theory , 1986 .

[22]  Qiang Wang,et al.  Accent extraction of emotional speech based on modified ensemble empirical mode decomposition , 2010, 2010 IEEE Instrumentation & Measurement Technology Conference Proceedings.

[23]  Hasan Ayaz,et al.  Using MazeSuite and Functional Near Infrared Spectroscopy to Study Learning in Spatial Navigation , 2011, Journal of visualized experiments : JoVE.