Optimization modeling of analyte adhesion over an inclined microcantilever-based biosensor

The effect of the microcantilever inclination on analyte adhesion is numerically analyzed in this work. A generalized model for the analyte adhesion is considered based on wall shear stress (WSS) at the microcantilever surface. Several analytical solutions for special cases are obtained. It is found numerically that the total mass transfer is enhanced by increasing the adhesion rate, the Peclet number and the use of converging flows over the microcantilever. Further, it is found that there exists a critical Peclet number that can maximize the total mass transfer when WSS slows down the adhesion process. The critical Peclet number increases as adhesion rate increases while it decreases as the flow becomes more convergent. Correlations are established on the basis of the numerical simulations for predicting flow operating conditions inside fluidic cells under maximized mass transfer rate conditions. Finally, this work paves the way for future experimental work in this area.

[1]  Scott I. Simon,et al.  Leukocyte Adhesion Dynamics in Shear Flow , 2002, Annals of Biomedical Engineering.

[2]  Cengiz S. Ozkan,et al.  Analysis, control and augmentation of microcantilever deflections in bio-sensing systems , 2003 .

[3]  A.-R. A. Khaleda,et al.  Analysis , control and augmentation of microcantilever deflections in bio-sensing systems , 2003 .

[4]  D. Giddens,et al.  Effects of wall shear stress and fluid recirculation on the localization of circulating monocytes in a three-dimensional flow model. , 1995, Journal of biomechanics.

[5]  Inseob Song,et al.  Fabrication of a microchannel integrated with inner sensors and the analysis of its laminar flow characteristics , 2003 .

[6]  A K Chakraborty,et al.  Origin of nanomechanical cantilever motion generated from biomolecular interactions. , 2001, Proceedings of the National Academy of Sciences of the United States of America.

[7]  H. Rothuizen,et al.  Translating biomolecular recognition into nanomechanics. , 2000, Science.

[8]  K. Vafai,et al.  Analysis of oscillatory flow disturbances and thermal characteristics inside fluidic cells due to fluid leakage and wall slip conditions. , 2004, Journal of biomechanics.

[9]  F. Blottner,et al.  FINITE DIFFERENCE METHODS OF SOLUTION OF THE BOUNDARY-LAYER EQUATIONS , 1970 .

[10]  J. Anderson,et al.  Leukocyte-biomaterial interactions in the presence of Staphylococcus epidermidis: flow cytometric evaluation of leukocyte activation. , 1997, Journal of biomedical materials research.

[11]  T David,et al.  Platelet deposition in stagnation point flow: an analytical and computational simulation. , 2001, Medical engineering & physics.

[12]  K. Khanafer,et al.  Spatial optimization of an array of aligned microcantilever based sensors , 2004 .

[13]  Mamoru Tanaka,et al.  Drag coefficient of a capsule inside a vertical angular pipe , 1997 .

[14]  Roberto Raiteri,et al.  Sensing of biological substances based on the bending of microfabricated cantilevers , 1999 .

[15]  Cengiz S. Ozkan,et al.  High sensitivity piezoresistive cantilever design and optimization for analyte-receptor binding , 2003 .