Evaluating the Hip Range of Motion Using the Goniometer and Video Tracking Methods

Abstract The hip joint's range of motion (ROM) is an important clinical parameter used in diagnosing femoroacetabular impingement (FAI). Along with the use of mechanical devices such as goniometers or inclinometers, motion capture and video tracking has been increasingly deployed to aid the hip joint diagnosis. The goniometer can simply measure the joint angles. However, it has some limitations on allowing the clinician to analyse the ROM at the gate and track the hip joint during walking or maximum squat. Motion capture devices are mainly used to analyse the patient's gait and assess the condition of the joints and bones. This study has used both motion capture and goniometer methods to examine the range of motion of three subject volunteers. The results of both methods have been compared and discussed. The results of the motion capture show flexion of 108±12, adduction (in 90° flexion) of 52±2 and internal rotation (in 90° flexion) of 28±2. For the goniometer results, measurements show flexion of 116±10, adduction (in 90° flexion) of 51±7 and internal rotation (in 90° flexion) of 36±2.

[1]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[2]  Frank Langlotz,et al.  Noninvasive three‐dimensional assessment of femoroacetabular impingement , 2007, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  Mario Lamontagne,et al.  Femoroacetabular impingement alters hip and pelvic biomechanics during gait Walking biomechanics of FAI. , 2009, Gait & posture.

[4]  S. Bierma-Zeinstra,et al.  Comparison between two devices for measuring hip joint motions , 1998, Clinical rehabilitation.

[5]  A. J. van den Bogert,et al.  Effect of skin movement on the analysis of skeletal knee joint motion during running. , 1997, Journal of biomechanics.

[6]  Heikki J Helminen,et al.  Physical function in men with and without hip osteoarthritis. , 2004, Archives of physical medicine and rehabilitation.

[7]  S B Murphy,et al.  Range of Motion in Anterior Femoroacetabular Impingement , 2007, Clinical orthopaedics and related research.

[8]  Lorenzo Chiari,et al.  Human movement analysis using stereophotogrammetry. Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics. , 2005, Gait & posture.

[9]  Nadia Magnenat-Thalmann,et al.  Motion study of the hip joint in extreme postures , 2009, The Visual Computer.

[10]  Mario Lamontagne,et al.  The Effect of Cam FAI on Hip and Pelvic Motion during Maximum Squat , 2009, Clinical orthopaedics and related research.

[11]  J. J. Gerhardt,et al.  Range-of-motion measurements. , 1995, The Journal of bone and joint surgery. American volume.

[12]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 1: theoretical background. , 2005, Gait & posture.

[13]  I. Holm,et al.  Reliability of goniometric measurements and visual estimates of hip ROM in patients with osteoarthrosis. , 2000, Physiotherapy research international : the journal for researchers and clinicians in physical therapy.

[14]  M. Harris-Hayes,et al.  Clinical Presentation of Patients with Symptomatic Anterior Hip Impingement , 2009, Clinical orthopaedics and related research.

[15]  R. Ganz,et al.  The Concept of Femoroacetabular Impingement: Current Status and Future Perspectives , 2009, Clinical orthopaedics and related research.

[16]  Paul Allard,et al.  Three-dimensional analysis of human movement , 1995 .

[17]  M. Leunig,et al.  Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients. , 2010, BMC musculoskeletal disorders.