ENERGETIC AND EXERGETIC ANALYSES OF CARBON DIOXIDE TRANSCRITICAL REFRIGERATION SYSTEMS FOR HOT CLIMATES

In the last two decades many scientific papers and reports have been published in the field of the application of the carbon dioxide as a refrigerant for refrigeration systems and heat pumps. Special attention has been paid to the transcritical cycle. However, almost no papers discussed such cycles for hot climates, i.e., when the temperature of the environment is higher than 40oС during a long period of time. This paper deals with the energetic and exergetic evaluation of a CO2 refrigeration system operating in a transcritical cycle under hot climatic conditions. The performance and exergy efficiency of the CO2 refrigeration system depend on the operation conditions. The effect of varying these conditions is also investigated as well as the limitations associated with these conditions.

[1]  Marco Corradi,et al.  Carbon dioxide as refrigerant for tap water heat pumps: A comparison with the traditional solution , 2005 .

[2]  G. Lorentzen Revival of carbon dioxide as a refrigerant , 1994 .

[3]  Jahar Sarkar,et al.  Transcritical CO2 heat pump systems: exergy analysis including heat transfer and fluid flow effects , 2005 .

[4]  David S.-K. Ting,et al.  Second law analysis of the transcritical CO2 refrigeration cycle , 2004 .

[5]  George Tsatsaronis,et al.  Recent developments in exergy analysis and exergoeconomics , 2008 .

[6]  Ryohei Yokoyama,et al.  Influence of ambient temperatures on performance of a CO2 heat pump water heating system , 2007 .

[7]  P. Nekså,et al.  CO2-heat pump water heater: characteristics, system design and experimental results , 1998 .

[8]  Kandadai Srinivasan,et al.  Exergetic analysis of carbon dioxide vapour compression refrigeration cycle using the new fundamental equation of state , 2003 .

[9]  Perry Sadorsky,et al.  Trade and energy consumption in the Middle East , 2011 .

[10]  K Klöcker,et al.  Applying the transcritical CO2 process to a drying heat pump , 1998 .

[11]  Friedrich Kauf,et al.  Determination of the optimum high pressure for transcritical CO2-refrigeration cycles , 1999 .

[12]  E. Bilgen,et al.  Exergy analysis and experimental study of heat pump systems , 2002 .

[13]  Jostein Pettersen,et al.  Fundamental process and system design issues in CO2 vapor compression systems , 2004 .

[14]  H. Auracher Thermal design and optimization , 1996 .

[15]  G. Tsatsaronis Definitions and nomenclature in exergy analysis and exergoeconomics , 2007 .

[16]  Henggen Shen,et al.  Theoretical and experimental studies on optimum heat rejection pressure for a CO2 heat pump system , 2010 .

[17]  Tatiana Morosuk,et al.  Advanced exergetic evaluation of refrigeration machines using different working fluids , 2009 .

[18]  Andy Pearson,et al.  ICR0021 CARBON DIOXIDE - NEW USES FOR AN OLD REFRIGERANT , 2005 .

[19]  Chi-Chuan Wang,et al.  Some design features of a CO2 air conditioner , 2001 .

[20]  T. J. Kotas,et al.  The Exergy Method of Thermal Plant Analysis , 2012 .

[21]  W. Fratzscher,et al.  The exergy method of thermal plant analysis , 1997 .

[22]  Petter Nekså,et al.  CO2 heat pump systems , 2002 .

[23]  W. Q. Tao,et al.  Exergetic analysis of transcritical CO2 residential air-conditioning system based on experimental data , 2010 .

[24]  J. Pettersen,et al.  A new, efficient and environmentally benign system for car air-conditioning , 1993 .

[25]  Reinhard Radermacher,et al.  Comparison of CO2 heat pump water heater performance with baseline cycle and two high COP cycles , 2010 .