Optimal coordination of directional overcurrent relays using a new time-current-voltage characteristic

Summary form only given. With the integration of distributed generation (DG) to meshed distribution systems, the operating time of the protective system becomes a major concern in order to avoid nuisance DG tripping. This paper proposes a new time-current-voltage tripping characteristic for directional overcurrent relays (DOCRs) that can achieve a higher possible reduction of overall relays operating time in meshed distribution networks. The proposed tripping characteristic is described in detail. Moreover, the protection coordination problem is formulated as a constrained nonlinear programming problem to determine the optimal relay settings. The proposed characteristic is tested on the power distribution system of the IEEE 14 bus and IEEE 30 bus with inverter-based and synchronous-based DG units. The outcome of this study reveals that the new tripping characteristic for DOCRs achieves notable reduction in total relays' operating time over the conventional characteristic.

[1]  Ehab F. El-Saadany,et al.  Optimal coordination of overcurrent relays using a modified particle swarm optimization , 2006 .

[2]  S. R. Bhide,et al.  Optimum Coordination of Directional Overcurrent Relays Using the Hybrid GA-NLP Approach , 2011, IEEE Transactions on Power Delivery.

[3]  A. J. Urdaneta,et al.  Optimal coordination of directional overcurrent relays considering dynamic changes in the network topology , 1997 .

[4]  J. Jager,et al.  Advanced Coordination Method for Overcurrent Protection Relays Using Nonstandard Tripping Characteristics , 2008, IEEE Transactions on Power Delivery.

[5]  Hazlee Azil Illias,et al.  The study of directional overcurrent relay and directional earth-fault protection application for 33 kV underground cable system in Malaysia , 2012 .

[6]  Peter E. Sutherland Protective device coordination in an industrial power system with multiple sources , 1996 .

[7]  J. Lewis Blackburn,et al.  Protective Relaying: Principles And Applications , 2006 .

[8]  H.O. Gupta,et al.  A new nonlinear directional overcurrent relay coordination technique, and banes and boons of near-end faults based approach , 2006, IEEE Transactions on Power Delivery.

[9]  Wei Lee Woon,et al.  Optimal Protection Coordination for Microgrids With Grid-Connected and Islanded Capability , 2012 .

[10]  J. Horak,et al.  Directional Overcurrent Relaying (67) Concepts , 2006, 2006 IEEE Rural Electric Power Conference.

[11]  R. Kaczmarek,et al.  Coordination of directional overcurrent relays using a novel method to select their settings , 2011 .

[12]  A. J. Urdaneta,et al.  Coordination of directional overcurrent relay timing using linear programming , 1996 .

[13]  Vijay S. Kale,et al.  Optimum coordination of overcurrent relays in distribution system using genetic algorithm , 2009, 2009 International Conference on Power Systems.

[14]  C. R. Mason,et al.  The Art and Science of Protective Relaying , 1956 .

[15]  S.F. Mekhamer,et al.  A Modified Particle Swarm Optimizer for the Coordination of Directional Overcurrent Relays , 2007, IEEE Transactions on Power Delivery.

[16]  Weidong Xiao,et al.  Determining Optimal Location and Size of Distributed Generation Resources Considering Harmonic and Protection Coordination Limits , 2013, IEEE Transactions on Power Systems.

[17]  A. J. Urdaneta,et al.  Optimal coordination of directional overcurrent relays in interconnected power systems , 1988 .

[18]  Yasser Abdel-Rady I. Mohamed,et al.  A Protection Coordination Index for Evaluating Distributed Generation Impacts on Protection for Meshed Distribution Systems , 2013, IEEE Transactions on Smart Grid.

[19]  David Costello,et al.  Fundamentals and improvements for directional relays , 2010, 2010 63rd Annual Conference for Protective Relay Engineers.

[20]  G.T. Heydt,et al.  Fault Current Contribution From Synchronous Machine and Inverter Based Distributed Generators , 2007, IEEE Transactions on Power Delivery.

[21]  H. R. Mashhadi,et al.  Optimal Coordination of Directional Overcurrent Relays Considering Different Network Topologies Using Interval Linear Programming , 2010, IEEE Transactions on Power Delivery.

[22]  C.-W. So,et al.  Time coordination method for power system protection by evolutionary algorithm , 1999 .

[23]  A. J. Urdaneta,et al.  Presolve analysis and interior point solutions of the linear programming coordination problem of directional overcurrent relays , 2001 .

[24]  J. Sadeh,et al.  Considering Different Network Topologies in Optimal Overcurrent Relay Coordination Using a Hybrid GA , 2009, IEEE Transactions on Power Delivery.

[25]  M. S. Sachdev,et al.  An on-line relay coordination algorithm for adaptive protection using linear programming technique , 1996 .

[26]  B Hussain,et al.  Impact studies of distributed generation on power quality and protection setup of an existing distribution network , 2010, SPEEDAM 2010.

[27]  T.S. Sidhu,et al.  Restoration of Directional Overcurrent Relay Coordination in Distributed Generation Systems Utilizing Fault Current Limiter , 2008, IEEE Transactions on Power Delivery.

[28]  Jen-Hao Teng,et al.  Unsymmetrical Short-Circuit Fault Analysis for Weakly Meshed Distribution Systems , 2010, IEEE Transactions on Power Systems.