Experimental study on phase separation of refrigerant at horizontal T-junction

Abstract In this paper, the phase redistribution of refrigerant two-phase flow at a horizontal branch T-junction was investigated experimentally. The T-junction had equal-sized inlet and outlet tubes (internal diameter 8.0 mm). During the experiments, three refrigerants, namely R134a, R600a and R245fa were considered. The inlet mass flux and quality were varied from 200 to 500 kg m−2 s−1 and from 0.1 to 0.9, respectively. Meanwhile, the mass flux of the branch was regulated by keeping the mass flow ratios to 0.3, 0.5 and 0.7. Under these experimental conditions, intermittent and annular flows at the T-junction inlet were identified and predicted. After analyzing the experimental data, it was found that the vapor is preferred to flow into the branch. As the inlet quality increases, the fraction of vapor extracted into the branch decreases, whereas the mass flux has little influence on the phase redistribution of refrigerant under the same flow pattern. Furthermore, a higher vapor fraction can be obtained by a larger mass flow ratio. For the effect of refrigerant on the phase separation, the vapor faction of the branch satisfies the following order: R245fa > R600a > R134a. The product of momentum ratio and viscosity ratio between vapor and liquid is defined to characterize the phase separation degree of refrigerant qualitatively. In order to test the applicability of the published models in the literature, the present data are compared with the predicted values. The results show that the models for air-water are not appropriate to predict the phase redistribution of refrigerant two-phase flow at the T-junction. A separation model for refrigerant should be proposed by coupling with the pressure drop.

[1]  Richard T. Lahey,et al.  The analysis of phase separation phenomena in branching conduits , 1983 .

[3]  Elisabeth Mary Katie Wren,et al.  Geometric effects on phase split at a large diameter T-junction , 2001 .

[4]  A. Milosevic Flash gas bypass concept utilizing low pressure refrigerants , 2011 .

[5]  J.M.H. Fortuin,et al.  Phase distribution during gas—liquid flow through horizontal dividing junctions☆ , 1991 .

[6]  M. T. Rubel,et al.  Phase distribution during steam-water flow in a horizontal T-junction , 1988 .

[7]  Pega Hrnjak,et al.  Vapor–liquid separation in a vertical impact T-junction for vapor compression systems with flash gas bypass , 2014 .

[8]  Cristina Bertani,et al.  Two-Phase Flow in a Horizontal T - junction: Pressure Drop and Phase Separation , 2007 .

[9]  T. Miyazaki,et al.  Refrigerant distribution in horizontal headers with downward minichannel-branching conduits: Experiment, empirical correlation and two-phase flow pattern map , 2017 .

[10]  Ovadia Shoham,et al.  Two-phase stratified flow splitting at a T-jun , 1996 .

[11]  Keumnam Cho,et al.  Two-phase split of refrigerants at a T-junction , 2006 .

[12]  A.M.C. Chan,et al.  Steam-water annular flow in a horizontal dividing T-junnction , 1988 .

[13]  Jing Zhang,et al.  Experimental study on two-phase separation performance of impacting T-junction , 2016 .

[14]  Predrag Stojan Hrnjak,et al.  Flash gas bypass in mobile air conditioning system with R134a , 2012 .

[15]  J. Thome,et al.  Investigation of Flow Boiling in Horizontal Tubes: Part I, A New Diabatic Two-Phase Flow Pattern Map , 2005 .

[16]  Richard J Goldstein,et al.  An Experimental Study of Natural Convection Heat Transfer in Concentric and Eccentric Horizontal Cylindrical Annuli , 1978 .

[17]  H. M. Soliman,et al.  Two-phase pressure drop and phase distribution of a horizontal tee junction , 1994 .

[18]  Robert J. Moffat,et al.  Describing the Uncertainties in Experimental Results , 1988 .

[19]  Richard T. Lahey,et al.  Phase separation in dividing two-phase flows , 1988 .

[20]  B. J. Azzopardi,et al.  The effect of flow patterns on two-phase flow in a T junction , 1982 .

[21]  Denis Flick,et al.  Heat transfer by natural convection in domestic refrigerators , 2004 .

[22]  Barry J. Azzopardi,et al.  Plant Application of a T-Junction as a Partial Phase Separator , 2002 .

[23]  Thomas J. Hanratty,et al.  Entrainment for horizontal annular gas-liquid flow , 1984 .

[24]  L. C. Walters,et al.  Two-phase pressure drop and phase distribution at reduced tee junctions , 1998 .

[25]  Barry J. Azzopardi,et al.  The split of annular two-phase flow at a small diameter T-junction , 2000 .

[26]  J. Henry,et al.  DIVIDING ANNULAR FLOW IN A HORIZONTAL TEE , 1981 .

[27]  Pega Hrnjak,et al.  Enhancement of vapor–liquid separation in vertical impact T-junctions for vapor compression systems with flash gas bypass , 2014 .

[28]  J. Reimann,et al.  Two-phase flow in a T-junction with a horizontal inlet. Part II: Pressure differences , 1986 .

[29]  Barry J. Azzopardi,et al.  The split of stratified gas–liquid flow at a small diameter T-junction , 2005 .

[30]  Ovadia Shoham,et al.  Two-phase flow splitting in a tee junction—experiment and modelling , 1987 .

[31]  A. Dukler,et al.  A model for predicting flow regime transitions in horizontal and near horizontal gas‐liquid flow , 1976 .

[32]  J. Reimann,et al.  Two-phase flow in a T-junction with a horizontal inlet. Part I: Phase separation , 1986 .