New Biofidelic Corridor and Biofidelity Test Procedure for Pedestrian Legform Impactors

The objectives of this research are to propose a new impact response corridor for the ISO legform impactor and to determine the biofidelity of the current legform impactor with rigid leg and thigh developed by the Transport Research Laboratory (TRL). The latest data obtained from Post Mortem Human Subject (PMHS) knee impact tests were analyzed in connection with the proposal, and biofidelity legform impact tests were conducted using the current rigid legform impactor. New normalized biofidelic corridors of impact force corresponding to adult male 50th percentile (AM50) are proposed. The impact test results indicate the current rigid legform impactor does not have sufficient human knee biofidelity. The present results suggest that human tolerance can not be used directly for the injury reference value of the legform impactor. A conversion method is needed to interpret the data measured by current legform impactors as the injury reference value.

[1]  Jason R. Kerrigan,et al.  Experiments for establishing pedestrian-impact lower limb injury criteria , 2003 .

[2]  Janusz Kajzer,et al.  Response of the knee joint in lateral impact: effect of shearing loads , 1990 .

[3]  Yasuhiro Matsui,et al.  Shearing and bending effects at the knee joint at high speed lateral loading , 1997 .

[4]  Rolf H. Eppinger,et al.  Development of dummy and injury index for NHTSA's thoracic side impact protection research program , 1984 .

[5]  D C Viano,et al.  Biomechanics of the human chest, abdomen, and pelvis in lateral impact. , 1989, Accident; analysis and prevention.

[6]  Yukou Takahashi,et al.  BIOFIDELITY OF TEST DEVICES AND VALIDITY OF INJURY CRITERIA FOR EVALUATING KNEE INJURIES TO PEDESTRIANS , 2001 .

[7]  Jason R. Kerrigan,et al.  EVALUATION OF THE RESPONSE OF MECHANICAL PEDESTRIAN KNEE JOINT IMPACTORS IN BENDING AND SHEAR LOADING , 2003 .

[8]  Y Takahashi,et al.  Development and validation of the finite element model for the human lower limb of pedestrians. , 2000, Stapp car crash journal.

[9]  David C. Viano,et al.  Biomechanical responses and injuries in blunt lateral impact , 1989 .

[10]  Janusz Kajzer,et al.  Response of the knee joint in lateral impact: effect of bending moment , 1993 .

[11]  Y Matsui Biofidelity of TRL Legform Impactor and Injury Tolerance of the Human Leg in Lateral Impact. , 2001, Stapp car crash journal.

[12]  Yasuhiro Matsui,et al.  Injury Pattern and Response of Human Thigh under Lateral Loading Simulating Car-Pedestrian Impact , 2004 .

[13]  Yasuhiro Matsui Evaluation of Pedestrian Subsystem Test Method Using Legform and Upper Legform Impactors for Assessment of High-Bumper Vehicle Aggressiveness , 2004, Traffic injury prevention.