Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part II. Task-based parameter optimization).

PURPOSE Different low-signal correction (LSC) methods have been shown to efficiently reduce noise streaks and noise level in CT to provide acceptable images at low-radiation dose levels. These methods usually result in CT images with highly shift-variant and anisotropic spatial resolution and noise, which makes the parameter optimization process highly nontrivial. The purpose of this work was to develop a local task-based parameter optimization framework for LSC methods. METHODS Two well-known LSC methods, the adaptive trimmed mean (ATM) filter and the anisotropic diffusion (AD) filter, were used as examples to demonstrate how to use the task-based framework to optimize filter parameter selection. Two parameters, denoted by the set P, for each LSC method were included in the optimization problem. For the ATM filter, these parameters are the low- and high-signal threshold levels pl and ph ; for the AD filter, the parameters are the exponents δ and γ in the brightness gradient function. The detectability index d' under the non-prewhitening (NPW) mathematical observer model was selected as the metric for parameter optimization. The optimization problem was formulated as an unconstrained optimization problem that consisted of maximizing an objective function d'(P), where i and j correspond to the i-th imaging task and j-th spatial location, respectively. Since there is no explicit mathematical function to describe the dependence of d' on the set of parameters P for each LSC method, the optimization problem was solved via an experimentally measured d' map over a densely sampled parameter space. In this work, three high-contrast-high-frequency discrimination imaging tasks were defined to explore the parameter space of each of the LSC methods: a vertical bar pattern (task I), a horizontal bar pattern (task II), and a multidirectional feature (task III). Two spatial locations were considered for the analysis, a posterior region-of-interest (ROI) located within the noise streaks region and an anterior ROI, located further from the noise streaks region. Optimal results derived from the task-based detectability index metric were compared to other operating points in the parameter space with different noise and spatial resolution trade-offs. RESULTS The optimal operating points determined through the d' metric depended on the interplay between the major spatial frequency components of each imaging task and the highly shift-variant and anisotropic noise and spatial resolution properties associated with each operating point in the LSC parameter space. This interplay influenced imaging performance the most when the major spatial frequency component of a given imaging task coincided with the direction of spatial resolution loss or with the dominant noise spatial frequency component; this was the case of imaging task II. The performance of imaging tasks I and III was influenced by this interplay in a smaller scale than imaging task II, since the major frequency component of task I was perpendicular to imaging task II, and because imaging task III did not have strong directional dependence. For both LSC methods, there was a strong dependence of the overall d' magnitude and shape of the contours on the spatial location within the phantom, particularly for imaging tasks II and III. The d' value obtained at the optimal operating point for each spatial location and imaging task was similar when comparing the LSC methods studied in this work. CONCLUSIONS A local task-based detectability framework to optimize the selection of parameters for LSC methods was developed. The framework takes into account the potential shift-variant and anisotropic spatial resolution and noise properties to maximize the imaging performance of the CT system. Optimal parameters for a given LSC method depend strongly on the spatial location within the image object.

[1]  H. Barrett,et al.  Effect of noise correlation on detectability of disk signals in medical imaging. , 1985, Journal of the Optical Society of America. A, Optics and image science.

[2]  Katsuyuki Taguchi,et al.  Characterization of a novel photon counting detector for clinical CT: count rate, energy resolution, and noise performance , 2009, Medical Imaging.

[3]  Grace J Gang,et al.  Task-driven optimization of CT tube current modulation and regularization in model-based iterative reconstruction , 2017, Physics in medicine and biology.

[4]  C. McCollough,et al.  Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging. , 2015, Medical physics.

[5]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[6]  P. Prescott Selection of Trimming Proportions for Robust Adaptive Trimmed Means , 1978 .

[7]  J Y Vaishnav,et al.  Objective assessment of image quality and dose reduction in CT iterative reconstruction. , 2014, Medical physics.

[8]  Max A. Viergever,et al.  Efficient and reliable schemes for nonlinear diffusion filtering , 1998, IEEE Trans. Image Process..

[9]  Alfredo Restrepo,et al.  Adaptive trimmed mean filters for image restoration , 1988, IEEE Trans. Acoust. Speech Signal Process..

[10]  X Duan,et al.  Initial results from a prototype whole-body photon-counting computed tomography system , 2015, Medical Imaging.

[11]  Rui J. P. de Figueiredo,et al.  Adaptive alpha-trimmed mean filters under deviations from assumed noise model , 2004, IEEE Trans. Image Process..

[12]  Ke Li,et al.  Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part I: Assessment of spatial resolution and noise performance). , 2018, Medical physics.

[13]  W. Kalender,et al.  Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT. , 2001, Medical physics.

[14]  Jeffrey H Siewerdsen,et al.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images. , 2008, Medical physics.

[15]  Kyle J. Myers,et al.  Model observers for assessment of image quality , 1993 .

[16]  Grace J Gang,et al.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation. , 2014, Medical physics.

[17]  Grace J Gang,et al.  Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance. , 2011, Medical physics.

[18]  J. Hsieh Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. , 1998, Medical physics.

[19]  E Grabbe,et al.  [An anatomically adapted variation of the tube current in CT. Studies on radiation dosage reduction and image quality]. , 1995, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[20]  Shuai Leng,et al.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain. , 2013, Medical physics.

[21]  Ke Li,et al.  Noise performance studies of model-based iterative reconstruction (MBIR) as a function of kV, mA and exposure level: Impact on radiation dose reduction and image quality , 2015, Medical Imaging.

[22]  Guang-Hong Chen,et al.  Statistical model based iterative reconstruction in clinical CT systems. Part III. Task-based kV/mAs optimization for radiation dose reduction. , 2015, Medical physics.

[23]  Armando Manduca,et al.  Adaptive modulation of bilateral filtering based on a practical noise model for streaking and noise reduction in multi-slice CT , 2010, Medical Imaging.

[24]  Ke Li,et al.  Modified ideal observer model (MIOM) for high‐contrast and high‐spatial resolution CT imaging tasks , 2017, Medical physics.

[25]  D. Jaffray,et al.  The influence of bowtie filtration on cone-beam CT image quality , 2008 .

[26]  Edgar Kraft,et al.  A research prototype system for quantum-counting clinical CT , 2010, Medical Imaging.

[27]  Kenneth E. Weaver,et al.  An Assortment Of Image Quality Indexes For Radiographic Film-Screen Combinations ---Can They Be Resolved? , 1972, Other Conferences.

[28]  David Jaffray,et al.  Fluence field optimization for noise and dose objectives in CT. , 2011, Medical physics.

[29]  Hongbing Lu,et al.  Nonlinear sinogram smoothing for low-dose X-ray CT , 2004 .

[30]  C. Mistretta,et al.  Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results. , 2013, Medical physics.

[31]  Cynthia M. McCollough,et al.  Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT. , 2009, Medical physics.

[32]  Werner Jaschke,et al.  Das Smart-Scan-Verfahren der Spiral-Computertomographie : Eine neue Methode der Dosisreduktion , 1996 .

[33]  Timothy P. Szczykutowicz,et al.  Design of a digital beam attenuation system for computed tomography: part I. System design and simulation framework. , 2013, Medical physics.

[34]  Guang-Hong Chen,et al.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction. , 2013, Medical physics.

[35]  Guang-Hong Chen,et al.  Hi-Res scan mode in clinical MDCT systems: Experimental assessment of spatial resolution performance. , 2016, Medical physics.

[36]  J Yorkston,et al.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging. , 2011, Medical physics.

[37]  James H Thrall,et al.  Multi-detector row CT: radiation dose characteristics. , 2003, Radiology.

[38]  Norbert J Pelc,et al.  The feasibility of a piecewise-linear dynamic bowtie filter. , 2013, Medical physics.

[39]  Jing Wang,et al.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography , 2006, IEEE Transactions on Medical Imaging.

[40]  Patrick J. La Rivière,et al.  Reduction of noise-induced streak artifacts in X-ray computed tomography through spline-based penalized-likelihood sinogram smoothing , 2005, IEEE Transactions on Medical Imaging.

[41]  Ehsan Samei,et al.  Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology. , 2014, Medical physics.

[42]  Guang-Hong Chen,et al.  Low signal correction scheme for low dose CBCT: the good, the bad, and the ugly , 2017, Medical Imaging.

[43]  M. Kalra,et al.  Techniques and applications of automatic tube current modulation for CT. , 2004, Radiology.