NPIP: A skew line needle configuration optimization system for HDR brachytherapy.

PURPOSE In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. METHODS NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the final needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, δ. The candidate needle set consisted of 5000 needles, and a range of δ values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. RESULTS NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of δ values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. CONCLUSIONS The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many or fewer needles than the current HDR brachytherapy workflow. Combined with robot assisted brachytherapy, this system has the potential to reduce side effects associated with treatment. A physical trial should be done to test the implant feasibility of NPIP needle configurations.

[1]  Alper Atamtürk,et al.  IPIP: A new approach to inverse planning for HDR brachytherapy by directly optimizing dosimetric indices. , 2010, Medical physics.

[2]  K Cleary,et al.  Precision placement of instruments for minimally invasive procedures using a “needle driver” robot , 2005, The international journal of medical robotics + computer assisted surgery : MRCAS.

[3]  G. Gustafson,et al.  A new model using number of needles and androgen deprivation to predict chronic urinary toxicity for high or low dose rate prostate brachytherapy. , 2005, The Journal of urology.

[4]  Laurence A. Wolsey,et al.  Integer and Combinatorial Optimization , 1988 .

[5]  L. Devroye Non-Uniform Random Variate Generation , 1986 .

[6]  D. Stoianovici,et al.  Transperineal prostate intervention: robot for fully automated MR imaging--system description and proof of principle in a canine model. , 2008, Radiology.

[7]  L. Kochian Author to whom correspondence should be addressed , 2006 .

[8]  J. Pouliot,et al.  Phase II trial of combined high-dose-rate brachytherapy and external beam radiotherapy for adenocarcinoma of the prostate: preliminary results of RTOG 0321. , 2008, International journal of radiation oncology, biology, physics.

[9]  R. Munarriz,et al.  Blunt trauma: the pathophysiology of hemodynamic injury leading to erectile dysfunction. , 1995, The Journal of urology.

[10]  J. Pouliot,et al.  Measurement of craniocaudal catheter displacement between fractions in computed tomography–based high dose rate brachytherapy of prostate cancer , 2007, Journal of applied clinical medical physics.

[11]  J. Pouliot,et al.  Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns. , 2008, Medical physics.

[12]  Yongde Zhang,et al.  Evaluation of robotic needle insertion in conjunction with in vivo manual insertion in the operating room , 2005, ROMAN 2005. IEEE International Workshop on Robot and Human Interactive Communication, 2005..

[13]  E. W. Shrigley Medical Physics , 1944, British medical journal.

[14]  Peter Kazanzides,et al.  Robotic assistance for ultrasound-guided prostate brachytherapy , 2008, Medical Image Anal..

[15]  W. J. Morris,et al.  Predictive factors for erectile dysfunction in men with prostate cancer after brachytherapy: is dose to the penile bulb important? , 2005, International journal of radiation oncology, biology, physics.

[16]  Luc Beaulieu,et al.  An eight-year experience of HDR brachytherapy boost for localized prostate cancer: biopsy and PSA outcome. , 2007, International journal of radiation oncology, biology, physics.

[17]  Patrick W McLaughlin,et al.  Vessel-sparing prostate radiotherapy: dose limitation to critical erectile vascular structures (internal pudendal artery and corpus cavernosum) defined by MRI. , 2005, International journal of radiation oncology, biology, physics.

[18]  J. Cygler,et al.  Correlating the degree of needle trauma during prostate brachytherapy and the development of acute urinary toxicity. , 2004, International journal of radiation oncology, biology, physics.

[19]  Yongde Zhang,et al.  Robot-Assisted Prostate Brachytherapy , 2006, MICCAI.

[20]  Alexandru Patriciu,et al.  “MRI Stealth” robot for prostate interventions , 2007, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[21]  Hao Su,et al.  Real-time MRI-guided needle placement robot with integrated fiber optic force sensing , 2011, 2011 IEEE International Conference on Robotics and Automation.

[22]  G. S. Gustafson,et al.  The Role of Needle Trauma in the Development of Urinary Toxicity Following Prostate High Dose Rate (HDR) Brachytherapy , 2007 .