Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy

Abstract Purpose The aim of this work was to comprehensively evaluate a new large field ion chamber transmission detector, Integral Quality Monitor (IQM), for online external photon beam verification and quality assurance. The device is designed to be mounted on the linac accessory tray to measure and verify photon energy, field shape, gantry position, and fluence before and during patient treatment. Methods Our institution evaluated the newly developed ion chamber's effect on photon beam fluence, response to dose, detection of photon fluence modification, and the accuracy of the integrated barometer, thermometer, and inclinometer. The detection of photon fluence modifications was performed by measuring 6 MV with fields of 10 cm × 10 cm and 1 cm × 1 cm “correct” beam, and then altering the beam modifiers to simulate minor and major delivery deviations. The type and magnitude of the deviations selected for evaluation were based on the specifications for photon output and MLC position reported in AAPM Task Group Report 142. Additionally, the change in ion chamber signal caused by a simulated IMRT delivery error is evaluated. Results The device attenuated 6 MV, 10 MV, and 15 MV photon beams by 5.43 ± 0.02%, 4.60 ± 0.02%, and 4.21 ± 0.03%, respectively. Photon beam profiles were altered with the IQM by < 1.5% in the nonpenumbra regions of the beams. The photon beam profile for a 1 cm × 1 cm2 fields were unchanged by the presence of the device. The large area ion chamber measurements were reproducible on the same day with a 0.14% standard deviation and stable over 4 weeks with a 0.47% SD. The ion chamber's dose–response was linear (R2 = 0.99999). The integrated thermometer agreed to a calibrated thermometer to within 1.0 ± 0.7°C. The integrated barometer agreed to a mercury barometer to within 2.3 ± 0.4 mmHg. The integrated inclinometer gantry angle measurement agreed with the spirit level at 0 and 180 degrees within 0.03 ± 0.01 degrees and 0.27 ± 0.03 at 90 and 270 degrees. For the collimator angle measurement, the IQM inclinometer agreed with a plum‐bob within 0.3 ± 0.2 degrees. The simulated IMRT error increased the ion chamber signal by a factor of 11–238 times the baseline measurement for each segment. Conclusions The device signal was dependent on variations in MU delivered, field position, single MLC leaf position, and nominal photon energy for both the 1 cm × 1 cm and 10 cm × 10 cm fields. This detector has demonstrated utility repeated photon beam measurement, including in IMRT and small field applications.

[1]  A consistency monitor for radiation therapy treatments. , 1996, Medical physics.

[2]  J. Wong Implementation of silicon based dosimeters, the dose magnifying glass and magic plate for the dosimetry of modulated radiation therapy , 2011 .

[3]  D. Jaffray,et al.  An integral quality monitoring system for real-time verification of intensity modulated radiation therapy. , 2009, Medical physics.

[4]  Young-Bin Cho,et al.  A method for online verification of adapted fields using an independent dose monitor. , 2013, Medical physics.

[5]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[6]  J. Tsai,et al.  Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients. , 1998, International journal of radiation oncology, biology, physics.

[7]  B. Fallone,et al.  Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system , 2002, Journal of applied clinical medical physics.

[8]  Fang-Fang Yin,et al.  Task Group 142 report: quality assurance of medical accelerators. , 2009, Medical physics.

[9]  B. Poppe,et al.  Clinical performance of a transmission detector array for the permanent supervision of IMRT deliveries. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  D. Cussans,et al.  The VANILLA sensor as a beam monitoring device for X-ray radiation therapy. , 2014, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[11]  M. C. Murillo,et al.  Dose calculation and verification of intensity modulation generated by dynamic multileaf collimators. , 2000, Medical physics.

[12]  Cedric X. Yu,et al.  Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. , 1995, Physics in medicine and biology.

[13]  F. Lohr,et al.  Patient-specific 3D pretreatment and potential 3D online dose verification of Monte Carlo-calculated IMRT prostate treatment plans. , 2011, International journal of radiation oncology, biology, physics.

[14]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[15]  L. Beaulieu,et al.  Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor. , 2011, Medical physics.

[16]  A L Boyer,et al.  Intensity-modulated radiation therapy with dynamic multileaf collimators. , 1999, Seminars in radiation oncology.

[17]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.

[18]  M. Petasecca,et al.  Characterization of a novel two dimensional diode array the "magic plate" as a radiation detector for radiation therapy treatment. , 2012, Medical physics.

[19]  L. Xing,et al.  Overview of image-guided radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[20]  Sasa Mutic,et al.  Process-based quality management for clinical implementation of adaptive radiotherapy. , 2014, Medical physics.

[21]  Ben Mijnheer,et al.  In vivo dosimetry in external beam radiotherapy. , 2013, Medical physics.

[22]  C. Thieke,et al.  DAVID—a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques , 2006, Physics in medicine and biology.

[23]  Investigation of the spatial resolution of an online dose verification device. , 2012, Medical physics.

[24]  J. Dempsey,et al.  Quantitative dosimetric verification of an IMRT planning and delivery system. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.