Percutaneous Intracerebral Navigation by Duty-Cycled Spinning of Flexible Bevel-Tipped Needles

BACKGROUND:Intracerebral drug delivery using surgically placed microcatheters is a growing area of interest for potential treatment of a wide variety of neurological diseases, including tumors, neurodegenerative disorders, trauma, epilepsy, and stroke. Current catheter placement techniques are limited to straight trajectories. The development of an inexpensive system for flexible percutaneous intracranial navigation may be of significant clinical benefit. OBJECTIVE:Utilizing duty-cycled spinning of a flexible bevel-tipped needle, the authors devised and tested a means of achieving nonlinear trajectories for the navigation of catheters in the brain, which may be applicable to a wide variety of neurological diseases. METHODS:Exploiting the bending tendency of bevel-tipped needles due to their asymmetry, the authors devised and tested a means of generating curvilinear trajectories by spinning a needle with a variable duty cycle (ie, in on-off fashion). The technique can be performed using image guidance, and trajectories can be adjusted intraoperatively via joystick. Fifty-eight navigation trials were performed during cadaver testing to demonstrate the efficacy of the needle-steering system and to test its precision. RESULTS:The needle-steering system achieved a target acquisition error of 2 ± 1 mm, while demonstrating the ability to reach multiple targets from one burr hole using trajectories of varying curvature. CONCLUSION:The accuracy of the needle-steering system was demonstrated in a cadaveric model. Future studies will determine the safety of the device in vivo.

[1]  P F Morrison,et al.  Convection-enhanced delivery of macromolecules in the brain. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[2]  S. Piantadosi,et al.  Placebo-controlled trial of safety and efficacy of intraoperative controlled delivery by biodegradable polymers of chemotherapy for recurrent gliomas , 1995, The Lancet.

[3]  B. Wang,et al.  Functional design features and initial performance characteristics of a magnetic-implant guidance system for stereotactic neurosurgery , 1995, IEEE Transactions on Biomedical Engineering.

[4]  B. Wang,et al.  Characteristics of an improved magnetic-implant guidance system , 1995, IEEE Transactions on Biomedical Engineering.

[5]  Russell H. Taylor,et al.  An efficient needle injection technique and radiological guidance method for percutaneous procedures , 1997, CVRMed.

[6]  H Kalimo,et al.  Interstitial chemotherapy with carmustine-loaded polymers for high-grade gliomas: a randomized double-blind study. , 1997, Neurosurgery.

[7]  M A Howard,et al.  Experimental study of the magnetic stereotaxis system for catheter manipulation within the brain. , 2000, Journal of neurosurgery.

[8]  Witham,et al.  Comprehensive assessment of hemorrhage risks and outcomes after stereotactic brain biopsy. , 2001, Journal of neurosurgery.

[9]  Walter A Hall,et al.  Convection-enhanced delivery in clinical trials. , 2003, Neurosurgical focus.

[10]  Septimiu E. Salcudean,et al.  Needle insertion modeling and simulation , 2003, IEEE Trans. Robotics Autom..

[11]  S. Kunwar Convection enhanced delivery of IL13-PE38QQR for treatment of recurrent malignant glioma: presentation of interim findings from ongoing phase 1 studies. , 2003, Acta neurochirurgica. Supplement.

[12]  Manfred Westphal,et al.  A phase 3 trial of local chemotherapy with biodegradable carmustine (BCNU) wafers (Gliadel wafers) in patients with primary malignant glioma. , 2003, Neuro-oncology.

[13]  M. Berger,et al.  Progress Report of a Phase I Study of the Intracerebral Microinfusion of a Recombinant Chimeric Protein Composed of Transforming Growth Factor (TGF)-α and a Mutated form of the Pseudomonas Exotoxin Termed PE-38 (TP-38) for the Treatment of Malignant Brain Tumors , 2003, Journal of Neuro-Oncology.

[14]  Manfred Westphal,et al.  Perspectives of Cellular and Molecular Neurosurgery , 2004, Journal of Neuro-Oncology.

[15]  D. Kondziolka,et al.  Evaluation of Surgical Techniques for Neuronal Cell Transplantation Used in Patients with Stroke , 2004, Cell transplantation.

[16]  Barry W Wessels,et al.  Safety and Feasibility of Convection-enhanced Delivery of Cotara for the Treatment of Malignant Glioma: Initial Experience in 51 Patients , 2005, Neurosurgery.

[17]  Robert Rohling,et al.  Hand-held steerable needle device , 2003, IEEE/ASME Transactions on Mechatronics.

[18]  Jin Seob Kim,et al.  Nonholonomic Modeling of Needle Steering , 2006, Int. J. Robotics Res..

[19]  C.N. Riviere,et al.  Toward Effective Needle Steering in Brain Tissue , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[20]  B R Thomadsen,et al.  Observations on rotating needle insertions using a brachytherapy robot , 2007, Physics in medicine and biology.

[21]  Daniel Glozman,et al.  Image-Guided Robotic Flexible Needle Steering , 2007, IEEE Transactions on Robotics.

[22]  M. Budoff,et al.  National Institute of Neurological Disorders and Stroke , 2008 .

[23]  W. Hall,et al.  Convection-enhanced delivery: neurosurgical issues. , 2009, Current drug targets.