Accurate temperature model for absorptance determination of optical components with laser calorimetry.

In the international standard (International Organization for Standardization 11551) for measuring the absorptance of optical components (i.e., laser calorimetry), the absorptance is obtained by fitting the temporal behavior of laser irradiation-induced temperature rise to a homogeneous temperature model in which the infinite thermal conductivity of the sample is assumed. In this paper, an accurate temperature model, in which both the finite thermal conductivity and size of the sample are taken into account, is developed to fit the experimental temperature data for a more precise determination of the absorptance. The difference and repeatability of the results fitted with the two theoretical models for the same experimental data are compared. The optimum detection position when the homogeneous model is employed in the data-fitting procedure is also analyzed with the accurate temperature model. The results show that the optimum detection location optimized for a wide thermal conductivity range of 0.2-50W/m·K moves toward the center of the sample as the sample thickness increases and deviates from the center as the radius and irradiation time increase. However, if the detection position is optimized for an individual sample with known sample size and thermal conductivity by applying the accurate temperature model, the influence of the finite thermal conductivity and sample size on the absorptance determination can be fully compensated for by fitting the temperature data recorded at the optimum detection position to the homogeneous temperature model.

[1]  M. Sparks,et al.  Optical Distortion by Heated Windows in High-Power Laser Systems, , 1971 .

[2]  G Enrique Bernal Heat Flow Analysis of Laser Absorption Calorimetry , 1975 .

[3]  H. B. Rosenstock,et al.  Absorption measurements by laser calorimetry , 1979 .

[4]  A. Boccara,et al.  Sensitive photothermal deflection technique for measuring absorption in optically thin media. , 1980, Optics letters.

[5]  D. Ristau,et al.  Development of a thermographic laser calorimeter. , 1986, Applied optics.

[6]  P. Kuo,et al.  Single-beam interferometry of a thermal bump. , 1990, Applied optics.

[7]  Michael Reichling,et al.  Harmonic heat flow in isotropic layered systems and its use for thin film thermal conductivity measurements , 1994 .

[8]  H. Grönbeck,et al.  Harmonic heat flow in anisotropic thin films , 1995 .

[9]  Detlev Ristau,et al.  Calorimetric measurement of optical absorption at 532 nm and 1064 nm according to ISO/FDIS 11551 , 1996, Other Conferences.

[10]  E. Eva,et al.  Calorimetric measurement of two-photon absorption and color-center formation in ultraviolet-window materials , 1996 .

[11]  Detlev Ristau,et al.  Calorimetric measurement of optical absorption and transmissivity with sub-ppm sensitivity , 1996, Optical Systems Design.

[12]  U Willamowski,et al.  Measuring the absolute absorptance of optical laser components. , 1998, Applied optics.

[13]  S. Martin,et al.  Pulsed top-hat beam thermal-lens measurement for ultraviolet dielectric coatings. , 1999, Optics letters.

[14]  J R Taylor,et al.  Absorptance behavior of optical coatings for high-average-power laser applications. , 2000, Applied optics.

[15]  Holger Blaschke,et al.  Absorptance measurements for the DUV spectral range by laser calorimetry , 2003, SPIE Laser Damage.

[16]  Laurent Gallais,et al.  Photothermal deflection in multilayer coatings: modeling and experiment. , 2005, Applied optics.

[17]  Li Bincheng,et al.  Analysis of temperature and deformation fields in an optical coating sample , 2008 .

[18]  Siegfried Kufert,et al.  Characterization of low losses in optical thin films and materials. , 2008, Applied optics.