Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system.

Fat suppression is an important technique in musculoskeletal imaging to improve the visibility of bone-marrow lesions; evaluate fat in soft-tissue masses; optimize the contrast-to-noise ratio in magnetic resonance (MR) arthrography; better define lesions after administration of contrast material; and avoid chemical shift artifacts, primarily at 3-T MR imaging. High-field-strength (eg, 3-T) MR imaging has specific technical characteristics compared with lower-field-strength MR imaging that influence the use and outcome of various fat-suppression techniques. The most commonly used fat-suppression techniques for musculoskeletal 3-T MR imaging include chemical shift (spectral) selective (CHESS) fat saturation, inversion recovery pulse sequences (eg, short inversion time inversion recovery [STIR]), hybrid pulse sequences with spectral and inversion-recovery (eg, spectral adiabatic inversion recovery and spectral attenuated inversion recovery [SPAIR]), spatial-spectral pulse sequences (ie, water excitation), and the Dixon techniques. Understanding the different fat-suppression options allows radiologists to adopt the most appropriate technique for their clinical practice.

[1]  Y. Korogi,et al.  Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL) of the wrist and finger at 3T: Comparison with chemical shift selective fat suppression images , 2013, Journal of magnetic resonance imaging : JMRI.

[2]  A. Chhabra,et al.  High-resolution 3-T MR neurography of femoral neuropathy. , 2012, AJR. American journal of roentgenology.

[3]  Y. Miki,et al.  Three-dimensional double-echo steady-state (3D-DESS) magnetic resonance imaging of the knee: establishment of flip angles for evaluation of cartilage at 1.5 T and 3.0 T , 2012, Acta radiologica.

[4]  Peter Börnert,et al.  ISMRM workshop on fat–water separation: Insights, applications and progress in MRI , 2012, Magnetic resonance in medicine.

[5]  Kenneth C. Wang,et al.  MR neurography: past, present, and future. , 2011, AJR. American journal of roentgenology.

[6]  A. Chhabra,et al.  3 Tesla MR neurography—technique, interpretation, and pitfalls , 2011, Skeletal Radiology.

[7]  Richard Kijowski,et al.  3.0-T evaluation of knee cartilage by using three-dimensional IDEAL GRASS imaging: comparison with fast spin-echo imaging. , 2010, Radiology.

[8]  S. Reeder,et al.  Fat and water magnetic resonance imaging , 2010, Journal of magnetic resonance imaging : JMRI.

[9]  D. DeLong,et al.  Effect of echo time pair selection on quantitative analysis for adrenal tumor characterization with in-phase and opposed-phase MR imaging: initial experience. , 2008, Radiology.

[10]  Keith Heberlein,et al.  Evaluation of optimized inversion‐recovery fat‐suppression techniques for T2‐weighted abdominal MR imaging , 2008, Journal of Magnetic Resonance Imaging.

[11]  Raymond Kuo,et al.  3.0 Tesla imaging of the musculoskeletal system , 2007, Journal of magnetic resonance imaging : JMRI.

[12]  Norbert J Pelc,et al.  T1‐ and T2‐weighted fast spin‐echo imaging of the brachial plexus and cervical spine with IDEAL water–fat separation , 2006, Journal of magnetic resonance imaging : JMRI.

[13]  Norbert J Pelc,et al.  Articular cartilage of the knee: rapid three-dimensional MR imaging at 3.0 T with IDEAL balanced steady-state free precession--initial experience. , 2006, Radiology.

[14]  Norbert J Pelc,et al.  Field map estimation with a region growing scheme for iterative 3‐point water‐fat decomposition , 2005, Magnetic resonance in medicine.

[15]  G. Gold,et al.  Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imaging , 2005, Magnetic resonance in medicine.

[16]  Wilson Fong Handbook of MRI Pulse Sequences , 2005 .

[17]  Jingfei Ma,et al.  T2‐weighted spine imaging with a fast three‐point dixon technique: Comparison with chemical shift selective fat suppression , 2004, Journal of magnetic resonance imaging : JMRI.

[18]  Garry E Gold,et al.  Musculoskeletal MRI at 3.0 T: initial clinical experience. , 2004, AJR. American journal of roentgenology.

[19]  Graham Wright,et al.  Musculoskeletal MRI at 3.0 T: relaxation times and image contrast. , 2004, AJR. American journal of roentgenology.

[20]  Michael Markl,et al.  Multicoil Dixon chemical species separation with an iterative least‐squares estimation method , 2004, Magnetic resonance in medicine.

[21]  E. Dumont,et al.  Water excitation as an alternative to fat saturation in MR imaging: preliminary results in musculoskeletal imaging. , 2002, Radiology.

[22]  J. McGarry,et al.  Bulk magnetic susceptibility effects on the assessment of intra‐ and extramyocellular lipids in vivo , 2002, Magnetic resonance in medicine.

[23]  David G. Norris,et al.  Adiabatic radiofrequency pulse forms in biomedical nuclear magnetic resonance , 2002 .

[24]  R V Mulkern,et al.  Fast three-point dixon MR imaging using low-resolution images for phase correction: a comparison with chemical shift selective fat suppression for pediatric musculoskeletal imaging. , 2001, AJR. American journal of roentgenology.

[25]  F. Schick,et al.  [The MR characterization of the composition of the hematopoietic bone marrow. The findings in generalized neoplasms and the monitoring of therapy]. , 2000, Der Radiologe.

[26]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[27]  F. Schick,et al.  Association of increased intramyocellular lipid content with insulin resistance in lean nondiabetic offspring of type 2 diabetic subjects. , 1999, Diabetes.

[28]  G. Johnson,et al.  Fat suppression in MR imaging: techniques and pitfalls. , 1999, Radiographics : a review publication of the Radiological Society of North America, Inc.

[29]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[30]  C Boesch,et al.  In vivo determination of intra‐myocellular lipids in human muscle by means of localized 1H‐MR‐spectroscopy , 1997, Magnetic resonance in medicine.

[31]  F. Schick,et al.  Lipid selective MR imaging and localized 1H spectroscopy of bone marrow during therapy of leukemia. , 1996, Anticancer research.

[32]  N. Rofsky,et al.  Nonspecificity of short inversion time inversion recovery (STIR) as a technique of fat suppression: pitfalls in image interpretation. , 1996, AJR. American journal of roentgenology.

[33]  F. Schick,et al.  Magnetic resonance imaging reveals a markedly inhomogeneous distribution of marrow cellularity in a patient with myelodysplasia , 1995, Annals of Hematology.

[34]  R. Balaban,et al.  Musculoskeletal MR imaging at 4 T and at 1.5 T: comparison of relaxation times and image contrast. , 1995, Radiology.

[35]  T. McCauley,et al.  Fast Spin Echo STIR Imaging , 1994, Journal of computer assisted tomography.

[36]  F Schick,et al.  Comparison of localized proton NMR signals of skeletal muscle and fat tissue in vivo: Two lipid compartments in muscle tissue , 1993, Magnetic resonance in medicine.

[37]  G. Glover Multipoint dixon technique for water and fat proton and susceptibility imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[38]  G H Glover,et al.  Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction , 1991, Magnetic resonance in medicine.

[39]  J. Pauly,et al.  Simultaneous spatial and spectral selective excitation , 1990, Magnetic resonance in medicine.

[40]  H I Goldberg,et al.  STIR MR imaging of the orbit. , 1988, AJR. American journal of roentgenology.

[41]  P Schmalbrock,et al.  Multisection fat-water imaging with chemical shift selective presaturation. , 1987, Radiology.

[42]  G. Bydder,et al.  Clinical Use of the Partial Saturation and Saturation Recovery Sequences in MR Imaging , 1985, Journal of computer assisted tomography.

[43]  D Matthaei,et al.  1H NMR chemical shift selective (CHESS) imaging. , 1985, Physics in medicine and biology.

[44]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[45]  C. Strickland MR Arthrography of the Hip: Comparison of IDEAL-SPGR Volume Sequence to Standard MR Sequences in the Detection and Grading of Cartilage Lesions , 2012 .

[46]  B. Manaster IDEAL Imaging of the Musculoskeletal System: Robust Water–Fat Separation for Uniform Fat Suppression, Marrow Evaluation, and Cartilage Imaging , 2009 .

[47]  Matthew A Bernstein,et al.  CHAPTER 14 – BASIC PULSE SEQUENCES , 2004 .

[48]  M. Bernstein CHAPTER 4 – SPECTRAL RADIOFREQUENCY PULSES , 2004 .

[49]  M. Bernstein CHAPTER 6 – ADIABATIC RADIOFREQUENCY PULSES , 2004 .

[50]  Wendell A. Gibby,et al.  Basic Pulse Sequences , 2000 .

[51]  L. DiPietro,et al.  Intramyocellular lipid concentrations are correlated with insulin sensitivity in humans: a 1H NMR spectroscopy study , 1999, Diabetologia.

[52]  S. Williams,et al.  A chemical shift selective inversion recovery sequence for fat-suppressed MRI: theory and experimental validation. , 1993, Magnetic resonance imaging.

[53]  G M Bydder,et al.  The short TI inversion recovery sequence--an approach to MR imaging of the abdomen. , 1985, Magnetic resonance imaging.

[54]  I. Cameron Techniques of Fat Suppression , 2022 .