CAD-based Displacement Measurements with Stereo-DIC

A new displacement measurement technique is proposed in a stereovision setup, which uses the object of interest as the support of the correlation process. This procedure leads to a global approach to stereocorrelation. The method is presented in its general formulation and is then particularized to the case of non uniform rational B-splines (NURBS). The displacement field is directly measured as a 3D field expressed in a NURBS basis consistent with the existing geometric model. The kinematic measurements are validated against prescribed displacements of a machined Bézier patch. The feasibility in an industrial context is shown with the analysis of 3D displacement fields of a 2- m2 automotive roof panel during a welding operation.

[1]  Ramesh C. Jain,et al.  Scanning electron microscope-based stereo analysis , 2005, Machine Vision and Applications.

[2]  Thomas J. R. Hughes,et al.  Isogeometric Analysis: Toward Integration of CAD and FEA , 2009 .

[3]  A. N. Tikhonov,et al.  Solutions of ill-posed problems , 1977 .

[4]  J. Orteu,et al.  Quantitative Stereovision in a Scanning Electron Microscope , 2011 .

[5]  Michael A. Sutton,et al.  Application of stereo vision to three-dimensional deformation analyses in fracture experiments , 1994 .

[6]  Jean-Philippe Pons,et al.  Towards high-resolution large-scale multi-view stereo , 2009, 2009 IEEE Conference on Computer Vision and Pattern Recognition.

[7]  Stéphane Roux,et al.  Identification of a set of macroscopic elastic parameters in a 3D woven composite: Uncertainty analysis and regularization , 2015 .

[8]  S. Roux,et al.  Mechanics-aided digital image correlation , 2013 .

[9]  S. Roux,et al.  Comparison of Local and Global Approaches to Digital Image Correlation , 2012 .

[10]  Stéphane Roux,et al.  Estimation of Elastoplastic Parameters via Weighted FEMU and Integrated-DIC , 2015 .

[11]  Stéphane Roux,et al.  Voxel-Scale Digital Volume Correlation , 2011 .

[12]  B. Beaubier,et al.  CAD-based calibration and shape measurement with stereoDIC , 2014 .

[13]  Les A. Piegl,et al.  The NURBS Book , 1995, Monographs in Visual Communication.

[14]  Paul R. Cohen,et al.  Camera Calibration with Distortion Models and Accuracy Evaluation , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[15]  Hubert W. Schreier,et al.  Image Correlation for Shape, Motion and Deformation Measurements: Basic Concepts,Theory and Applications , 2009 .

[16]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[17]  Stéphane Roux,et al.  Digital Image Correlation , 2012 .

[18]  Jeffrey D. Helm,et al.  Improved three-dimensional image correlation for surface displacement measurement , 1996 .

[19]  Satoru Yoneyama,et al.  DIGITAL IMAGE CORRELATION , 2011 .

[20]  S. P. Mudur,et al.  Three-dimensional computer vision: a geometric viewpoint , 1993 .

[21]  François Hild,et al.  Mesh-Based Shape Measurements with Stereocorrelation , 2016 .

[22]  Jean-Philippe Pons,et al.  High Accuracy and Visibility-Consistent Dense Multiview Stereo , 2012, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[23]  Richard Szeliski,et al.  A Comparison and Evaluation of Multi-View Stereo Reconstruction Algorithms , 2006, 2006 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'06).

[24]  Gérard G. Medioni,et al.  Object modelling by registration of multiple range images , 1992, Image Vis. Comput..

[25]  Michael A. Sutton,et al.  Digital Image Correlation for Shape and Deformation Measurements , 2008 .

[26]  Michael A. Sutton,et al.  Computer Vision-Based, Noncontacting Deformation Measurements in Mechanics: A Generational Transformation , 2013 .

[27]  Yuh J. Chao,et al.  Advances in Two-Dimensional and Three-Dimensional Computer Vision , 2000 .

[28]  Stéphane Roux,et al.  Integrated Digital Image Correlation for the Evaluation and Correction of Optical Distortions , 2014 .

[29]  S M Lessner,et al.  Strain field measurements on mouse carotid arteries using microscopic three-dimensional digital image correlation. , 2008, Journal of biomedical materials research. Part A.

[30]  Michael A. Sutton,et al.  The effect of out-of-plane motion on 2D and 3D digital image correlation measurements , 2008 .

[31]  Stéphane Roux,et al.  Stress intensity factor measurements from digital image correlation: post-processing and integrated approaches , 2006 .

[32]  Stéphane Roux,et al.  3D surface measurements with isogeometric stereocorrelation—Application to complex shapes , 2016 .

[33]  Michael A. Sutton,et al.  Advances in light microscope stereo vision , 2004 .

[34]  Stéphane Roux,et al.  Shape, displacement and mechanical properties from isogeometric multiview stereocorrelation , 2015 .

[35]  S. Roux,et al.  Analysis of necking in high speed experiments by stereocorrelation , 2012 .

[36]  Stéphane Roux,et al.  Digital volume correlation: what are the limits to the spatial resolution? , 2012 .

[37]  Stéphane Roux,et al.  Integrated Digital Image Correlation for the Identification of Mechanical Properties , 2009, MIRAGE.