Poly (3,4-Ethylenedioxythiophene) for Chronic Neural Stimulation

Chronic neural stimulation using microelectrode arrays requires highly stable and biocompatible electrode materials with high charge injection capability. Conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT) was electrochemically deposited on thin film Pt electrodes of stimulation electrode arrays to evaluate its properties for chronic stimulation. The coated electrodes demonstrated much lower impedance than thin film Pt due to the high surface area and high ion conductivity across the film. The PEDOT film also presents intrinsic redox activity which contributes to the low impedance as well as a much higher charge storage capacity. The charge injection limit of PEDOT electrode was found to be 2.3 mC/cm2 , comparable to IrOx and much higher than thin film Pt. Under biphasic stimulation, the coated electrodes exhibited lower voltage and linear voltage excursion. Well-coated PEDOT electrodes were stable under chronic stimulation conditions, suggesting that PEDOT is a promising electrode material to be further developed for chronic neural stimulation applications.

[1]  Tipu Z. Aziz,et al.  Deep brain stimulation for pain relief: A meta-analysis , 2005, Journal of Clinical Neuroscience.

[2]  J. Volkmann DEEP BRAIN STIMULATION II Deep Brain Stimulation for the Treatment of Parkinson’s Disease , 2004 .

[3]  J. Reynolds,et al.  In situ conductivity studies of poly(3,4-ethylenedioxythiophene) , 1998 .

[4]  S.F. Cogan,et al.  Electrodeposited iridium oxide for neural stimulation and recording electrodes , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[5]  David C. Martin,et al.  Effect of Immobilized Nerve Growth Factor on Conductive Polymers: Electrical Properties and Cellular Response , 2007 .

[6]  J. Hetke,et al.  Surface modification of neural recording electrodes with conducting polymer/biomolecule blends. , 2001, Journal of biomedical materials research.

[7]  Manjunatha Mahadevappa,et al.  Electrical Stimulus Parameters for Visual Perception in Blind Humans with Retinal Prosthetic Implants , 2003 .

[8]  David C. Martin,et al.  Conducting polymers grown in hydrogel scaffolds coated on neural prosthetic devices. , 2004, Journal of biomedical materials research. Part A.

[9]  David C. Martin,et al.  In vivo studies of polypyrrole/peptide coated neural probes. , 2003, Biomaterials.

[10]  F. Hambrecht,et al.  CRITERIA FOR SELECTING ELECTRODES FOR ELECTRICAL STIMULATION: THEORETICAL AND PRACTICAL CONSIDERATIONS , 1983, Annals of the New York Academy of Sciences.

[11]  James D. Weiland,et al.  Chronic neural stimulation with thin-film, iridium oxide electrodes , 2000, IEEE Trans. Biomed. Eng..

[12]  Dong Hwan Kim,et al.  Ordered surfactant-templated poly(3,4-ethylenedioxythiophene) (PEDOT) conducting polymer on microfabricated neural probes. , 2005, Acta biomaterialia.

[13]  Hitoshi Yamato,et al.  Stability of polypyrrole and poly(3,4-ethylenedioxythiophene) for biosensor application , 1995 .

[14]  J. Weiland,et al.  Pattern electrical stimulation of the human retina , 1999, Vision Research.

[15]  John R. Reynolds,et al.  Electrochemical polymerization of poly(hydroxymethylated-3,4-ethylenedioxythiophene) (PEDOT-MeOH) on multichannel neural probes , 2004 .

[16]  J. C. Middlebrooks,et al.  Cochlear implants: the view from the brain , 2005, Current Opinion in Neurobiology.

[17]  David C. Martin,et al.  Microporous conducting polymers on neural microelectrode arrays: II. Physical characterization , 2004 .

[18]  E. Zrenner,et al.  Long-term survival of retinal cell cultures on retinal implant materials , 1999, Vision Research.

[19]  Andrew B Schwartz,et al.  Cortical neural prosthetics. , 2004, Annual review of neuroscience.

[20]  J. Donoghue,et al.  Brain–Machine and Brain–Computer Interfaces , 2004, Stroke.

[21]  David J. Anderson,et al.  Electrochemical deposition and characterization of conducting polymer polypyrrole/PSS on multichannel neural probes , 2001 .

[22]  G. Clark ELECTRICAL STIMULATION OF THE AUDITORY NERVE: THE CODING OF FREQUENCY, THE PERCEPTION OF PITCH AND THE DEVELOPMENT OF COCHLEAR IMPLANT SPEECH PROCESSING STRATEGIES FOR PROFOUNDLY DEAF PEOPLE , 1996, Clinical and experimental pharmacology & physiology.

[23]  R. Compton,et al.  AFM studies of polypyrrole film surface morphology I. The influence of film thickness and dopant nature , 1998 .

[24]  J. Jankovic,et al.  The effect of deep brain stimulation on quality of life in movement disorders , 2005, Journal of Neurology, Neurosurgery & Psychiatry.

[25]  J. McHardy,et al.  Electrical stimulation with Pt electrodes. VII. Dissolution of Pt electrodes during electrical stimulation of the cat cerebral cortex , 1983, Journal of Neuroscience Methods.

[26]  Qi Hong,et al.  AFM studies of polypyrrole film surface morphology II. Roughness characterization by the fractal dimension analysis , 1998 .

[27]  J. Weiland,et al.  Retinal prosthesis for the blind. , 2002, Survey of ophthalmology.

[28]  Manjunatha Mahadevappa,et al.  Assessment of Retinal Nerve Fiber Layer Thickness by Use of Optical Coherence Tomography and Retinal Dichroïsm Measurement: Preliminary Study , 2003 .

[29]  David C. Martin,et al.  Electrochemical deposition and characterization of poly(3,4-ethylenedioxythiophene) on neural microelectrode arrays , 2003 .

[30]  T.L. Rose,et al.  Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses (neuronal application) , 1990, IEEE Transactions on Biomedical Engineering.

[31]  W. Kenan,et al.  Impedance Spectroscopy: Emphasizing Solid Materials and Systems , 1987 .

[32]  David C. Martin,et al.  Electrochemical polymerization and properties of PEDOT/S-EDOT on neural microelectrode arrays , 2004 .

[33]  David C. Martin,et al.  Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film , 2006, Journal of neural engineering.

[34]  Wentai Liu,et al.  Retinal Prosthesis , 2018, Essentials in Ophthalmology.

[35]  Stuart F Cogan,et al.  Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation , 2004, Journal of Neuroscience Methods.

[36]  A. Ivaska,et al.  Electrochemical impedance spectroscopy of oxidized poly(3,4-ethylenedioxythiophene) film electrodes in aqueous solutions , 2000 .

[37]  James D. Weiland,et al.  In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes , 2002, IEEE Transactions on Biomedical Engineering.