Study and implementation of synchronization algorithm in three phase grid connected PV system

This paper presents the study and simulation of synchronization algorithm for a three phase grid connected photovoltaic (PV) system. The synchronization algorithm employs synchronous reference frame based phase locked loop with a positive sequence detection. As compared to other methods, this algorithm provides a higher degree of immunity and insensitivity to noise and harmonic distortions. The maximum efficiency of the system may be achieved by overcoming the voltage unbalances and frequency distortion using this algorithm. The synchronization algorithm is studied by using a three phase parallel, 6 kilowatt load connected to three phase grid connected photovoltaic system.

[1]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .

[2]  C. L. Fortescue,et al.  Method of symmetrical co-ordinates applied to the solution of polyphase networks , 1918, Proceedings of the American Institute of Electrical Engineers.

[3]  F. Blaabjerg,et al.  Power electronics as efficient interface in dispersed power generation systems , 2004, IEEE Transactions on Power Electronics.

[4]  Danwei Wang,et al.  Relationship between space-vector modulation and three-phase carrier-based PWM: a comprehensive analysis [three-phase inverters] , 2002, IEEE Trans. Ind. Electron..

[5]  R. H. Park,et al.  Two-reaction theory of synchronous machines generalized method of analysis-part I , 1929, Transactions of the American Institute of Electrical Engineers.

[6]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[7]  Nobuyoshi Mutoh,et al.  A Method for MPPT Control While Searching for Parameters Corresponding to Weather Conditions for PV Generation Systems , 2004, IEEE Transactions on Industrial Electronics.

[8]  Gilles Notton,et al.  Optimal sizing of a grid-connected PV system for various PV module technologies and inclinations, inverter efficiency characteristics and locations , 2010 .

[9]  E.J. Bueno,et al.  Current control of voltage source converters connected to the grid through an LCL-filter , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[10]  M. Liserre,et al.  Evaluation of Current Controllers for Distributed Power Generation Systems , 2009, IEEE Transactions on Power Electronics.

[11]  Arnaud Rey,et al.  Real time test benchmark design for photovoltaic grid-connected control systems , 2011 .

[12]  Juan Jose Corrales Hernandez,et al.  Guidelines for the technical assessment of harmonic, flicker and unbalance emission limits for PV-di , 2011 .

[13]  N. F. Guerrero-Rodríguez,et al.  Performance study of a synchronization algorithm for a 3-phase photovoltaic grid-connected system under harmonic distortions and unbalances , 2014 .

[14]  Simone Buso,et al.  Low-Complexity MPPT Technique Exploiting the PV Module MPP Locus Characterization , 2009, IEEE Transactions on Industrial Electronics.

[15]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[16]  S. B. Gary Two-reaction theory of synchronous machines , 1937, Electrical Engineering.