A polymer-based bidirectional micropump driven by a PZT bimorph

This paper presents a polymer-based micropump for liquid control or drug delivery. The dimension of the pump was 20 × 24 × 3 mm3. A pair of O-ring SU-8 passive valves was fabricated by lift-off technique to control the fluid movement. Micropumps with dimple, bridge, and cantilever valves were studied. The PZT bimorph acted on the polymer membrane to periodically drive fluid. The maximum flow rate was 16.4 ml/min, and the back pressure was 1,525 mmH2O at 150 V (Vp-p). In frequency sweeping experiments, two flow rate peaks and back pressure peaks were analyzed. Bidirectional flow rate was achieved by changing the valve seat from a one-size hole to a step hole. The maximum backward flow rate was 5.1 ml/min, and the driving frequency was about 355 Hz higher than the forward flow rate driving frequency.

[1]  W. Ehrfeld,et al.  A self-filling low-cost membrane micropump , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[2]  Thayne L Edwards,et al.  Multi-layer plastic/glass microfluidic systems containing electrical and mechanical functionality. , 2003, Lab on a chip.

[3]  Bruce C. Towe,et al.  A thermopneumatic dispensing micropump , 2004 .

[4]  Hsien-Tsung Chang,et al.  A MEMS-based valveless impedance pump utilizing electromagnetic actuation , 2008 .

[5]  Jae Sung Yoon,et al.  A valveless micropump for bidirectional applications , 2007 .

[6]  P. Bergveld,et al.  A plastic micropump constructed with conventional techniques and materials , 1999 .

[7]  Neil M. White,et al.  A novel micropump design with thick-film piezoelectric actuation , 1997 .

[8]  Eun Kyu Lee,et al.  Continuous dynamic flow micropumps for microfluid manipulation , 2007 .

[9]  Peter Woias,et al.  A novel artificial sphincter prosthesis driven by a four-membrane silicon micropump ☆ , 2007 .

[10]  Jong-Hyun Lee,et al.  A novel micropump with fixed-geometry valves and low leakage flow , 2007 .

[11]  Martin A. M. Gijs,et al.  Miniaturized PMMA ball-valve micropump with cylindrical electromagnetic actuator , 2008 .

[12]  J. Hausselt,et al.  Manufacturing of isolated ceramic microstructures , 2002 .

[13]  Ansgar Wego,et al.  A self-filling micropump based on PCB technology , 2001 .

[14]  M. Richter,et al.  A bidirectional silicon micropump , 1995 .

[15]  Asim Nisar,et al.  MEMS-based micropumps in drug delivery and biomedical applications , 2008 .

[16]  Nam-Trung Nguyen,et al.  A polymeric piezoelectric micropump based on lamination technology , 2004 .

[17]  Kwang J. Kim,et al.  Design of IPMC actuator-driven valve-less micropump and its flow rate estimation at low Reynolds numbers , 2006 .