An experimental protocol for the definition of upper limb anatomical frames on children using magneto-inertial sensors

Motion capture based on magneto-inertial sensors is a technology enabling data collection in unstructured environments, allowing “out of the lab” motion analysis. This technology is a good candidate for motion analysis of children thanks to the reduced weight and size as well as the use of wireless communication that has improved its wearability and reduced its obtrusivity. A key issue in the application of such technology for motion analysis is its calibration, i.e. a process that allows mapping orientation information from each sensor to a physiological reference frame. To date, even if there are several calibration procedures available for adults, no specific calibration procedures have been developed for children. This work addresses this specific issue presenting a calibration procedure for motion capture of thorax and upper limbs on healthy children. Reported results suggest comparable performance with similar studies on adults and emphasize some critical issues, opening the way to further improvements.

[1]  Hans-Peter Kriegel,et al.  A Density-Based Algorithm for Discovering Clusters in Large Spatial Databases with Noise , 1996, KDD.

[2]  P H Veltink,et al.  Ambulatory measurement of arm orientation. , 2007, Journal of biomechanics.

[3]  C. Von Hofsten,et al.  Perception-action in children with ASD , 2012, Front. Integr. Neurosci..

[4]  Robert E. Mahony,et al.  Nonlinear Complementary Filters on the Special Orthogonal Group , 2008, IEEE Transactions on Automatic Control.

[5]  Laura Rocchi,et al.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors , 2008, Medical & Biological Engineering & Computing.

[6]  Oliver Amft,et al.  ETHOS: Miniature orientation sensor for wearable human motion analysis , 2010, 2010 IEEE Sensors.

[7]  Domenico Formica,et al.  An alignment procedure for ambulatory measurements of lower limb kinematic using magneto-inertial sensors , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  Greg Welch,et al.  Motion Tracking: No Silver Bullet, but a Respectable Arsenal , 2002, IEEE Computer Graphics and Applications.

[9]  L. Zollo,et al.  Inter-hemispheric coupling changes associate with motor improvements after robotic stroke rehabilitation. , 2012, Restorative neurology and neuroscience.

[10]  John L. Crassidis,et al.  Survey of nonlinear attitude estimation methods , 2007 .

[11]  J. Duhamel,et al.  Differential effects of parietal and frontal inactivations on reaction times distributions in a visual search task , 2012, Front. Integr. Neurosci..

[12]  F C T van der Helm,et al.  Functionally interpretable local coordinate systems for the upper extremity using inertial & magnetic measurement systems. , 2010, Journal of biomechanics.

[13]  A. Cappozzo,et al.  A spot check for assessing static orientation consistency of inertial and magnetic sensing units. , 2011, Gait & posture.

[14]  Domenico Campolo,et al.  Inertial-Magnetic Sensors for Assessing Spatial Cognition in Infants , 2011, IEEE Transactions on Biomedical Engineering.

[15]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[16]  F. Keller,et al.  Sensor-based technology in the study of motor skills in infants at risk for ASD , 2012, 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[17]  Steven K. Charles,et al.  The passive stiffness of the wrist and forearm. , 2012, Journal of neurophysiology.

[18]  Sebastian Madgwick,et al.  Estimation of IMU and MARG orientation using a gradient descent algorithm , 2011, 2011 IEEE International Conference on Rehabilitation Robotics.

[19]  G. Rizzolatti,et al.  The functional role of the parieto-frontal mirror circuit: interpretations and misinterpretations , 2010, Nature Reviews Neuroscience.

[20]  E. Guglielmelli,et al.  A microfabricated flexible slip sensor , 2012, 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[21]  Paolo Dario,et al.  A slip sensor for biorobotic applications using a hot wire anemometry approach , 2012 .

[22]  Adriano Ferrari,et al.  ‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors , 2009, Medical & Biological Engineering & Computing.