Performance of a muscle-like “leaky” pneumatic actuator powered by modulated air pulses

There is current interest in the development of legged robotic devices inspired by biological walking systems. We have developed an actuator for this type of device that closely emulates the performance of muscle. The actuator is a “leaky” single-effect air cylinder controlled through a 3-way valve that either permits charging the cylinder with compressed air or opens it to the atmosphere. To emulate muscular activation with trains of identical nerve impulses that vary in frequency, we controlled the pressure in the cylinder through pulse frequency modulation. To allow a comparison between our cylinder and muscle, we evaluated the open loop performance of the cylinder and valve system in isometric (no motion) and linear isotonic (constant load) conditions. We demonstrate that this mode of activation of the cylinder makes its behavior quite close to that of muscle. Furthermore, our cylinder/valve system generated twice the tension developed by muscle of the same cross-sectional area, with half its power-to-weight ratio. © 1996 John Wiley & Sons, Inc.

[1]  J. Eccles,et al.  The isometric responses of mammalian muscles , 1930, The Journal of physiology.

[2]  B. R. Jewell,et al.  An analysis of the mechanical components in frog's striated muscle , 1958, The Journal of physiology.

[3]  F E Zajac,et al.  Catch Property in Single Mammalian Motor Units , 1970, Science.

[4]  H. Scharstein Input-output relationship of the Leaky-Integrator Neuron Model , 1979, Journal of mathematical biology.

[5]  Elicitation and abrupt termination of behaviorally significant catchlike tension in a primitive insect. , 1983, Journal of neurobiology.

[6]  Gerry B. Andeen Robot design handbook , 1988 .

[7]  Rodney A. Brooks,et al.  A Robot that Walks; Emergent Behaviors from a Carefully Evolved Network , 1989, Neural Computation.

[8]  B. Hannaford,et al.  Actuator Properties and Movement Control: Biological and Technological Models , 1990 .

[9]  Tateo Shimozawa Sensory capacity and behaviour of insects , 1990, Adv. Robotics.

[10]  Rajendra Singh,et al.  A Linear Time Varying Model for On-Off Valve Controlled Pneumatic Actuators , 1990 .

[11]  I. Hunter,et al.  A comparison of muscle with artificial actuators , 1992, Technical Digest IEEE Solid-State Sensor and Actuator Workshop.

[12]  A. Jutard,et al.  Models of a Pneumatic PWM Solenoid Valve for Engineering Applications , 1992 .

[13]  William Whittaker,et al.  Exploring Mount Erebus by walking robot , 1993, Robotics Auton. Syst..

[14]  Friedrich Pfeiffer,et al.  Leg Design Based on Biological Principles , 1993 .

[15]  J. Wessberg,et al.  Organization of motor output in slow finger movements in man. , 1993, The Journal of physiology.

[16]  Stephen D. Prior,et al.  Actuators for rehabilitation robots , 1993 .

[17]  Dick Price Climbing the walls , 1995, IEEE Expert.

[18]  Mark E. Nelson,et al.  Sense Organs of Insect Legs and the Selection of Sensors for Agile Walking Robots , 1996, Int. J. Robotics Res..