An over view of damping methods for three-phase PWM rectifier

In this paper, an over view of damping method for three-phase voltage-source PWM rectifier with LCL filter is given. The traditional rectifier connected to supply network with an L filter. Increasing the L value can attenuate the ripple current around switch frequency which fulfills standards but it will decrease the response speed and stability of the system. An LCL filter is more effective and reduce harmonic distortion at lower switch frequency than an L filter. However an LCL filter will bring stability problem. One solution is to use a damping resistor which is in series or parallel with the filter capacitor and this is called "passive damping". This method will increase the losses and decrease the efficiency of the system. Other solution is to modify control algorithm to stabilize the system which is called "active damping (AD)". This method avoid lose problem through adding complexity of control strategy. This paper analyze damping principle of each method include passive damping and active damping, show the advantages and disadvantages of these methods. In this paper, the ripple current attenuation function of passive damping is given to analyze the filter effort for the first time. At the end of this paper, a prospect on this subject is given.

[1]  F.A. Magueed,et al.  Control of VSC connected to the grid through LCL-filter to achieve balanced currents , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[2]  E.J. Bueno,et al.  Current control of voltage source converters connected to the grid through an LCL-filter , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[3]  Dianguo Xu,et al.  A Novel Design Method of LCL Type Utility Interface for Three-Phase Voltage Source Rectifier , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[4]  P.A. Dahono A control method for DC-DC converter that has an LCL output filter based on new virtual capacitor and resistor concepts , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[5]  M.P. Kazmierkowski,et al.  Sensorless operation of active damping methods for three-phase PWM converters , 2005, Proceedings of the IEEE International Symposium on Industrial Electronics, 2005. ISIE 2005..

[6]  M. Liserre,et al.  Stability improvements of an LCL-filter based three-phase active rectifier , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[7]  M. Liserre,et al.  A stable three-phase LCL-filter based active rectifier without damping , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[8]  Pekik Argo Dahono A control method to damp oscillation in the input LC filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[9]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[10]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter , 1997 .

[11]  Dehong Xu,et al.  An improved control strategy for grid-connected voltage source inverters with a LCL filter , 2006, Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06..

[12]  J.W. Kolar,et al.  A modified direct power control strategy allowing the connection of three-phase inverter to the grid through LCL filters , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[13]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[14]  M. Liserre,et al.  Grid Impedance Estimation via Excitation of $LCL$ -Filter Resonance , 2007, IEEE Transactions on Industry Applications.

[15]  M. Liserre,et al.  Genetic algorithm based design of the active damping for a LCL-filter three-phase active rectifier , 2004, Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03..

[16]  S. Bernet,et al.  Simple sensorless active damping solution for three-phase PWM rectifier with LCL filter , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[17]  J. Svensson,et al.  Control of a voltage-source converter connected to the grid through an LCL-filter-application to active filtering , 1998, PESC 98 Record. 29th Annual IEEE Power Electronics Specialists Conference (Cat. No.98CH36196).

[18]  S. Bernet,et al.  New simple active damping of resonance in three-phase PWM converter with LCL filter , 2005, 2005 IEEE International Conference on Industrial Technology.