Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects

Seismocardiogram (SCG) is the measure of the micro-vibrations produced by the heart contraction and blood ejection into the vascular tree. Over time, a large body of evidence has been collected on the ability of SCG to reflect cardiac mechanical events such as opening and closure of mitral and aortic valves, atrial filling and point of maximal aortic blood ejection. We recently developed a smart garment, named MagIC-SCG, that allows the monitoring of SCG, electrocardiogram (ECG) and respiration out of the laboratory setting in ambulant subjects. The present pilot study illustrates the results of two different experiments performed to obtain a first evaluation on whether a dynamical assessment of indexes of cardiac mechanics can be obtained from SCG recordings obtained by MagIC-SCG. In the first experiment, we evaluated the consistency of the estimates of two indexes of cardiac contractility, the pre-ejection period, PEP, and the left ventricular ejection time, LVET. This was done in the lab, by reproducing an experimental protocol well known in literature, so that our measures derived from SCG could have been compared with PEP and LVET reference values obtained by traditional techniques. Six healthy subjects worn MagIC-SCG while assuming two different postures (supine and standing); PEP was estimated as the time interval between the Q wave in ECG and the SCG wave corresponding to the opening of aortic valve; LVET was the time interval between the SCG waves corresponding to the opening and closure of the aortic valve. The shift from supine to standing posture produced a significant increase in PEP and PEP/LVET ratio, a reduction in LVET and a concomitant rise in the LF/HF ratio in the RR interval (RRI) power spectrum. These results are in line with data available in literature thus providing a first support to the validity of our estimates. In the second experiment, we evaluated in one subject the feasibility of the beat-by-beat assessment of LVET during spontaneous behavior. The subject was continuously monitored by the smart garment from 8 am to 8 pm during a workday. From the whole recording, three data segments were selected: while the subject was traveling to work (M1), during work in the office (O) and while traveling back home (M2). LVET was estimated on a beat-by-beat basis from SCG and the RRI influence was removed by regression analysis. The LVET series displayed marked beat-by-beat fluctuations at the respiratory frequency. The amplitude of these fluctuations changed in the three periods and was lower when the LF/HF RRI power ratio was higher, at O, thus suggesting a possible influence of the autonomic nervous system on LVET short-term variability. To the best of our knowledge this case report provides for the first time a representation of the beat-by-beat dynamics of a systolic time interval during daily activity. The statistical characterization of these findings remains to be explored on a larger population.

[1]  A. Weissler,et al.  Systolic Time Intervals in Heart Failure in Man , 1968, Circulation.

[2]  M Paiva,et al.  Three-dimensional ballistocardiography and respiratory motion in sustained microgravity. , 2001, Aviation, space, and environmental medicine.

[3]  Gregory T. A. Kovacs,et al.  Ballistocardiography — A method worth revisiting , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  D. Salerno,et al.  Seismocardiography for monitoring changes in left ventricular function during ischemia. , 1991, Chest.

[5]  W. J. Walker Ballistocardiography in Cardiovascular Research. , 1968 .

[6]  P S Reddy,et al.  Direct Correlation of External Systolic Time Intervals with Internal Indices of Left Ventricular Function in Man , 1971, Circulation.

[7]  G. Parati,et al.  Wearable Seismocardiography , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  K Tavakolian,et al.  Comparative analysis of infrasonic cardiac signals , 2009, 2009 36th Annual Computers in Cardiology Conference (CinC).

[9]  P H Gregson,et al.  Sternal acceleration ballistocardiography and arterial pressure wave analysis to determine stroke volume. , 1999, Clinical and investigative medicine. Medecine clinique et experimentale.

[10]  G. Parati,et al.  Evaluation of a textile-based wearable system for the electrocardiogram monitoring in cardiac patients. , 2013, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[11]  D. Spodick,et al.  Heart rate--left ventricular ejection time relations. Variations during postural change and cardiovascular challenges. , 1976, British heart journal.

[12]  S. M. Debbal,et al.  Computerized heart sounds analysis , 2008, Comput. Biol. Medicine.

[13]  Jamil Tajik,et al.  The return of cardiac time intervals: the phoenix is rising. , 2003, Journal of the American College of Cardiology.

[14]  G. Belz,et al.  Systolic time intervals in clinical pharmacology , 2004, European Journal of Clinical Pharmacology.

[15]  A. Malliani,et al.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use , 1996 .

[16]  Erwan Donal,et al.  Systolic time intervals as simple echocardiographic parameters of left ventricular systolic performance: correlation with ejection fraction and longitudinal two-dimensional strain. , 2010, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[17]  A. Weissler,et al.  Bedside technics for the evaluation of ventricular function in man. , 1969, The American journal of cardiology.

[18]  W. Jones,et al.  DETERMINANTS OF DURATION OF LEFT VENTRICULAR EJECTION IN NORMAL YOUNG MEN. , 1964, Journal of applied physiology.

[19]  Peter Ott,et al.  Accelerometer‐Derived Time Intervals during Various Pacing Modes in Patients with Biventricular Pacemakers: Comparison with Normals , 2007, Pacing and clinical electrophysiology : PACE.

[20]  G. N. Webb,et al.  On Cardiovascular Sound: Further Observations by Means of Spectral Phonocardiography , 1955, Circulation.

[21]  J. M. Zanetti,et al.  Exercise seismocardiography for detection of coronary artery disease , 1992 .

[22]  Xavier Neyt,et al.  Three dimensional ballistocardiography: Methodology and results from microgravity and dry immersion , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  E. J. Geus,et al.  Effects of variation in posture and respiration on RSA and pre-ejection period. , 2005, Psychophysiology.

[24]  Francesco Rizzo,et al.  Textile Technology for the Vital Signs Monitoring in Telemedicine and Extreme Environments , 2010, IEEE Transactions on Information Technology in Biomedicine.

[25]  Francesco Rizzo,et al.  A wearable system for the seismocardiogram assessment in daily life conditions , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[26]  B S BOZHENKO,et al.  [Seismocardiography--a new method in the study of functional conditions of the heart]. , 1961, Terapevticheskii arkhiv.

[27]  Francesco Faita,et al.  Transthoracic Sensor for Noninvasive Assessment of Left Ventricular Contractility: Validation in A Minipig Model of Chronic Heart Failure , 2010, Pacing and clinical electrophysiology : PACE.

[28]  Francesco Rizzo,et al.  24h seismocardiogram monitoring in ambulant subjects , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[29]  Bozena Kaminska,et al.  Comparative analysis of seismocardiogram waves with the ultra-low frequency ballistocardiogram , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[30]  C. Wooley,et al.  Effect of acute standing and prolonged upright activity on left ventricular hemodynamics, systolic and diastolic intervals, and QT-QS2 relationship. , 1985, American heart journal.

[31]  C. Tei,et al.  New non-invasive index for combined systolic and diastolic ventricular function. , 1995, Journal of cardiology.

[32]  R A Wilson,et al.  Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing. , 1993, The American journal of cardiology.

[33]  Bozhenko Bs [Seismocardiography--a new method in the study of functional conditions of the heart]. , 1961 .

[34]  Francesco Faita,et al.  Arterial pressure changes monitoring with a new precordial noninvasive sensor , 2008, Cardiovascular ultrasound.

[35]  Viatcheslav Gurev,et al.  Mechanisms Underlying Isovolumic Contraction and Ejection Peaks in Seismocardiogram Morphology. , 2012, Journal of medical and biological engineering.

[36]  Peter J. Hannan,et al.  Relationship between seismocardiogram and echocardiogram for events in the cardiac cycle , 1994 .

[37]  G. Skolidis,et al.  Automatic classification of arrhythmic beats using Gaussian Processes , 2008, 2008 Computers in Cardiology.

[38]  Francesco Rizzo,et al.  Cardiac sounds from a wearable device for sternal seismocardiography , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.