A novel guidewire‐integrated embolic protection filter device with a handy‐folding system: In vitro and in vivo performance assessment
暂无分享,去创建一个
Takeshi Kimura | Hiroki Watanabe | N. Saito | J. Tazaki | Shin Watanabe | E. Yamamoto | Kanji Inoue | Bingyuan Bao | K. Nakatsuma | Yoshimasa Nagata | B. Bingyuan | Naritatsu Saito | Erika Yamamoto | Kenji Nakatsuma
[1] M. Leon,et al. Randomized Trial of a Distal Embolic Protection Device During Percutaneous Intervention of Saphenous Vein Aorto-Coronary Bypass Grafts , 2002, Circulation.
[2] F. Neumann,et al. Randomized Evaluation of the Effects of Filter-Based Distal Protection on Myocardial Perfusion and Infarct Size After Primary Percutaneous Catheter Intervention in Myocardial Infarction With and Without ST-Segment Elevation , 2005, Circulation.
[3] J. Carrozza,et al. Randomized evaluation of the TriActiv balloon-protection flush and extraction system for the treatment of saphenous vein graft disease. , 2005, Journal of the American College of Cardiology.
[4] G. Knapp,et al. Short term and intermediate term comparison of endarterectomy versus stenting for carotid artery stenosis: systematic review and meta-analysis of randomised controlled clinical trials , 2010, BMJ : British Medical Journal.
[5] L. Klein,et al. Utilization of distal embolic protection in saphenous vein graft interventions (an analysis of 19,546 patients in the American College of Cardiology-National Cardiovascular Data Registry). , 2007, The American journal of cardiology.
[6] H. Jäger,et al. New ischaemic brain lesions on MRI after stenting or endarterectomy for symptomatic carotid stenosis: a substudy of the International Carotid Stenting Study (ICSS) , 2010, Lancet Neurology.
[7] K. Kozuma,et al. Comparison of myocardial perfusion by distal protection before and after primary stenting for acute myocardial infarction: Angiographic and clinical results of a randomized controlled trial , 2007, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.
[8] R. Gibbons,et al. Distal Microcirculatory Protection During Percutaneous Coronary Intervention in Acute ST-Segment Elevation Myocardial Infarction: A Randomized Controlled Trial , 2005 .
[9] E. Kanal,et al. A randomized trial of carotid artery stenting with and without cerebral protection. , 2008, Journal of vascular surgery.
[10] E. Finol,et al. A Comparative Analysis of Bench-Top Performance Assessment of Distal Protection Filters in Transient Flow Conditions , 2012, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.
[11] Sunil V. Rao,et al. Frequency and predictors of drug-eluting stent use in saphenous vein bypass graft percutaneous coronary interventions: a report from the American College of Cardiology National Cardiovascular Data CathPCI registry. , 2010, JACC. Cardiovascular interventions.
[12] Michael D Hill,et al. Stenting versus endarterectomy for treatment of carotid-artery stenosis. , 2010, The New England journal of medicine.
[13] R. Gibbons,et al. Distal microcirculatory protection during percutaneous coronary intervention in acute ST-segment elevation myocardial infarction: a randomized controlled trial. , 2005, JAMA.
[14] C. Terkelsen,et al. Randomized comparison of distal protection versus conventional treatment in primary percutaneous coronary intervention: the drug elution and distal protection in ST-elevation myocardial infarction (DEDICATION) trial. , 2008, Journal of the American College of Cardiology.
[15] R. Sakata,et al. A novel detachable filter to prevent thromboembolism during endovascular surgery. , 2012, The Journal of thoracic and cardiovascular surgery.