Precise insertion of orthodontic miniscrews with a stereolithographic surgical guide based on cone beam computed tomography data: a pilot study.

PURPOSE Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereolithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. MATERIALS AND METHODS Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. RESULTS The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. CONCLUSIONS The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures.

[1]  Ilser Turkyilmaz,et al.  Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. , 2008, Journal of periodontology.

[2]  Yong-Suk Choi,et al.  Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[3]  B Giuliano Maino,et al.  Spider Screw: skeletal anchorage system. , 2005, Progress in orthodontics.

[4]  Kenji Takada,et al.  A stent fabricated on a selectively colored stereolithographic model for placement of orthodontic mini-implants. , 2002, The International journal of adult orthodontics and orthognathic surgery.

[5]  Jacob Rosen,et al.  Accuracy of implant placement using precision surgical guides with varying occlusogingival heights: an in vitro study. , 2009, The Journal of prosthetic dentistry.

[6]  M. Figl,et al.  Accuracy of Craniofacial Measurements: Computed Tomography and Three-Dimensional Computed Tomography Compared With Stereolithographic Models , 2008, The Journal of craniofacial surgery.

[7]  Gerald Nelson,et al.  Clinical application of a stereolithographic surgical guide for simple positioning of orthodontic mini-implants. , 2008, World journal of orthodontics.

[8]  Kunal Lal,et al.  Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept. , 2006, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[9]  Eliakim Mizrahi,et al.  Mini-Screw Implants (Temporary Anchorage Devices): Orthodontic and Pre-Prosthetic Applications , 2007, Journal of orthodontics.

[10]  Shouichi Miyawaki,et al.  Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. , 2003, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[11]  A. Tortamano,et al.  Surgical guide for optimal positioning of mini-implants. , 2005, Journal of clinical orthodontics : JCO.

[12]  S. Rosenstiel,et al.  Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[13]  Patricia R Cury,et al.  Clinical application of stereolithographic surgical guides for implant placement: preliminary results. , 2005, Journal of periodontology.

[14]  Eduardo Yugo Suzuki,et al.  Accuracy of miniscrew implant placement with a 3-dimensional surgical guide. , 2008, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[15]  Stephan Eitner,et al.  Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates. , 2007, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[16]  B. Kusnoto,et al.  Risks and complications of orthodontic miniscrews. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[17]  J. Cope,et al.  Miniscrew implants: IMTEC Mini Ortho Implants , 2005 .

[18]  Saad A Al-Harbi,et al.  Implant Placement Accuracy When Using Stereolithographic Template as a Surgical Guide: Preliminary Results , 2009, Implant dentistry.

[19]  Jörg Neugebauer,et al.  Accuracy of a newly developed integrated system for dental implant planning. , 2009, Clinical oral implants research.

[20]  B. Melsen,et al.  Miniscrew Implants: The Aarhus Anchorage System , 2005 .

[21]  Jae-Hyun Sung,et al.  Clinical application of micro-implant anchorage. , 2002, Journal of clinical orthodontics : JCO.

[22]  Chengtao Wang,et al.  Modular preoperative planning software for computer-aided oral implantology and the application of a novel stereolithographic template: a pilot study. , 2009, Clinical implant dentistry and related research.