Fiber microelectrodes for electrophysiological recordings

Methods for the fabrication of tungsten-glass and platinum-rhodium-quartz fiber microelectrodes and of fiber pipettes are described and the electrical and mechanical properties of fiber electrodes are discussed. These properties (minimal tissue damage, good single unit isolation and temporal stability) make them particularly suited for multielectrode recordings from the central nervous system.

[1]  K. Wise,et al.  An integrated-circuit approach to extracellular microelectrodes. , 1970, IEEE transactions on bio-medical engineering.

[2]  D. Robinson,et al.  The electrical properties of metal microelectrodes , 1968 .

[3]  Heribert J. P. Reitboeck,et al.  A 19-channel matrix drive with individually controllable fiber microelectrodes for neurophysiological applications , 1983, IEEE Transactions on Systems, Man, and Cybernetics.

[4]  J Y Lettvin,et al.  Glass-Coated Tungsten Microelectrodes , 1965, Science.

[5]  E. Marg A Rugged, Reliable and Sterilizable Microelectrode for recording Single Units from the Brain , 1964, Nature.

[6]  Harry Grundfest,et al.  Stainless Steel Micro‐Needle Electrodes Made by Electrolytic Pointing , 1950 .

[7]  J. Krüger A 12-fold microelectrode for recording from vertically aligned cortical neurones , 1982, Journal of Neuroscience Methods.

[8]  G. F. Taylor A Method of Drawing Metallic Filaments and a Discussion of their Properties and Uses , 1924 .

[9]  M L Wolbarsht,et al.  Glass Insulated Platinum Microelectrode , 1960, Science.

[10]  J. Y. Lettvin,et al.  Comments on Microelectrodes , 1959, Proceedings of the IRE.

[11]  C D Ferris,et al.  Electrode-produced signal distortion in electrophysiological recording systems. , 1974, IEEE transactions on bio-medical engineering.

[12]  H J Reitboeck,et al.  Color-dependent distribution of spikes in single optic tract fibers of the cat. , 1974, Vision research.

[13]  D. Hubel Tungsten Microelectrode for Recording from Single Units. , 1957, Science.

[14]  O. VATTER,et al.  Herstellung von Metallmikroelektroden für Forschung und Klinik , 1969 .

[15]  Kensall D. Wise,et al.  A Low-Capacitance Multielectrode Probe for Use in Extracellular Neurophysiology , 1975, IEEE Transactions on Biomedical Engineering.

[16]  Michel Keddam,et al.  Faradaic Impedances: Diffusion Impedance and Reaction Impedance , 1970 .

[17]  K. Frank,et al.  CHAPTER 2 – MICROELECTRODES FOR RECORDING AND STIMULATION , 1964 .

[18]  Tungsten microneedles: a simple method of production. , 1972, Electroencephalography and clinical neurophysiology.