Accurate mass filtering of ion chromatograms for metabolite identification using a unit mass resolution liquid chromatography/mass spectrometry system.

Acceleration of liquid chromatography/mass spectrometric (LC/MS) analysis for metabolite identification critically relies on effective data processing since the rate of data acquisition is much faster than the rate of data mining. The rapid and accurate identification of metabolite peaks from complex LC/MS data is a key component to speeding up the process. Current approaches routinely use selected ion chromatograms that can suffer severely from matrix effects. This paper describes a new method to automatically extract and filter metabolite-related information from LC/MS data obtained at unit mass resolution in the presence of complex biological matrices. This approach is illustrated by LC/MS analysis of the metabolites of verapamil from a rat microsome incubation spiked with biological matrix (bile). MS data were acquired in profile mode on a unit mass resolution triple-quadrupole instrument, externally calibrated using a unique procedure that corrects for both mass axis and mass spectral peak shape to facilitate metabolite identification with high mass accuracy. Through the double-filtering effects of accurate mass and isotope profile, conventional extracted ion chromatograms corresponding to the parent drug (verapamil at m/z 455), demethylated verapamil (m/z 441), and dealkylated verapamil (m/z 291), that contained substantial false-positive peaks, were simplified into chromatograms that are substantially free from matrix interferences. These filtered chromatograms approach what would have been obtained by using a radioactivity detector to detect radio-labeled metabolites of interest.

[1]  U. Hofmann,et al.  Rapid and highly sensitive method for the determination of verapamil, [2H7]verapamil and metabolites in biological fluids by liquid chromatography-mass spectrometry. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[2]  D. Zhong,et al.  In vitro identification of metabolites of verapamil in rat liver microsomes. , 2004, Acta pharmacologica Sinica.

[3]  P. Ferguson,et al.  Using a triple-quadrupole mass spectrometer in accurate mass mode and an ion correlation program to identify compounds. , 2005, Rapid communications in mass spectrometry : RCM.

[4]  Donglu Zhang,et al.  A software filter to remove interference ions from drug metabolites in accurate mass liquid chromatography/mass spectrometric analyses. , 2003, Journal of mass spectrometry : JMS.

[5]  K. Blom Estimating the precision of exact mass measurements on an orthogonal time-of-flight mass spectrometer. , 2001, Analytical chemistry.

[6]  R. N. Brogden,et al.  Verapamil: a review of its pharmacological properties and therapeutic use in coronary artery disease. , 1996, Drugs.

[7]  R. Ramanathan,et al.  Using mass spectrometry for drug metabolism studies , 2006, Journal of the American Society for Mass Spectrometry.

[8]  G. Glish,et al.  Mass spectrometry/mass spectrometry: techniques and applications of tandem mass spectrometry , 1990 .

[9]  F. Clarke,et al.  Chemical image fusion. The synergy of FT-NIR and Raman mapping microscopy to enable a more complete visualization of pharmaceutical formulations. , 2001, Analytical chemistry.

[10]  M. Jekel,et al.  Exact mass measurements on-line with high-performance liquid chromatography on a quadrupole mass spectrometer. , 2001, Analytical chemistry.

[11]  E. Kantharaj,et al.  Simultaneous measurement of drug metabolic stability and identification of metabolites using ion-trap mass spectrometry. , 2003, Rapid communications in mass spectrometry : RCM.