Monitoring of laser and freezinginduced ablation in the liver with T1‐weighted MR imaging

During both interstitial laser ablation therapy and cryoablation therapy for liver tumors, real‐time monitoring is necessary for assessment of ongoing thermal effects in tissue. With single‐section images obtained every 30 seconds with a T1‐weighted RARE (rapid acquisition with relaxation enhancement) sequence, signal intensity changes in both ex vivo and in vivo animal liver were readily seen. The reversible loss of signal intensity that took place during laser irradiation and the increased intensity at the beginning of cooling can be explained mainly by altered T1 due to temperature change. The frozen area was seen as a sudden decrease in signal intensity at O°C due to a T2 decrease. This preliminary work showed that the protocol provides enough temporal and temperature resolution to accurately depict the extent of thermal damage, as confirmed at histologic examination. Signal intensity decreased Iinearly with temperature in the range 10°C–50°C, yielding a pixel‐to‐pixel temperature resolution of 5.37°C.

[1]  F A Jolesz,et al.  MR imaging of laser-tissue interactions. , 1988, Radiology.

[2]  D L Morris,et al.  Cryotherapy for liver metastases: A new approach , 1989, The British journal of surgery.

[3]  D L Parker,et al.  Temperature distribution measurements in two-dimensional NMR imaging. , 1983, Medical physics.

[4]  J. Overgaard,et al.  Effect of hyperthermia on malignant cells in vivo: A review and a hypothesis , 1977, Cancer.

[5]  Wr Lees,et al.  Interstitial laser hyperthermia: a new approach to local destruction of tumours. , 1989 .

[6]  T. Ravikumar,et al.  Hepatic cryosurgery with intraoperative ultrasound monitoring for metastatic colon carcinoma. , 1987, Archives of surgery.

[7]  T. Foster,et al.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. , 1984, Medical physics.

[8]  A. S. Hall,et al.  Observation by MR imaging of in vivo temperature changes induced by radio frequency hyperthermia. , 1990, Journal of computer assisted tomography.

[9]  J. Frost Receptor localization and quantification with PET. , 1988, Radiology.

[10]  F. Frank,et al.  Basic Physics and Biophysics , 1989 .

[11]  D Le Bihan,et al.  Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia. , 1989, Radiology.

[12]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[13]  F A Jolesz,et al.  Real‐time magnetic resonance imaging of laser heat deposition in tissue , 1991, Magnetic resonance in medicine.

[14]  A. S. Hall,et al.  Measurement of changes in tissue temperature using MR imaging. , 1986, Journal of computer assisted tomography.

[15]  F A Jolesz,et al.  Contrast manipulation and artifact assessment of 2D and 3D RARE sequences. , 1990, Magnetic resonance imaging.