Induction generators phasor simulation in dq coordinates with unbalanced operating conditions

This paper discusses the modeling for simulation based studies of induction generators in the context of power system electromechanical transient analysis and under voltage/current imbalance. Difficulties arise since voltage/current imbalance implies the presence of sinusoidal signal in the synchronous reference frame, which prevents dq variables to be directly associated to phasors and, consequently, to conduct phasor based simulations. An average phasor model is developed for the induction generator which decomposes the electrical part of the model into positive and negative sequence dq reference frames and neglect torque oscillations induced by current imbalance. The average model is developed in Matlab/Simulink applied to a simplified distributed generation system and its performance is evaluated by comparing to continuous (sinusoidal) simulations developed with Alternative Transients Program (ATP).

[1]  祐子 植田,et al.  Global Wind Energy Outlook 2012 概説 , 2013 .

[2]  Nicholas Jenkins,et al.  Direct solution method for initialising doubly-fed induction wind turbines in power system dynamic models , 2003 .

[3]  Alessandro Ferrero,et al.  A new approach to the definition of power components in three-phase systems under nonsinusoidal conditions , 1991 .

[4]  Alessandro Ferrero,et al.  Current decomposition in asymmetrical, unbalanced three-phase systems under nonsinusoidal conditions , 1994 .

[5]  Eduard Muljadi,et al.  Understanding the unbalanced-voltage problem in wind turbine generation , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[6]  Lie Xu,et al.  Coordinated Control of DFIG and FSIG-Based Wind Farms Under Unbalanced Grid Conditions , 2010, IEEE Transactions on Power Delivery.

[7]  Walmir Freitas,et al.  Three-phase doubly fed induction generators: an overview , 2010 .

[8]  Lie Xu,et al.  Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions , 2007, IEEE Transactions on Power Systems.

[9]  V. Akhmatov Analysis of Dynamic Behaviour of Electric Power Systems with Large Amount of Wind Power , 2003 .

[10]  Janaka Ekanayake,et al.  Dynamic modeling of doubly fed induction generator wind turbines , 2003 .

[11]  Thomas Ackermann,et al.  Wind Power in Power Systems , 2005 .

[12]  J.V. Milanovic,et al.  Assessing Transient Response of DFIG-Based Wind Plants—The Influence of Model Simplifications and Parameters , 2008, IEEE Transactions on Power Systems.

[13]  Rodrigo A. Ramos,et al.  On electrical power evaluation in dq coordinates under sinusoidal unbalanced conditions , 2014 .