Current Trends in Intraoperative Spinal Cord Monitoring: A Survey Analysis among Japanese Expert Spine Surgeons

Introduction Although intraoperative spinal neuromonitoring (IONM) is recommended for spine surgeries, there are no guidelines regarding its use in Japan, and its usage is mainly based on the surgeon's preferences. Therefore, this study aimed to provide an overview of the current trends in IONM usage in Japan. Methods In this web-based survey, expert spine surgeons belonging to the Japanese Society for Spine Surgery and Related Research were asked to respond to a questionnaire regarding IONM management. The questionnaire covered various aspects of IONM usage, including the preferred modality, operation of IONM, details regarding muscle-evoked potential after electrical stimulation of the brain (Br(E)-MsEP), and need for consistent use of IONM in major spine surgeries. Results Responses were received from 134 of 186 expert spine surgeons (response rate, 72%). Of these, 124 respondents used IONM routinely. Medical staff rarely performed IONM without a medical doctor. Br(E)-MsEP was predominantly used for IONM. One-third of the respondents reported complications, such as bite injuries caused by Br(E)-MsEP. Interestingly, two-thirds of the respondents did not plan responses to alarm points. Intramedullary spinal cord tumor, scoliosis (idiopathic, congenital, or neuromuscular in pediatric), and thoracic ossification of the posterior longitudinal ligament were representative diseases that require IONM. Conclusions IONM has become an essential tool in Japan, and Br(E)-MsEP is a predominant modality for IONM at present. Although we investigated spine surgeries for which consistent use of IONM is supported, a cost-benefit analysis may be required.

[1]  Akimasa Yasuda,et al.  Efficacy of D-Wave Monitoring Combined With the Transcranial Motor-Evoked Potentials in High-Risk Spinal Surgery: A Retrospective Multicenter Study of the Monitoring Committee of the Japanese Society for Spine Surgery and Related Research , 2022, Global spine journal.

[2]  Suraj Sulhan,et al.  The utility of intraoperative neuromonitoring on simple posterior lumbar fusions-analysis of the National Inpatient Sample. , 2021, Journal of spine surgery.

[3]  H. Yamada,et al.  Intraoperative Spinal Cord Monitoring: Focusing on the Basic Knowledge of Orthopedic Spine Surgeon and Neurosurgeon as Members of a Team Performing Spine Surgery under Neuromonitoring , 2021, Spine surgery and related research.

[4]  P. Newton,et al.  Intraoperative neuromonitoring practice patterns in spinal deformity surgery: a global survey of the Scoliosis Research Society , 2020, Spine Deformity.

[5]  Akimasa Yasuda,et al.  Adverse Events Related to Transcranial Electric Stimulation for Motor-evoked Potential Monitoring in High-risk Spinal Surgery. , 2019, Spine.

[6]  A. Szelényi,et al.  Indication and technical implementation of the intraoperative neurophysiological monitoring during spine surgeries—a transnational survey in the German-speaking countries , 2019, Acta Neurochirurgica.

[7]  K. Shinomiya,et al.  What Is the Best Multimodality Combination for Intraoperative Spinal Cord Monitoring of Motor Function? A Multicenter Study by the Monitoring Committee of the Japanese Society for Spine Surgery and Related Research , 2015, Global spine journal.

[8]  J. Ratliff,et al.  Intraoperative Neuromonitoring in Single-Level Spinal Procedures: A Retrospective Propensity Score–Matched Analysis in a National Longitudinal Database , 2014, Spine.

[9]  Anand I. Rughani,et al.  A socioeconomic analysis of intraoperative neurophysiological monitoring during spine surgery: national use, regional variation, and patient outcomes. , 2014, Neurosurgical focus.

[10]  L. Lenke,et al.  Best Practices in Intraoperative Neuromonitoring in Spine Deformity Surgery: Development of an Intraoperative Checklist to Optimize Response , 2014, Spine deformity.

[11]  C. Yingling,et al.  Intraoperative motor evoked potential monitoring – A position statement by the American Society of Neurophysiological Monitoring , 2013, Clinical Neurophysiology.

[12]  Arvydas A Tamkus,et al.  The Incidence of Bite Injuries Associated with Transcranial Motor-Evoked Potential Monitoring , 2012, Anesthesia and analgesia.

[13]  Kai-Ming G. Fu,et al.  Complications in the Surgical Treatment of 19,360 Cases of Pediatric Scoliosis: A Review of the Scoliosis Research Society Morbidity and Mortality Database , 2011, Spine.

[14]  A. Sestokas,et al.  Transcranial Electric Motor Evoked Potential Monitoring During Spine Surgery: Is It Safe? , 2011, Spine.

[15]  H. Hall,et al.  Intraoperative spinal cord and nerve root monitoring: a survey of Canadian spine surgeons. , 2010, Canadian journal of surgery. Journal canadien de chirurgie.

[16]  Stuart R. Lipsitz,et al.  Effect of A 19-Item Surgical Safety Checklist During Urgent Operations in A Global Patient Population , 2010, Annals of surgery.

[17]  M. Fehlings,et al.  The Evidence for Intraoperative Neurophysiological Monitoring in Spine Surgery: Does It Make a Difference? , 2010, Spine.

[18]  Y. Matsuyama,et al.  Surgical results of intramedullary spinal cord tumor with spinal cord monitoring to guide extent of resection. , 2009, Journal of neurosurgery. Spine.

[19]  D. Grob,et al.  The diagnostic value of multimodal intraoperative monitoring (MIOM) during spine surgery: a prospective study of 1,017 patients , 2007, European Spine Journal.

[20]  R. Slappendel,et al.  Transcranial Electrical Motor-Evoked Potential Monitoring During Surgery for Spinal Deformity: A Study of 145 Patients , 2003, Spine.

[21]  D. Macdonald Safety of Intraoperative Transcranial Electrical Stimulation Motor Evoked Potential Monitoring , 2002, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[22]  L. Pelosi,et al.  Combined monitoring of motor and somatosensory evoked potentials in orthopaedic spinal surgery , 2002, Clinical Neurophysiology.

[23]  K. Shinomiya,et al.  A new alarm point of transcranial electrical stimulation motor evoked potentials for intraoperative spinal cord monitoring: a prospective multicenter study from the Spinal Cord Monitoring Working Group of the Japanese Society for Spine Surgery and Related Research. , 2014, Journal of neurosurgery. Spine.

[24]  R. Emerson,et al.  Risk factors for spinal cord injury during surgery for spinal deformity. , 2010, The Journal of bone and joint surgery. American volume.