High-resolution image reconstruction for PET using estimated detector response functions

The accuracy of the system model in an iterative reconstruction algorithm greatly affects the quality of reconstructed PET images. For efficient computation in reconstruction, the system model in PET can be factored into a product of geometric projection matrix and detector blurring matrix, where the former is often computed based on analytical calculation, and the latter is estimated using Monte Carlo simulations. In this work, we propose a method to estimate the 2D detector blurring matrix from experimental measurements. Point source data were acquired with high-count statistics in the microPET II scanner using a computer-controlled 2-D motion stage. A monotonically convergent iterative algorithm has been derived to estimate the detector blurring matrix from the point source measurements. The algorithm takes advantage of the rotational symmetry of the PET scanner with the modeling of the detector block structure. Since the resulting blurring matrix stems from actual measurements, it can take into account the physical effects in the photon detection process that are difficult or impossible to model in a Monte Carlo simulation. Reconstructed images of a line source phantom show improved resolution with the new detector blurring matrix compared to the original one from the Monte Carlo simulation. This method can be applied to other small-animal and clinical scanners.

[1]  R. Leahy,et al.  Accurate geometric and physical response modelling for statistical image reconstruction in high resolution PET , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[2]  Jinyi Qi Maximum-Likelihood Estimation of Detector Response for PET Image Reconstruction , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  R. Lecomte,et al.  Detector response models for statistical iterative image reconstruction in high resolution PET , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[4]  C.A. Bouman,et al.  Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner , 2003, IEEE Transactions on Medical Imaging.

[5]  R. Leahy,et al.  High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner. , 1998, Physics in medicine and biology.

[6]  S. Cherry,et al.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging. , 2003, Physics in medicine and biology.

[7]  Thomas K. Lewellen,et al.  Modeling and incorporation of system response functions in 3-D whole body PET , 2006, IEEE Transactions on Medical Imaging.

[8]  Vladimir Y. Panin,et al.  Fully 3-D PET reconstruction with system matrix derived from point source measurements , 2006, IEEE Transactions on Medical Imaging.