Stochastic Assessment of Voltage Unbalance Mitigation by Home Battery System in Low Voltage Grid with Single-Phase Solar Power Generation

Modern electrical power system is evolving to a smarter and agile system, which will support society's sustainable development. The low voltage grid should be capable of withstanding new challenges such as reverse power flows and voltage unbalance (VU) caused by distributed generation. In this paper, the mitigation possibilities of the VU caused by single-phase-connected photovoltaics (PV) are analysed with Tesla Powerwall 2 battery energy storage systems (BESS) added to the grid. Three different BESS phase connection strategies are modelled and the VU is assessed with Monte Carlo Simulation (MCS). A low voltage distribution grid in Sweden is considered with different PV and BESS penetration levels and the applied method for VU assessment is validated. Simulation results reveal the effectiveness of VU mitigation by connecting PV and BESS to the same phase.

[1]  Марина Володимирівна Рудіна,et al.  Переклад англомовного варіанту міжнародного документу “Directive 2009/28/EC of the european parliament and of the council of 23 April 2009 on the promotion of the use of energy renewable sources” українською мовою як навчальний ресурс літньої практики студентів-перекладачів , 2018 .

[2]  P. Hiralal,et al.  Batteries as a Service: A New Look at Electricity Peak Demand Management for Houses in the UK☆ , 2016 .

[3]  Jan Meyer,et al.  Stochastic assessment of voltage unbalance due to single-phase-connected solar power , 2016, 2016 17th International Conference on Harmonics and Quality of Power (ICHQP).

[4]  F. Katiraei,et al.  INTEGRATION OF PHOTOVOLTAIC POWER SYSTEMS IN HIGH-PENETRATION CLUSTERS FOR DISTRIBUTION NETWORKS AND MINI-GRIDS , 2007 .

[5]  Francisco Jurado,et al.  Voltage unbalance assessment in secondary radial distribution networks with single-phase photovoltaic systems , 2015 .

[6]  Math Bollen,et al.  Integration of Distributed Generation in the Power System , 2008 .

[7]  R. M. Ciric,et al.  EVALUATION OF DISTRIBUTION SYSTEM LOSSES DUE TO LOAD UNBALANCE , 2005 .

[8]  Farhad Shahnia,et al.  Stochastic analysis results for coordination of single-phase rooftop PVs in unbalanced residential feeders , 2015, 2015 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC).

[9]  Furong Li,et al.  Quantification of Additional Asset Reinforcement Cost From 3-Phase Imbalance , 2016, IEEE Transactions on Power Systems.

[10]  Roger Fouquet,et al.  Path dependence in energy systems and economic development , 2016, Nature Energy.

[11]  D. H. Harrison Voltage unbalance on rural systems , 1987 .

[12]  H. Farhangi,et al.  The path of the smart grid , 2010, IEEE Power and Energy Magazine.