Joint Design of RF and gradient waveforms via auto-differentiation for 3D tailored excitation in MRI

This paper proposes a new method for joint design of radiofrequency (RF) and gradient waveforms in Magnetic Resonance Imaging (MRI), and applies it to the design of 3D spatially tailored saturation and inversion pulses. The joint design of both waveforms is characterized by the ODE Bloch equations, to which there is no known direct solution. Existing approaches therefore typically rely on simplified problem formulations based on, e.g., the small-tip approximation or constraining the gradient waveforms to particular shapes, and often apply only to specific objective functions for a narrow set of design goals (e.g., ignoring hardware constraints). This paper develops and exploits an auto-differentiable Bloch simulator to directly obtain Jacobians of the (Bloch-simulated) excitation pattern with respect to RF and gradient waveforms. This approach is compatible with arbitrary sub-differentiable loss functions, and optimizes the RF and gradients directly without restricting the waveform shapes. To reduce computation, we derive and implement explicit Bloch simulator Jacobians (approximately halving computation time and memory usage). To enforce hardware limits (peak RF, gradient, and slew rate), we use a change of variables that makes the 3D pulse design problem effectively unconstrained; we then optimize the resulting problem directly using the proposed auto-differentiation framework. We demonstrate our approach with two kinds of 3D excitation pulses that cannot be easily designed with conventional approaches: Outer-volume saturation (90{\deg} flip angle), and inner-volume inversion.

[1]  Lawrence L Wald,et al.  Fast three‐dimensional inner volume excitations using parallel transmission and optimized k‐space trajectories , 2016, Magnetic Resonance in Medicine.

[2]  Feng Jia,et al.  Pulseq: A rapid and hardware‐independent pulse sequence prototyping framework , 2017, Magnetic resonance in medicine.

[3]  Hao Sun,et al.  Topics in Steady-state MRI Sequences and RF Pulse Optimization. , 2015 .

[4]  William A Grissom,et al.  Small‐tip‐angle spokes pulse design using interleaved greedy and local optimization methods , 2012, Magnetic resonance in medicine.

[5]  Kawin Setsompop,et al.  Advancing RF pulse design using an open‐competition format: Report from the 2015 ISMRM challenge , 2017, Magnetic resonance in medicine.

[6]  Luca Antiga,et al.  Automatic differentiation in PyTorch , 2017 .

[7]  B. Hargreaves,et al.  Variable‐rate selective excitation for rapid MRI sequences , 2004, Magnetic resonance in medicine.

[8]  A. Macovski,et al.  Variable-rate selective excitation , 1988 .

[9]  Douglas C Noll,et al.  Joint design of trajectory and RF pulses for parallel excitation , 2007, Magnetic resonance in medicine.

[10]  Vivek K. Goyal,et al.  Sparsity-Enforced Slice-Selective MRI RF Excitation Pulse Design , 2008, IEEE Transactions on Medical Imaging.

[11]  Jeffrey A. Fessler,et al.  Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI , 2016, IEEE Transactions on Medical Imaging.

[12]  A. Macovski,et al.  Optimal Control Solutions to the Magnetic Resonance Selective Excitation Problem , 1986, IEEE Transactions on Medical Imaging.

[13]  Alexander Hammers,et al.  Tailored excitation in 3D with spiral nonselective (SPINS) RF pulses , 2012, Magnetic resonance in medicine.

[14]  Douglas C Noll,et al.  Fast joint design method for parallel excitation radiofrequency pulse and gradient waveforms considering off‐resonance , 2012, Magnetic resonance in medicine.

[15]  Fern S. Sisser,et al.  Elimination of bounds in optimization problems by transforming variables , 1981, Math. Program..

[16]  Jon-Fredrik Nielsen,et al.  TOPPE: A framework for rapid prototyping of MR pulse sequences , 2018, Magnetic resonance in medicine.

[17]  Andreas Griewank,et al.  Evaluating derivatives - principles and techniques of algorithmic differentiation, Second Edition , 2000, Frontiers in applied mathematics.

[18]  Advanced Three-Dimensional Tailored RF Pulse Design in Volume Selective Parallel Excitation , 2012, IEEE Transactions on Medical Imaging.

[19]  E. Adalsteinsson,et al.  Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels , 2008, Magnetic resonance in medicine.

[20]  Christian Clason,et al.  NONSMOOTH ANALYSIS AND OPTIMIZATION , 2017, 1708.04180.

[21]  Jeffrey A. Fessler,et al.  Fast Large-Tip-Angle Multidimensional and Parallel RF Pulse Design in MRI , 2009, IEEE Transactions on Medical Imaging.

[22]  D Le Bihan,et al.  kT‐points: Short three‐dimensional tailored RF pulses for flip‐angle homogenization over an extended volume , 2012, Magnetic resonance in medicine.

[23]  Johnpauly A k-Space Analysis of Small-Tip-Angle Excitation , 2012 .

[24]  Frank J Rybicki,et al.  Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses. , 2005, Medical physics.

[25]  Zhi-Pei Liang,et al.  Joint design of spoke trajectories and RF pulses for parallel excitation , 2011, Magnetic resonance in medicine.

[26]  Douglas C Noll,et al.  Iterative RF pulse design for multidimensional, small‐tip‐angle selective excitation , 2005, Magnetic resonance in medicine.

[27]  Matthew O'Donnell,et al.  Optimization of two-dimensional spatially selective NMR pulses by simulated annealing , 1988 .

[28]  P. Boesiger,et al.  Reduced field‐of‐view MRI using outer volume suppression for spinal cord diffusion imaging , 2007, Magnetic resonance in medicine.