Parameter variation effects on temperature elevation in a steady-state, one-dimensional thermal model for millimeter wave exposure of one- and three-layer human tissue

The present study describes theoretical parametric analysis of the steady-state temperature elevation in one-dimensional three-layer (skin, fat and muscle) and one-layer (skin only) models due to millimeter-wave exposure. The motivation of this fundamental investigation is that some variability of warmth sensation in the human skin has been reported. An analytical solution for a bioheat equation was derived by using the Laplace transform for the one-dimensional human models. Approximate expressions were obtained to investigate the dependence of temperature elevation on different thermal and tissue thickness parameters. It was shown that the temperature elevation on the body surface decreases monotonically with the blood perfusion rate, heat conductivity and heat transfer from the body to air. Also revealed were the conditions where maximum and minimum surface temperature elevations were observed for different thermal and tissue thickness parameters. The surface temperature elevation in the three-layer model is 1.3-2.8 times greater than that in the one-layer model. The main reason for this difference is attributed to the adiabatic nature of the fat layer. By considering the variation range of thermal and tissue thickness parameters which causes the maximum and minimum temperature elevations, the dominant parameter influencing the surface temperature elevation was found to be the heat transfer coefficient between the body surface and air.

[1]  H. H. Penns Analysis of tissue and arterial blood temperatures in the resting human forearm , 1948 .

[2]  T J Walters,et al.  Thresholds of microwave-evoked warmth sensations in human skin. , 1997, Bioelectromagnetics.

[3]  W. S. Snyder,et al.  Report of the task group on reference man , 1979, Annals of the ICRP.

[4]  J. Herbertz Comment on the ICNIRP guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998, Health physics.

[5]  S. Alekseev,et al.  Influence of blood flow and millimeter wave exposure on skin temperature in different thermal models , 2009, Bioelectromagnetics.

[6]  K. Lomas,et al.  A computer model of human thermoregulation for a wide range of environmental conditions: the passive system. , 1999, Journal of applied physiology.

[7]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[8]  H. Shirai,et al.  Theoretical Analysis for Temperature Elevation of Human Body Due to Millimeter Wave Exposure , 2008, 2008 Cairo International Biomedical Engineering Conference.

[9]  R. Leggett,et al.  Reference values for resting blood flow to organs of man. , 1989, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[10]  M C Ziskin,et al.  Local heating of human skin by millimeter waves: A kinetics study , 2003, Bioelectromagnetics.

[11]  Eleanor R. Adair,et al.  A thermal model for human thresholds of microwave-evoked warmth sensations , 1997 .

[12]  Akimasa Hirata,et al.  Correlation Between Peak Spatial-Average SAR and Temperature Increase Due to Antennas Attached to Human Trunk , 2006, IEEE Transactions on Biomedical Engineering.

[13]  Report of the task group on reference man ICRP Publication 23 (1975) , 1980 .

[14]  O. Gandhi,et al.  Temperature distributions in the human leg for VLF-VHF exposures at the ANSI-recommended safety levels , 1988, IEEE Transactions on Biomedical Engineering.

[15]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. 1948. , 1948, Journal of applied physiology.

[16]  Soichi Watanabe,et al.  Effects of dielectric permittivities on skin heating due to millimeter wave exposure , 2009, Biomedical engineering online.

[17]  A. Ahlbom Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998 .

[18]  K R Foster,et al.  Heating of tissues by microwaves: a model analysis. , 1998, Bioelectromagnetics.

[19]  M C Ziskin,et al.  Local heating of human skin by millimeter waves: Effect of blood flow , 2005, Bioelectromagnetics.