A comparison of forearm and thumb muscle electromyographic responses to the use of laparoscopic instruments with either a finger grasp or a palm grasp.

Laparoscopic techniques allow for less-invasive treatment of common surgical problems. Laparoscopic instruments are different from standard surgical instruments and generally incorporate a pistol-grip handle configuration with rings for the fingers. This handle configuration has been reported as being uncomfortable, leading to finger compression neuropathies in some cases. As an alternative, the surgeon can choose to grasp laparoscopic instruments using a more powerful palm grip during grasping motions. This study evaluates the hypothesis that the use of the palm grip requires less muscle tension than the finger-grip when grasping with laparoscopic instruments. Nine general surgeons used an Autosuture laparoscopic grasper with a ringed pistol-grip handle held in both a finger-in-ring (F) or palm (P) hand grip position to grasp and close two spring-loaded metal plates. The same task was performed with a surgical haemostat clamp (H) for comparison. Each subject performed the grasping task in a random sequence for the three instrument configurations at two grasping forces levels (0.7 and 4.2 N), and with the instrument at three angles to the subjects' sagittal plane (0 degree, 45 degrees and 90 degrees). Surface electromyographic (EMG) signals were acquired from the flexor carpi ulnaris (FCU), flexor digitorum profundus (FDP), flexor digitorum superficialis (FDS), extensor carpi ulnaris (ECU), extensor digitorum comunis (EDC) and the thenar compartment (TH). The peak root mean squared (RMS) EMG voltage was averaged for five repetitions at each instrument, force and angle condition. Statistical analysis was carried out by repeated measures ANOVA. The muscle EMG RMS amplitude while using the palm grip was decreased in the FDS, TH and EDC, was unchanged in the ECU and FCU, and was slightly higher in the FDP when compared with the finger grip. These differences were most prominent at 90 degrees to the sagittal plane where the subjects' wrists neared maximal flexion. It is concluded that the palm grip is more powerful than the finger grip when grasping with laparoscopic instruments, particularly at angles perpendicular to the surgeon's sagittal plane.

[1]  A G Johnson,et al.  Laparoscopist's thumb: an occupational hazard. , 1993, Archives of surgery.

[2]  Lawrence Stark,et al.  Analysis of the surgeon's grasp for telerobotic surgical manipulation , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[3]  C. Long,et al.  Intrinsic-extrinsic muscle control of the hand in power grip and precision handling. An electromyographic study. , 1970, The Journal of bone and joint surgery. American volume.

[4]  David I. Watson,et al.  Laparoscopic surgeons' thumb-is it a training phenomenon? , 1997 .

[5]  L. Horgan,et al.  Neuropraxia following laparoscopic procedures: An occupational injury , 1997 .

[6]  Johnson Sl Ergonomic hand tool design. , 1993 .

[7]  Shulenberger Cc Ergonomics in the workplace: evaluating and modifying jobs. , 1992 .

[8]  Ramon Berguer,et al.  Laparoscopic instruments cause increased forearm fatigue: A subjective and objective comparison of open and laparoscopic techniques , 1997 .

[9]  E Fernström,et al.  Electromyographic activity during typewriter and keyboard use. , 1994, Ergonomics.

[10]  N Kano,et al.  Laparoscopic surgeon's thumb. , 1993, Archives of surgery.

[11]  U. Moritz,et al.  Occupational cervico-brachial disorders among dentists. Analysis of ergonomics and locomotor functions. , 1991, Swedish dental journal.

[12]  R Berguer,et al.  Ergonomics in the operating room. , 1996, American journal of surgery.

[13]  E. Milerad,et al.  Effects of precision and force demands, grip diameter, and arm support during manual work: an electromyographic study. , 1994, Ergonomics.

[14]  David L. Carr-Locke,et al.  National Institutes of Health consensus development conference statement: Gallstones and laparoscopic cholecystectomy September 14-16, 1992 (Final draft October 30, 1992) , 1993 .

[15]  M Patkin,et al.  Ergonomics, engineering and surgery of endosurgical dissection. , 1995, Journal of the Royal College of Surgeons of Edinburgh.

[16]  R. Berguer,et al.  An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparoscopic grasper , 1998, Surgical Endoscopy.